955 resultados para Small Hydroeletric Power Plants
Resumo:
The Cerrado has been the main source of firewood and charcoal in Brazil, but despite being one of the hot spots for conservation of the world's biodiversity, neither plantations of native species nor sustainable management has been adopted in the region. The aim of this work was to investigate the biomass distribution and the potential for energy production of the cerrado species. The study was conducted in a cerrado sensu stricto site at the Água Limpa Farm (15º 56'14'' S and 47º 46'08'' W) in the Cerrado Biosphere Reserve. An area of 63.54ha was divided in 20 x 50m plots and, a random sample consisting of ten of these plots, representing 1.56% of the study-site, was assessed. All woody individuals from 5 cm diameter at 30 cm above ground level were identified and measured. Each individual was felled, the twigs thinner than 3cm were discarded while the larger branches and the trunks, both with bark, were weighted separately. After that, 2.5cm transverse sections of the trunk with bark were taken at 0, 25, 50, 75 and 100% of the length. A similar sample was also taken at the base of each branch. A total of 47 species in 35 genera and 24 families were found, with an average density of 673 individuals per ha. The diameter distribution showed a reversed-J shape with 67% of the individuals up to 13cm, while the maximum diameter was 32.30cm. Seven species represented 72% of the total biomass. In general, the species with higher production per tree were among those with higher production per ha. This content was distributed by diameter classes, reaching a maximum of 2.5ton/ha between 9 to 13cm and then, decreasing to 0.96 ton/ha between 29 to 33cm diameter. Carbon sequestering was 6.2ton/ha (until the actual stage of cerrado) based on an average 50% carbon content in the dry matter. The heat combustion of the wood varied from 18,903kj/kg to 20,888kj/kg with an average of 19,942kj/kg. The smaller diameter classes fix more carbon due to the large number of small plants per ha. But, for a species that reached larger dimensions and contained individuals in all diameter classes, Vochysia thyrsoidea, one can verify an increase in carbon fixation from 1.41 kg/ha in the first class (5 to 9cm) to 138,3kg/ha in the last (25 to 33cm). That indicates that it is possible to select species that reach larger size with a higher capacity of carbon accumulation per plant. The species that reached larger dimensions, with a production per tree above average and had high calorific power values were Dalbergia miscolobium, Pterodon pubescens and Sclerolobium paniculatum. These species have potential for use in fuelwood plantations and sustainable management.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
ABSTRACT The successful in the implementation of wind turbines depends on several factors, including: the wind resource at the installation site, the equipment used, project acquisition and operational costs. In this paper, the production of electricity from two small wind turbines was compared through simulation using the computer software HOMER - a national model of 6kW and an imported one of 5kW. The wind resources in three different cities were considered: Campinas (SP/BR), Cubatão (São Paulo/BR) and Roscoe (Texas/ USA). A wind power system connected to the grid and a wind isolated system - batteries were evaluated. The results showed that the energy cost ($/kWh) is strongly dependent on the windmill characteristics and local wind resource. Regarding the isolated wind system – batteries, the full supply guarantee to the simulated electrical load is only achieved with a battery bank with many units and high number of wind turbines, due to the intermittency of wind power.
