988 resultados para Static volumetric method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The use of the family history method is recommended in family studies as a type of proxy interview of non-participating relatives. However, using different sources of information can result in bias as direct interviews may provide a higher likelihood of assigning diagnoses than family history reports. The aims of the present study were to: 1) compare diagnoses for threshold and subthreshold mood syndromes from interviews to those relying on information from relatives; 2) test the appropriateness of lowering the diagnostic threshold and combining multiple reports from the family history method to obtain comparable prevalence estimates to the interviews; 3) identify factors that influence the likelihood of agreement and reporting of disorders by informants. METHODS: Within a family study, 1621 informant-index subject pairs were identified. DSM-5 diagnoses from direct interviews of index subjects were compared to those derived from family history information provided by their first-degree relatives. RESULTS: 1) Inter-informant agreement was acceptable for Mania, but low for all other mood syndromes. 2) Except for Mania and subthreshold depression, the family history method provided significantly lower prevalence estimates. The gap improved for all other syndromes after lowering the threshold of the family history method. 3) Individuals who had a history of depression themselves were more likely to report depression in their relatives. LIMITATIONS: Low proportion of affected individuals for manic syndromes and lack of independence of data. CONCLUSIONS: The higher likelihood of reporting disorders by affected informants entails the risk of overestimation of the size of familial aggregation of depression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of the harmonic infrared frequency of diatomic molecules subjected to moderate static uniform electric fields is analysed. The potential energy expression has been developed as a function of a static uniform electric field, which brings about a formulation describing the frequency versus field strength curve. With the help of the first and second derivatives of the expressions obtained, which correspond to the first- and second-order Stark effects, it was possible to find the maxima of the frequency versus field strength curves for a series of molecules using a Newton-Raphson search. A method is proposed which requires only the calculation of a few energy derivatives at a particular value of the field strength. At the same time, the expression for the dependence of the interatomic distance on the electric field strength is derived and the minimum of this curve is found for the same species. Derived expressions and numerical results are discussed and compared with other studi

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatin immunoprecipitation followed by deep sequencing (ChIP-seq) experiments are widely used to determine, within entire genomes, the occupancy sites of any protein of interest, including, for example, transcription factors, RNA polymerases, or histones with or without various modifications. In addition to allowing the determination of occupancy sites within one cell type and under one condition, this method allows, in principle, the establishment and comparison of occupancy maps in various cell types, tissues, and conditions. Such comparisons require, however, that samples be normalized. Widely used normalization methods that include a quantile normalization step perform well when factor occupancy varies at a subset of sites, but may miss uniform genome-wide increases or decreases in site occupancy. We describe a spike adjustment procedure (SAP) that, unlike commonly used normalization methods intervening at the analysis stage, entails an experimental step prior to immunoprecipitation. A constant, low amount from a single batch of chromatin of a foreign genome is added to the experimental chromatin. This "spike" chromatin then serves as an internal control to which the experimental signals can be adjusted. We show that the method improves similarity between replicates and reveals biological differences including global and largely uniform changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realistic rendering animation is known to be an expensive processing task when physically-based global illumination methods are used in order to improve illumination details. This paper presents an acceleration technique to compute animations in radiosity environments. The technique is based on an interpolated approach that exploits temporal coherence in radiosity. A fast global Monte Carlo pre-processing step is introduced to the whole computation of the animated sequence to select important frames. These are fully computed and used as a base for the interpolation of all the sequence. The approach is completely view-independent. Once the illumination is computed, it can be visualized by any animated camera. Results present significant high speed-ups showing that the technique could be an interesting alternative to deterministic methods for computing non-interactive radiosity animations for moderately complex scenarios

