939 resultados para Short-circuit faults diagnostic
Resumo:
The effects of electron temperature on the radiation fields and the resistance of a short dipole antenna embedded in a uniaxial plasma have been studied. It is found that for ω < ω_p the antenna excites two waves, a slow wave and a fast wave. These waves propagate only within a cone whose axis is parallel to the biasing magnetostatic field B_o and whose semicone angle is slightly less than sin ^(-1) (ω/ω_p). In the case of ω > ω_p the antenna excites two separate modes of radiation. One of the modes is the electromagnetic mode, while the other mode is of hot plasma origin. A characteristic interference structure is noted in the angular distribution of the field. The far fields are evaluated by asymptotic methods, while the near fields are calculated numerically. The effects of antenna length ℓ, electron thermal speed, collisional and Landau damping on the near field patterns have been studied.
The input and the radiation resistances are calculated and are shown to remain finite for nonzero electron thermal velocities. The effect of Landau damping and the antenna length on the input and radiation resistances has been considered.
The radiation condition for solving Maxwell's equations is discussed and the phase and group velocities for propagation given. It is found that for ω < ω_p in the radial direction (cylindrical coordinates) the power flow is in the opposite direction to that of the phase propagation. For ω > ω_p the hot plasma mode has similar characteristics.
Resumo:
During the 1950s and 1960s, F.J.H. Mackereth developed and published plans for a series of pneumatic samplers for lake sediments. Unfortunately, as the equipment was continually evolving during ensuing research, no user manuals, beyond the original publication, had been produced. Over the last few years there have been a few potentially very serious accidents with the 1-metre corer, which has prompted the authors to carry out a risk assessment. This highlighted two weaknesses in the design and its later developments. They can be corrected simply by checking for screw threads that may have been added to the exhaust port on the mini-corer, and by changing the operating procedure. An A4 nine-page user manual is now available from the authors. A small charge ( pound sterling 10 in 1998) will be made to cover handling costs and postage.
Resumo:
The Danube is ca. 2850 km in length and is the second largest river in Europe. The Austrian part of the Danube falls 156 metres in altitude over its 351 km length and, since the early 1950s, the river has been developed into a power-generating waterway, so that the continuity of the river is now interrupted by ten impounded areas. Only two stretches of the original free-flowing river are left, the Wachau region (above river-km 2005, west of Vienna) and the region downstream from the impoundment at Vienna (river-km 1921). Most of the recent theories and concepts related to invertebrates, in the context of the ecology of running waters, are based on studies on small streams, whereas investigations of large rivers have played a minor role for a long time, mainly due to methodological difficulties. The authors' recent detailed studies on macroinvertebrates in the free-flowing section of the Danube below Vienna, provide an excellent opportunity to survey or restate scientific hypotheses on the basis of a large river. In this review the main interest focuses on the investigation of biodiversity, i.e. the number of species and their relative proportions in the whole invertebrate community, as well as major governing environmental factors. The article summarises the species composition, the important environmental variables at the river cross-section and the effect of upstream impoundment on the riverbed and its fauna.
Resumo:
OKACOM's Transboundary Diagnostic Analysis study used integrated flows analysis to develop scenarios for possible developments in the Okavango River Basin. (PDF contains 2 pages)
Resumo:
We introduce an in vitro diagnostic magnetic biosensing platform for immunoassay and nucleic acid detection. The platform has key characteristics for a point-of-use (POU) diagnostic: portability, low-power consumption, low cost, and multiplexing capability. As a demonstration of capabilities, we use this platform for the room temperature, amplification-free detection of a 31 bp DNA oligomer and interferon-gamma (a protein relevant for tuberculosis diagnosis). Reliable assay measurements down to 100 pM for the DNA and 1 pM for the protein are demonstrated. We introduce a novel "magnetic freezing" technique for baseline measurement elimination and to enable spatial multiplexing. We have created a general protocol for adapting integrated circuit (IC) sensors to any of hundreds of commercially available immunoassay kits and custom designed DNA sequences.
We also introduce a method for immunotherapy treatment of malignant gliomas. We utilize leukocytes internalized with immunostimulatory nanoparticle-oligonucleotide conjugates to localize and retain immune cells near the tumor site. As a proof-of-principle, we develop a novel cell imaging and incubation chamber for in vitro magnetic motility experiments. We use the apparatus to demonstrate the controlled movement of magnetically loaded THP-1 leukocytes.
Finally, we introduce an IC transmitter and power ampli er (PA) that utilizes electronic digital infrastructure, sensors, and actuators to self-heal and adapt to process, dynamic, and environmental variation. Traditional IC design has achieved incredible degrees of reliability by ensuring that billions of transistors on a single IC die are all simultaneously functional. Reliability becomes increasingly difficult as the size of a transistor shrinks. Self-healing can mitigate these variations.
Resumo:
During the past few years the attention of architects, engineers and others encased in or connected with the building industry has been attracted to the possibilities of the application of welding processes to the joining of structural members. As oxy-acetylene welding was developed before electric arc welding became perfected it was only natural that the gas torch should be first considered. It developed however on examination of the two processes that while acetylene welding gave better results in most cases it was only in the hands of experts that it could consistently outscore the arc as a welding medium. Arc-welding has the advantage over the acetylene process, where each individual operator must use his own judgement as to the proper flame, in that a squad of arc-welders can work under the direction of a single expert supervisor who accepts the responsibility of fixing the current value and of determining the proper size of welding rod to be used on any given type of work.