Resumo:
The economic importance of small and medium-sized enterprises (SMEs) and entrepreneurship has increased significantly in recent decades and entrepreneurial activity and SMEs are deemed vital to economic progress. Therefore, it is justifiable to study how small firms and entrepreneurs can enhance their performance and emergence in the turbulent economic environment. The concept of entrepreneurial orientation (EO) has recently attracted considerable attention in the field of entrepreneurship research. EO generally refers to a firm’s propensity to be innovative, to be proactive and to take risks. A majority of EO studies so far have found that adopting EO associated entrepreneurial behaviors will help firms to create or sustain a high level of performance. This dissertation explores the main drivers and performance implications of EO for SMEs in time of economic crisis. Hence the first objective of this dissertation is to examine the performance implications of EO and to test the role of EO on how firms are treated by the crisis at operative level. The second objective is to expand the prevailing understanding of determinants of EO by exploring the relationship between owner's work related values, attitudes, demographic characteristics, firm’s financial resources and EO. EO was found to be a significant and positive factor behind a firm’s long run growth. Hence it can be said that EO has positive implications for firm performance. But on the other hand, during a time of economic crisis the different dimensions of EO had both positive and negative effects on performance of SMEs. The performance implications varied across different stages of the crisis and were also dependent on what measure was used for measuring the performance. The main drivers of EO in SMEs were the personal work related values of the entrepreneur and his/her prior experience as an entrepreneur. The intrinsic work values related to interest, responsibility, challenge, self-development or intellectual stimulation and values related to status, power, achievement and recognition had a positive effect on the level of EO. On the other hand, extrinsic values related to high income, material possessions, benefits such as generous holidays, job security, and comfort through good working conditions decreased the level of EO
Resumo:
This thesis presents a one-dimensional, semi-empirical dynamic model for the simulation and analysis of a calcium looping process for post-combustion CO2 capture. Reduction of greenhouse emissions from fossil fuel power production requires rapid actions including the development of efficient carbon capture and sequestration technologies. The development of new carbon capture technologies can be expedited by using modelling tools. Techno-economical evaluation of new capture processes can be done quickly and cost-effectively with computational models before building expensive pilot plants. Post-combustion calcium looping is a developing carbon capture process which utilizes fluidized bed technology with lime as a sorbent. The main objective of this work was to analyse the technological feasibility of the calcium looping process at different scales with a computational model. A one-dimensional dynamic model was applied to the calcium looping process, simulating the behaviour of the interconnected circulating fluidized bed reactors. The model incorporates fundamental mass and energy balance solvers to semi-empirical models describing solid behaviour in a circulating fluidized bed and chemical reactions occurring in the calcium loop. In addition, fluidized bed combustion, heat transfer and core-wall layer effects were modelled. The calcium looping model framework was successfully applied to a 30 kWth laboratory scale and a pilot scale unit 1.7 MWth and used to design a conceptual 250 MWth industrial scale unit. Valuable information was gathered from the behaviour of a small scale laboratory device. In addition, the interconnected behaviour of pilot plant reactors and the effect of solid fluidization on the thermal and carbon dioxide balances of the system were analysed. The scale-up study provided practical information on the thermal design of an industrial sized unit, selection of particle size and operability in different load scenarios.
Resumo:
This bachelor's thesis is about to find out to what extent Finnish managers and small and medium sized organizations are willing and able to put employee empowerment into practice and what experiences they have got from employee empowerment as an approach towards job redesign. Some of the top enterprises in the world are known for their empowered employees as a single most important factor for their success and this thesis focuses on introducing the subject to Finnish managers and organizations to find out what benefits, barriers and other thoughts they have about the whole idea of empowered employees in Finnish organization culture. Most notable findings in this thesis are that Finnish managers do think that their organization's employees are capable to work efficiently if their job is extended and the organizations would perform better when right person's job is enriched and he/she is given more power to solve problems.
Resumo:
The objective of this study was to evaluate glyphosate translocation in glyphosate-tolerant weed species (I. nil, T. procumbens and S. latifolia) compared to glyphosate-susceptible species (B. pilosa). The evaluations of 14C-glyphosate absorption and translocation were performed at 6, 12, 36 and 72 hours after treatment (HAT) in I. nil and B. pilosa, and only at 72 HAT in the species T. procumbens and S. latifolia. The plants were collected and fractionated into application leaf, other leaves, stems, and roots. In S. latifolia, approximately 88% of the glyphosate remained in the application leaf and a small amount was translocated to roots at 72 HAT. However, 75% of the herbicide applied on T. procumbens remained in the leaf that had received the treatment, with greater glyphosate translocation to the floral bud. It was concluded that the smaller amount of glyphosate observed in S. latifolia and T. procumbens may partly account for their higher tolerance to glyphosate. However, I. nil tolerance to glyphosate may be associated with other factors such as metabolization, root exudation or compartmentalization, because a large amount of the herbicide reached the roots of this species.
