998 resultados para Similarity test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of the present study were 1) to compare results obtained by the traditional manual method of measuring heart rate (HR) and heart rate response (HRR) to the Valsalva maneuver, standing and deep breathing, with those obtained using a computerized data analysis system attached to a standard electrocardiograph machine; 2) to standardize the responses of healthy subjects to cardiovascular tests, and 3) to evaluate the response to these tests in a group of patients with diabetes mellitus (DM). In all subjects (97 healthy and 143 with DM) we evaluated HRR to deep breathing, HRR to standing, HRR to the Valsalva maneuver, and blood pressure response (BPR) to standing up and to a sustained handgrip. Since there was a strong positive correlation between the results obtained with the computerized method and the traditional method, we conclude that the new method can replace the traditional manual method for evaluating cardiovascular responses with the advantages of speed and objectivity. HRR and BPR of men and women did not differ. A correlation between age and HRR was observed for standing (r = -0.48, P<0.001) and deep breathing (r = -0.41, P<0.002). Abnormal BPR to standing was usually observed only in diabetic patients with definite and severe degrees of autonomic neuropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Post-training intracerebroventricular administration of procaine (20 µg/µl) and dimethocaine (10 or 20 µg/µl), local anesthetics of the ester class, prolonged the latency (s) in the retention test of male and female 3-month-old Swiss albino mice (25-35 g body weight; N = 140) in the elevated plus-maze (mean ± SEM for 10 male mice: control = 41.2 ± 8.1; procaine = 78.5 ± 10.3; 10 µg/µl dimethocaine = 58.7 ± 12.3; 20 µg/µl dimethocaine = 109.6 ± 5.73; for 10 female mice: control = 34.8 ± 5.8; procaine = 55.3 ± 13.4; 10 µg/µl dimethocaine = 59.9 ± 12.3 and 20 µg/µl dimethocaine = 61.3 ± 11.1). However, lidocaine (10 or 20 µg/µl), an amide class type of local anesthetic, failed to influence this parameter. Local anesthetics at the dose range used did not affect the motor coordination of mice exposed to the rota-rod test. These results suggest that procaine and dimethocaine impair some memory process(es) in the plus-maze test. These findings are interpreted in terms of non-anesthetic mechanisms of action of these drugs on memory impairment and also confirm the validity of the elevated plus-maze for the evaluation of drugs affecting learning and memory in mice

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antikens judiska bibeltolkare hade ett annorlunda sätt att läsa Bibeln än den som moderna läsare är vana vid. Dessa tidiga exegeter tänkte att texten som nu finns i den hebreiska Bibeln, de kristnas Gamla Testamente, är helig ordagrant i den form som den fanns i under deras tid, att den inte innehåller några fel, och att Gud har en övergripande plan gällande helheten, så att man vid behov kan förklara ett Bibelställe med hjälp av ett annat. Dessa antaganden reflekteras i det sätt på vilket antikens exegeter läste och tolkade sin Bibel. Det här ser man då man läser deras texter, från 400-talet före vår tideräknings början till de första århundradena enligt vår tideräkning. Ett verktyg som antikens skrifttolkare ofta använde var den så kallade gezera shava -metoden, där de jämförde identiska ord och fraser i Bibeln för att skänka belysning åt oklara textställen. Hebreiskan, särskilt den ovokaliserade konsonanttexten, innehåller många homonyma ord, alltså ord som ser likadana ut men har olika betydelser. De tidiga exegeterna utnyttjade ofta de möjligheter till alternativa tolkningar som uppstår ur denna tvetydighet. Ibland kunde de dock tvärtom också dra paralleller ur kontextuella likheter, alltid efter behov. I denna avhandling står dessa tidiga anonyma bibeltolkare och deras tolkningar i fokus. Malakis bok, som härstammar från ca år 475 f.v.t., kan ses som ett viktigt tidigt exempel på denna tendens till nytolkning av traditioner. Boken själv har dock också blivit föremål till nytolkningar, redan i de tilläggsverser som finns i dess slut, men särskilt i senare judisk litteratur och i Nya Testamentet. I avhandlingen granskas de fem bibliska gestalter som nämns i Malaki: Jakob, Esau, Levi, Mose och Elia. Hur används de i boken och hur