Resumo:
The re-ignition characteristics (variation of re-ignition voltage with time after current zero) of short alternating current arcs between plane brass electrodes in air were studied by observing the average re-ignition voltages on the screen of a cathode-ray oscilloscope and controlling the rates of rise of voltage by varying the shunting capacitance and hence the natural period of oscillation of the reactors used to limit the current. The shape of these characteristics and the effects on them of varying the electrode separation, air pressure, and current strength were determined.
The results show that short arc spaces recover dielectric strength in two distinct stages. The first stage agrees in shape and magnitude with a previously developed theory that all voltage is concentrated across a partially deionized space charge layer which increases its breakdown voltage with diminishing density of ionization in the field-tree space. The second stage appears to follow complete deionization by the electric field due to displacement of the field-free region by the space charge layer, its magnitude and shape appearing to be due simply to increase in gas density due to cooling. Temperatures calculated from this second stage and ion densities determined from the first stage by means of the space charge equation and an extrapolation of the temperature curve are consistent with recent measurements of arc value by other methods. Analysis or the decrease with time of the apparent ion density shows that diffusion alone is adequate to explain the results and that volume recombination is not. The effects on the characteristics of variations in the parameters investigated are found to be in accord with previous results and with the theory if deionization mainly by diffusion be assumed.
Resumo:
In this thesis, I develop the velocity and structure models for the Los Angeles Basin and Southern Peru. The ultimate goal is to better understand the geological processes involved in the basin and subduction zone dynamics. The results are obtained from seismic interferometry using ambient noise and receiver functions using earthquake- generated waves. Some unusual signals specific to the local structures are also studied. The main findings are summarized as follows:
(1) Los Angeles Basin
The shear wave velocities range from 0.5 to 3.0 km/s in the sediments, with lateral gradients at the Newport-Inglewood, Compton-Los Alamitos, and Whittier Faults. The basin is a maximum of 8 km deep along the profile, and the Moho rises to a depth of 17 km under the basin. The basin has a stretch factor of 2.6 in the center decreasing to 1.3 at the edges, and is in approximate isostatic equilibrium. This "high-density" (~1 km spacing) "short-duration" (~1.5 month) experiment may serve as a prototype experiment that will allow basins to be covered by this type of low-cost survey.
(2) Peruvian subduction zone
Two prominent mid-crust structures are revealed in the 70 km thick crust under the Central Andes: a low-velocity zone interpreted as partially molten rocks beneath the Western Cordillera – Altiplano Plateau, and the underthrusting Brazilian Shield beneath the Eastern Cordillera. The low-velocity zone is oblique to the present trench, and possibly indicates the location of the volcanic arcs formed during the steepening of the Oligocene flat slab beneath the Altiplano Plateau.
The Nazca slab changes from normal dipping (~25 degrees) subduction in the southeast to flat subduction in the northwest of the study area. In the flat subduction regime, the slab subducts to ~100 km depth and then remains flat for ~300 km distance before it resumes a normal dipping geometry. The flat part closely follows the topography of the continental Moho above, indicating a strong suction force between the slab and the overriding plate. A high-velocity mantle wedge exists above the western half of the flat slab, which indicates the lack of melting and thus explains the cessation of the volcanism above. The velocity turns to normal values before the slab steepens again, indicating possible resumption of dehydration and ecologitization.
(3) Some unusual signals
Strong higher-mode Rayleigh waves due to the basin structure are observed in the periods less than 5 s. The particle motions provide a good test for distinguishing between the fundamental and higher mode. The precursor and coda waves relative to the interstation Rayleigh waves are observed, and modeled with a strong scatterer located in the active volcanic area in Southern Peru. In contrast with the usual receiver function analysis, multiples are extensively involved in this thesis. In the LA Basin, a good image is only from PpPs multiples, while in Peru, PpPp multiples contribute significantly to the final results.
Resumo:
In the sinusoidal phase modulating interferometer technique, the high-speed CCD is necessary to detect the interference signals. The reason of ordinary CCD's low frame rate was analyzed, and a novel high-speed image sensing technique with adjustable frame rate based on ail ordinary CCD was proposed. And the principle of the image sensor was analyzed. When the maximum frequency and channel bandwidth were constant, a custom high-speed sensor was designed by using the ordinary CCD under the control of the special driving circuit. The frame rate of the ordinary CCD has been enhanced by controlling the number of pixels of every frame; therefore, the ordinary of CCD can be used as the high frame rate image sensor with small amount of pixels. The multi-output high-speed image sensor has the deficiencies of low accuracy, and high cost, while the high-speed image senor with small number of pixels by using this technique can overcome theses faults. The light intensity varying with time was measured by using the image sensor. The frame rate was LIP to 1600 frame per second (f/s), and the size of every frame and the frame rate were adjustable. The correlation coefficient between the measurement result and the standard values were higher than 0.98026, and the relative error was lower than 0.53%. The experimental results show that this sensor is fit to the measurements of sinusoidal phase modulating interferometer technique. (c) 2007 Elsevier GmbH. All rights reserved.