Resumo:
The experiment was carried out aiming to analyze the dry mass production and distribution and the content and accumulation of macronutrients in sourgrass (Digitaria insularis) plants cultivated under mineral nutrition standard conditions. Plants grew in 7-liter pots filled with sand substrate and daily irrigated with nutrient solution, being maintained under greenhouse conditions. Treatments consisted of times of evaluation (21, 35, 49, 63, 77, 91, 105, 119, and 133 days after emergence - DAE) and were arranged in a completely randomized design with four replicates. Sourgrass showed small accumulation of dry mass (0.3 g per plant) and macronutrients (3.7 mg of N per plant, 0.4 mg of P per plant, 5.6 mg of K per plant, 0.9 mg of Ca per plant, 0.7 mg of Mg per plant, and 0.3 mg of S per plant) at vegetative growth stage (< 49 DAE). Those accumulations increased mainly after 77 DAE, reaching the maximum theoretical value at 143, 135, 141, 129, 125, 120, and 128 DAE, for dry mass (12.4 g per plant), N (163.2 mg per plant), P (27.1 mg per plant), K (260.5 mg per plant), Ca (47.6 mg per plant), Mg (30.9 mg per plant), and S (13.7 mg per plant), respectively. K and N were found with higher rates and, as a consequence, they were required and accumulated in greater amounts in plant tissues of sourgrass.
Resumo:
Tässä diplomityössä tutkittiin vaihtoehtoja tehoelektroniikkalaitteiden kotelointiluokan kehittämiseksi. Haasteena paremman suojauksen suunnittelussa on laitteiden tuottama suuri määrä lämpöä, joka vaatii tehokkaan jäähdytyksen. Työn tuloksena saatu prototyyppi IP33 luokkaa varten täyttää standardissa SFS-EN 60529+A1 asetetut vaatimukset kyseiselle kotelointiluokalle. Rakenteessa ja valmistettavuudessa havaittiin muutama ongelma, jotka ovat korjattavissa pienillä muutoksilla. Korkeampia suojausluokkia varten testattiin IP54-luokiteltujen filtterituulettimien vaikutusta laitteen jäähdytykseen. Testien perusteella jäähdytysteho on riittävä ja filtterituulettimet todettiin toimivaksi ratkaisuksi korkeammille suojausluokille. Työn perusteella voidaan todeta, että nykyiset laitteet voidaan muokata vastaamaan IP33 luokan vaatimuksia kohtuullisen pienillä muutoksilla. Tätä korkeammat suojausluokat vaatisivat niin suuria muutoksia designiin, että todennäköisesti täysin uuden laitteen suunnittelu olis kannattavin vaihtoehto.
Resumo:
In this report, information is published concerning Russian water and wastewater treatment plants. The information is based on a questionnaire sent to 70 water and wastewater treatment plants in 2012-2013. The questionnaire was prepared by the International Advanced Water Technologies Centre (IAWTC) and Lahti Development Company (LADEC). The questions dealt with an assessment of the present state, the need for changes, renovation, investments, and how to improve the efficiency of the operation by training and investments. A significant need to renew the old pipelines, constructions, and processes was clearly evident. The aggregated answers can be utilized in Russia as internal benchmarking in order to arrange training and plant visits, which were requested in many of the answers. Sharing this open report with the respondents can aid networking and awareness of HELCOM requirements which relate to waste water treatment plants discharging their waste water directly or indirectly into the Baltic Sea. The aim of this report is to provide information for Finnish small and medium size companies (SMEs) as regards possible water related exportation to different parts of Russia.