har senare traditioner som anknyter till dem influerats av Malaki? ------------------------------------------------ Antiikin juutalaiset raamatunselittäjät lukivat Raamattua eri tavoin kuin moderni lukija. Heidän näkemyksensä mukaan se teksti, joka nykyään löytyy heprealaisesta Raamatusta eli kristittyjen Vanhasta testamentista, oli pyhä juuri sellaisessa muodossa, jossa se oli heille välittynyt. Se oli virheetön, ja Jumalalla oli siitä kokonaisnäkemys, joka voisi selvitä myös tulkitsijalle, kun tämä vain tutkisi tekstiä riittävän tarkkaan. Nämä perusoletukset näkyvät tavassa, jolla antiikin eksegeetit lukivat ja tulkitsivat Raamattuaan. Se voidaan huomata heidän jälkeensä jättämistään teksteistä, alkaen noin 400-luvulta ennen ajanlaskumme alkua ja jatkuen ajanlaskumme ensimmäisiin vuosisatoihin. Antiikin raamatunselittäjät käyttivät yleisesti muun muassa metodia, joka rabbiinisessa kirjallisuudessa tunnetaan nimellä gezera shava. Raamatussa kahdessa tai useammassa kohtaa esiintyviä samoja sanoja ja ilmauksia verrattiin tällöin toisiinsa ja pyrittiin siten saamaan valaistusta epäselvinä pidettyihin tekstinkohtiin. Heprealle, etenkin sen vokalisoimattomassa muodossa, on tyypillistä homonyymisyys. Samannäköiset sanat voivat eri yhteyksissä tarkoittaa eri asioita. Varhaiset eksegeetit päätyivät usein tästä ilmiöstä nouseviin, keskenään vaihtoehtoisiin tulkintoihin. Toisaalta he saattoivat myös tarvittaessa selittää tekstinkohtaa toisella tekstinkohdalla ainoastaan näiden sisällöllisenkin yhtäläisyyden perusteella. Tässä väitöstutkimuksessa tarkastellaan näitä varhaisia, meille nimettömiksi jääneitä raamatunselittäjiä ja heidän tulkintojaan käyttämällä tutkimuksen lähtökohtana Malakian kirjaa. Malakiaa, joka on peräisin noin vuodelta 475 ennen ajanlaskumme alkua, voidaan pitää yhtenä tärkeimmistä ja varhaisimmista teksteistä, joissa traditioita yhdistellään ja kerrotaan uudelleen edellä mainittuihin perusajatuksiin nojaten ja niihin pohjautuvia menetelmiä käyttäen. Toisaalta Malakian kirjaa on myös tulkittu samojen periaatteiden mukaisesti jo sen myöhemmältä ajalta peräisin olevissa loppujakeissa, ja sittemmin muussa varhaisessa juutalaisessa kirjallisuudessa sekä Uudessa testamentissa. Väitöstutkimuksessa tarkastellaan erityisesti niitä viittä henkilöä, jotka mainitaan Malakian kirjassa: Jaakobia, Esauta, Leeviä, Moosesta ja Eliaa. Kirjoittaja tutkii, miten heidän hahmojaan on käytetty Malakian kirjassa, millaisiin heitä koskeviin traditioihin tämä käyttötapa perustuu, ja missä määrin Malakian kirjan vaikutus on havaittavissa myöhemmässä näihin henkilöihin liitetyssä perinteessä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect hemagglutination test for a seroepidemiological survey of Streptococcus pyogenes infection was standardized. This is an improved modification of the indirect hemagglutination test which utilizes an unstable reagent prepared with fresh blood cells. Two types of bacterial antigens represented by extracellular products and purified streptolysin O were assayed, but only the former antigen gave good results. Pretreatment of the bacterial antigen with 0.15 M NaOH and neutralization to pH 5.5, as well as postfixation of sensitized red cells with 0.1% glutaraldehyde at 56oC for 30 min were found to be essential to give long stability to the reagent in liquid suspension, at least 9 months at 4oC. A total of 564 serum samples with high, moderate and low anti-streptolysin O antibodies as determined by the neutralization assay were studied by the indirect hemagglutination test using the new reagent. The sensitivity, specificity, efficiency, positive predictive value and negative predictive value of the test in relation to the neutralization assay were 0.950, 0.975, 0.963, 0.973, and 0.955, respectively. The kappa agreement index between the two techniques was high (0.926) and ranked as "almost perfect". Antibody levels detected by both techniques also presented a high positive correlation (rs = 0.726). Five reagent batches successively produced proved to be reproducible. Thus, the improved indirect hemagglutination test seems to be useful for public health laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluated the correlation between the behavior of mice in the forced swimming test (FST) and in the elevated plus-maze (PM). The effect of the order of the experiments, i.e., the influence of the first test (FST