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosis of several neurological disorders is based on the detection of typical pathological patterns in the electroencephalogram (EEG). This is a time-consuming task requiring significant training and experience. Automatic detection of these EEG patterns would greatly assist in quantitative analysis and interpretation. We present a method, which allows automatic detection of epileptiform events and discrimination of them from eye blinks, and is based on features derived using a novel application of independent component analysis. The algorithm was trained and cross validated using seven EEGs with epileptiform activity. For epileptiform events with compensation for eyeblinks, the sensitivity was 65 +/- 22% at a specificity of 86 +/- 7% (mean +/- SD). With feature extraction by PCA or classification of raw data, specificity reduced to 76 and 74%, respectively, for the same sensitivity. On exactly the same data, the commercially available software Reveal had a maximum sensitivity of 30% and concurrent specificity of 77%. Our algorithm performed well at detecting epileptiform events in this preliminary test and offers a flexible tool that is intended to be generalized to the simultaneous classification of many waveforms in the EEG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline whole-blood values due to processing and concentration. PRP is used in various surgical fields to enhance soft-tissue and bone healing by delivering supra-physiological concentrations of autologous platelets at the site of tissue damage. These preparations may provide a good cellular source of various growth factors and cytokines, and modulate tissue response to injury. Common clinically available materials for blood preparations combined with a two-step centrifugation protocol at 280g each, to ensure cellular component integrity, provided platelet preparations which were concentrated 2-3 fold over total blood values. Costs were shown to be lower than those of other methods which require specific equipment and high-cost disposables, while safety and traceability can be increased. PRP can be used for the treatment of wounds of all types including burns and also of split-thickness skin graft donor sites, which are frequently used in burn management. The procedure can be standardized and is easy to adapt in clinical settings with minimal infrastructure, thus enabling large numbers of patients to benefit from a form of cellular therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An adaptation technique based on the synoptic atmospheric circulation to forecast local precipitation, namely the analogue method, has been implemented for the western Swiss Alps. During the calibration procedure, relevance maps were established for the geopotential height data. These maps highlight the locations were the synoptic circulation was found of interest for the precipitation forecasting at two rain gauge stations (Binn and Les Marécottes) that are located both in the alpine Rhône catchment, at a distance of about 100 km from each other. These two stations are sensitive to different atmospheric circulations. We have observed that the most relevant data for the analogue method can be found where specific atmospheric circulation patterns appear concomitantly with heavy precipitation events. Those skilled regions are coherent with the atmospheric flows illustrated, for example, by means of the back trajectories of air masses. Indeed, the circulation recurrently diverges from the climatology during days with strong precipitation on the southern part of the alpine Rhône catchment. We have found that for over 152 days with precipitation amount above 50 mm at the Binn station, only 3 did not show a trajectory of a southerly flow, meaning that such a circulation was present for 98% of the events. Time evolution of the relevance maps confirms that the atmospheric circulation variables have significantly better forecasting skills close to the precipitation period, and that it seems pointless for the analogue method to consider circulation information days before a precipitation event as a primary predictor. Even though the occurrence of some critical circulation patterns leading to heavy precipitation events can be detected by precursors at remote locations and 1 week ahead (Grazzini, 2007; Martius et al., 2008), time extrapolation by the analogue method seems to be rather poor. This would suggest, in accordance with previous studies (Obled et al., 2002; Bontron and Obled, 2005), that time extrapolation should be done by the Global Circulation Model, which can process atmospheric variables that can be used by the adaptation method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Laparoscopic techniques have been proposed as an alternative to open surgery for therapy of peptic ulcer perforation. They provide better postoperative comfort and absence of parietal complications, but leakage occurs in 5% of cases. We describe a new method combining laparoscopy and endoluminal endoscopy, designed to ensure complete closure of the perforation. METHODS: Six patients with anterior ulcer perforations (4 duodenal, 2 gastric) underwent a concomitant laparoscopy and endoluminal endoscopy with closure of the orifice by an omental plug attracted into the digestive tract. RESULTS: All perforations were sealed. The mean operating time was 72 minutes. The mean hospital stay was 5.5 days. There was no morbidity and no mortality. At the 30-day evaluation all ulcers but one (due to Helicobacter pylori persistence) were healed. CONCLUSIONS: This method is safe and effective. Its advantages compared with open surgery or laparoscopic patching as well as its cost-effectiveness should be studied in prospective randomized trials.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytic method to evaluate nuclear contributions to electrical properties of polyatomic molecules is presented. Such contributions control changes induced by an electric field on equilibrium geometry (nuclear relaxation contribution) and vibrational motion (vibrational contribution) of a molecular system. Expressions to compute the nuclear contributions have been derived from a power series expansion of the potential energy. These contributions to the electrical properties are given in terms of energy derivatives with respect to normal coordinates, electric field intensity or both. Only one calculation of such derivatives at the field-free equilibrium geometry is required. To show the useful efficiency of the analytical evaluation of electrical properties (the so-called AEEP method), results for calculations on water and pyridine at the SCF/TZ2P and the MP2/TZ2P levels of theory are reported. The results obtained are compared with previous theoretical calculations and with experimental values

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Lunney Scoring Method for Rating Accuracy of Nursing Diagnoses (LSM) é uma escala de diferencial semântico que foi desenvolvida por Lunney para estimar a acurácia dos diagnósticos de enfermagem. O objetivo deste estudo foi adaptar o LSM para a língua portuguesa e avaliar as sua propriedades psicométricas. A escala original foi traduzida para o português, revertida para o inglês e as duas versões em inglês foram comparadas para ajustar a versão em português que passou a ser denominada Escala de Acurácia de Diagnóstico de Enfermagem de Lunney - EADE. Quatro enfermeiras foram orientadas sobre a EADE e a aplicaram em 159 diagnósticos formulados para 26 pacientes de três estudos primários com base nos registros de entrevista e exame físico de cada paciente. Os índices Kappa de Cohen mostraram ausência de concordância entre as avaliadoras, o que indica que o instrumento adaptado não tem confiabilidade satisfatória. Em virtude desse resultado, não foi realizada estimativa de validade.