Resumo:
The purpose of this Thesis is to find the most optimal heat recovery solution for Wärtsilä’s dynamic district heating power plant considering Germany energy markets as in Germany government pays subsidies for CHP plants in order to increase its share of domestic power production to 25 % by 2020. Different heat recovery connections have been simulated dozens to be able to determine the most efficient heat recovery connections. The purpose is also to study feasibility of different heat recovery connections in the dynamic district heating power plant in the Germany markets thus taking into consideration the day ahead electricity prices, district heating network temperatures and CHP subsidies accordingly. The auxiliary cooling, dynamical operation and cost efficiency of the power plant is also investigated.
Resumo:
Nowadays the energy efficiency has become one of the most concerned topics. Compressors are the equipment, which is very common in industry. Moreover, they tend to operate during long cycles and therefore even small decrease in power consumption can significantly reduce electricity costs during the year. And therefore it is important to investigate ways of increasing the energy efficiency of the compressors. In the thesis rotary screw compressor alongside with different control approaches is described. Simulation models for various control types of rotary screw compressor are developed. Analysis of laboratory equipment is conducted and results are compared with simulation. Suggestions of the real laboratory equipment improvement are given.
Resumo:
The main objective of the study was to define the methodology for assessing the limits for application island grids instead of interconnecting with existing grid infrastructure. The model for simulation of grid extension distance and levelised cost of electricity has been developed and validated by the case study in Finland. Thereafter, sensitivities of the application limits were examined with the respect to operational environment, load conditions, supply security and geographical location. Finally, recommendations for the small-scale rural electrification projects in the market economy environment have been proposed.
Resumo:
This thesis is done as a part of the NEOCARBON project. The aim of NEOCARBON project is to study a fully renewable energy system utilizing Power-to-Gas or Power-to-Liquid technology for energy storage. Power-to-Gas consists of two main operations: Hydrogen production via electrolysis and methane production via methanation. Methanation requires carbon dioxide and hydrogen as a raw material. This thesis studies the potential carbon dioxide sources within Finland. The different sources are ranked using the cost and energy penalty of the carbon capture, carbon biogenity and compatibility with Power-to-Gas. It can be concluded that in Finland there exists enough CO2 point sources to provide national PtG system with sufficient amounts of carbon. Pulp and paper industry is single largest producer of biogenic CO2 in Finland. It is possible to obtain single unit capable of grid balancing operations and energy transformations via Power-to-Gas and Gas-to-Power by coupling biogas plants with biomethanation and CHP units.
Resumo:
Energiantuotannossa syntyvä tuhka voi olla laadultaan hyvin vaihtelevaa ja laadunvaihtelulle on haastavaa löytää yksiselitteistä syy-seuraussuhdetta. Ympäristönsuojelulainsäädäntö ja taloudelliset intressit ohjaavat tuhkantuottajia etsimään tuhkalle sopivia hyötykäyttökohteita, ja sen vuoksi tuhkan laatuun ja hyötykäyttökelpoisuuteen vaikuttavia tekijöitä on tarpeen selvittää. Tässä diplomityössä on tutkittu pienissä, alle 50 MW:n polttolaitoksissa syntyvää tuhkaa. Tavoitteena oli selvittää, kuinka tuhkan hyötykäyttökelpoisuuteen voidaan vaikuttaa. Tutkimuksen kohteena oli polttoainekoostumuksen, poltto-olosuhteiden ja tuhkan jälkikäsittelyn vaikutus tuhkassa olevien haitta-aineiden pitoisuuksiin ja liukoisuuksin. Työhön sisältyi myös aiemmin tehtyjen tuhka-analyysien tarkastelu sekä tuhkakokeet kahdella kohderyhmään kuuluvalla laitoksella. Työssä todettiin lentotuhkan haitta-ainepitoisuuksien ja -liukoisuuksien olevan keskimäärin korkeampia kuin pohjatuhkan vastaavien, ja että tyypillisesti arinakattilan tuhkien haitta-aineet ylittävät useammin hyötykäyttökelpoisuuden raja-arvoja kuin kuplaleijupetikattilan tuhkien. Lisäksi havaittiin metsätähdehaketuhkan kelpaavan useammin hyötykäyttöön kuin rankahaketuhkan.