or PM) on mouse behavior in the second test (PM or FST, respectively) was compared to handled animals (HAND). The execution of FST one week before the plus-maze (FST-PM, N = 10), in comparison to mice that were only handled (HAND-PM, N = 10) in week 1, decreased % open entries (HAND-PM: 33.6 ± 2.9; FST-PM: 20.0 ± 3.9; mean ± SEM; P<0.02) and % open time (HAND-PM: 18.9 ± 3.3; FST-PM: 9.0 ± 1.9; P<0.03), suggesting an anxiogenic effect. No significant effect was seen in the number of closed arm entries (FST-PM: 9.5 (7.0-11.0); HAND-PM: 10.0 (4.0-14.5), median (interquartile range); U = 46.5; P>0.10). A prior test in the plus-maze (PM-FST) did not change % immobility time in the FST when compared to the HAND-FST group (HAND-FST: 57.7 ± 3.9; PM-FST: 65.7 ± 3.2; mean ± SEM; P>0.10). Since these data suggest that there is an order effect, the correlation was evaluated separately with each test sequence: FST-PM (N = 20) and PM-FST (N = 18). There was no significant correlation between % immobility time in the FST and plus-maze indexes (% time and entries in open arms) in any test sequence (r: -0.07 to 0.18). These data suggest that mouse behavior in the elevated plus-maze is not related to behavior in the forced swimming test and that a forced swimming test before the plus-maze has an anxiogenic effect even after a one-week interval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measure "mu", proposed as an index of the ability to coordinate concurrent box-crossing (BC) and digit-span (DS) tasks in the dual task (DT), should reflect the capacity of the executive component of the working memory system. We investigated the effect of practice in BC and of a change in the digit span on mu by adding previous practice trials in BC and diminishing, maintaining or increasing the digit sequence length. The mu behavior was evaluated throughout three trials of the test. Reported strategies in digit tasks were also analyzed. Subjects with diminished span showed the best performance in DT due to a stable performance in DS and BC in the single- and dual-task conditions. These subjects also showed a more stable performance throughout trials. Subjects with diminished span tended to employ effortless strategies, whereas subjects with increased span employed effort-requiring strategies and showed the lowest means of mu. Subjects with initial practice trials showed the best performance in BC and the most differentiated performance between the single- and dual-task conditions in BC. The correlation coefficient between the mu values obtained in the first and second trials was 0.814 for subjects with diminished span and practice trials in BC. It seems that the within-session practice in BC and the performance variability in DS affect the reliability of the index mu. To control these factors we propose the introduction of previous practice trials in BC and a modification of the current method to determine the digit sequence length. This proposal should contribute to the development of a more reliable method to evaluate the executive capacity of coordination in the dual-task paradigm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pheochromocytomas are rare chromaffin cell tumors that nevertheless must be excluded in large numbers of patients who develop sustained or episodic hypertension as well as in many others with suggestive symptoms or with a familial history of pheochromocytoma. Diagnosis of pheochromocytoma depends importantly on biochemical evidence of excess catecholamine production by a tumor. Imperfect sensitivity and specificity of commonly available biochemical tests and the low incidence of the tumor among the tested population mean that considerable time and effort can be expended in confirming or ruling out pheochromocytoma in patients where the tumor is suspected. Measurements of plasma free metanephrines provide a superior test compared to other available tests for diagnosis of pheochromocytoma. In particular, the high sensitivity of plasma free metanephrines means that a normal test result reliably excludes all but the smallest of pheochromocytomas so that no other tests are necessary. Measurements of plasma free metanephrines, when systematically combined with other diagnostic procedures outlined in this review, provide a more efficient, reliable and cost-effective approach for diagnosis of pheochromocytoma than offered by previously available approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental drugs and/or plant extracts are often dissolved in solvents, including propylene glycol. Nevertheless, there is evidence for psychoactive properties of this alcohol. In this study we found that in the hole-board test 10% propylene glycol did not modify the head-dipping behavior. However, 30% propylene glycol induced an increase in the number of head-dips (46.92 ± 2.37 compared to 33.83 ± 4.39, P<0.05, ANOVA/Student-Newman-Keuls), an effect comparable to that obtained with 0.5 mg/kg diazepam (from 33.83 ± 4.39 to 54 ± 3.8, P<0.01, ANOVA/Student-Newman-Keuls). These results demonstrate that 30% propylene glycol has significant anxiolytic effects in this model and therefore cannot be used as an innocuous solvent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Undernutrition of dams and pups disrupts the retrieval efficiency of mothers. However, if the mothers are assessed in their home cages, they spend more time with their litters. In the present study the effect of test conditions on pup retrieval behavior of mothers receiving a 25% (well-nourished group) and 8% casein diet (undernourished group) was examined. In agreement with previous studies, undernourished mothers spent more time with their litters than well-nourished dams as lactation proceeded. Pup retrieval behavior varied with test conditions. In the first experiment, the maternal behavior of dams was assessed by the standard procedure (pups were separated from their mother and scattered over the floor of the home cage). The mother was then returned and the number of retrieved pups was recorded. From day 3 to 8, the retrieval efficiency of undernourished dams decreased, while the retrieval efficiency of well-nourished mothers did not vary. In the second experiment, mothers were subjected to a single retrieval test (on day 9 of lactation) using the procedure described for experiment 1. No difference between well-nourished and undernourished mothers was observed. In the third experiment, seven-day-old pups were separated from the mothers and returned individually to a clean home cage. Dietary treatment did not affect the retrieval efficiency. However, undernourished dams reconstructed the nest more slowly than did well-nourished dams. Taken together, these results suggest that pup retrieval behavior of the undernourished mother is not impaired by dietary restriction when the maternal environment is disturbed minimally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to verify the sensitivity to the carbon dioxide (CO2) challenge test of panic disorder (PD) patients with respiratory and nonrespiratory subtypes of the disorder. Our hypothesis is that the respiratory subtype is more sensitive to 35% CO2. Twenty-seven PD subjects with or without agoraphobia were classified into respiratory and nonrespiratory subtypes on the basis of the presence of respiratory symptoms during their panic attacks. The tests were carried out in a double-blind manner using two mixtures: 1) 35% CO2 and 65% O2, and 2) 100% atmospheric compressed air, 20 min apart. The tests were repeated after 2 weeks during which the participants in the study did not receive any psychotropic drugs. At least 15 of 16 (93.7%) respiratory PD subtype patients and 5 of 11 (43.4%) nonrespiratory PD patients had a panic attack during one of two CO2 challenges (P = 0.009, Fisher exact test). Respiratory PD subtype patients were more sensitive to the CO2 challenge test. There was agreement between the severity of PD measured by the Clinical Global Impression (CGI) Scale and the subtype of PD. Higher CGI scores in the respiratory PD subtype could reflect a greater sensitivity to the CO2 challenge due to a greater severity of PD. Carbon dioxide challenges in PD may define PD subtypes and their underlying mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Norms for the Gardner Steadiness Test and the Purdue Pegboard were developed for the neuropsychological assessment of children in the metropolitan area of Rio de Janeiro. A computer-generated unbiased sample of 346 children with a mean age of 9.4 years (SD = 2.76), who were attending a large normal public school in this urban area, was the subject of this study. Two boys were removed from the study, one for refusing to participate and the other due to severe strabismus. Therefore, the final sample contained 344 children (173 boys and 171 girls). Sex and age of the child and hand preferred for writing, but not ethnic membership or social class, had significant effects on performance in the Gardner Steadiness Test and the Purdue Pegboard. Girls outperformed boys. Older children performed better than younger children. However, the predictive relationship between age of the child and neuropsychological performance included linear and curvilinear components. Comparison of the present results to data gathered in the United States revealed that the performance of this group of Brazilian children is equivalent to that of US children after Bonferroni's correction of the alpha level of significance. It is concluded that sex and age of the child and hand preferred for writing should be taken into account when using the normative data for the two instruments evaluated in the present study. Furthermore, the relevance of neurobehavioral antidotes for the obliteration of some of the probable neuropsychological effects of cultural deprivation in Brazilian public school children is hypothesized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The break point of the curve of blood lactate vs exercise load has been called anaerobic threshold (AT) and is considered to be an important indicator of endurance exercise capacity in human subjects. There are few studies of AT determination in animals. We describe a protocol for AT determination by the "lactate minimum test" in rats during swimming exercise. The test is based on the premise that during an incremental exercise test, and after a bout of maximal exercise, blood lactate decreases to a minimum and then increases again. This minimum value indicates the intensity of the AT. Adult male (90 days) Wistar rats adapted to swimming for 2 weeks were used. The initial state of lactic acidosis was obtained by making the animals jump into the water and swim while carrying a load equivalent to 50% of body weight for 6 min (30-s exercise interrupted by a 30-s rest). After a 9-min rest, blood was collected and the incremental swimming test was started. The test consisted of swimming while supporting loads of 4.5, 5.0, 5.5, 6.0 and 7.0% of body weight. Each exercise load lasted 5 min and was followed by a 30-s rest during which blood samples were taken. The blood lactate minimum was determined from a zero-gradient tangent to a spline function fitting the blood lactate vs workload curve. AT was estimated to be 4.95 ± 0.10% of body weight while interpolated blood lactate was 7.17 ± 0.16 mmol/l. These results suggest the application of AT determination in animal studies concerning metabolism during exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phonological loop is a component of the working memory system specifically involved in the processing and manipulation of limited amounts of information of a sound-based phonological nature. Phonological memory can be assessed by the Children's Test of Nonword Repetition (CNRep) in English speakers but not in Portuguese speakers due to phonotactic differences between the two languages. The objectives of the present study were: 1) to develop the Brazilian Children's Test of Pseudoword Repetition (BCPR), a Portuguese version of the CNRep, and 2) to validate the BCPR by correlation with the Auditory Digit Span Test from the Stanford-Binet Intelligence Scale. The BCPR and Digit Span were assessed in 182 children aged 4-10 years, 84 from Minas Gerais State (42 from a rural region) and 98 from the city of São Paulo. There are subject age and word length effects causing repetition accuracy to decline as a function of the number of syllables of the pseudowords. Correlations between BCPR and Digit Span forward (r = 0.50; P <= 0.01) and backward (r = 0.43; P <= 0.01) were found, and partial correlation indicated that higher BCPR scores were associated with higher Digit Span scores. BCPR appears to depend more on schooling, while Digit Span was more related to development. The results demonstrate that the BCPR is a reliable measure of phonological working memory, similar to the CNRep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 µg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 µg/paw) and dipyrone (80-320 µg/paw) on carrageenin- (200 µg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 µg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.