988 resultados para SINUS FLOOR
Resumo:
INTRODUCTION: Vagal activity is thought to influence atrial electrophysiological properties and play a role in the initiation and maintenance of atrial fibrillation (AF). In this study, we assessed the effects of acute vagal stimulation (vagus_stim) on atrial conduction times, atrial and pulmonary vein (PV) refractoriness, and vulnerability to induction of AF in the rabbit heart with intact autonomic innervation. METHODS: An open-chest epicardial approach was performed in 11 rabbits (New Zealand; 3.9-5.0 kg), anesthetized and artificially ventilated after neuromuscular blockade. A 3-lead ECG was obtained. Atrial electrograms were recorded along the atria, from right to left (four monopolar electrodes), together with a circular electrode adapted for proximal left PV assessment. Acute vagus nerve stimulation was obtained with bipolar electrodes (20 Hz). Epicardial activation was recorded in sinus rhythm, and the conduction time from right (RA) to left atrium (LA), and from RA to PVs, was measured in basal conditions and during vagus_stim. The atrial effective refractory period (ERP) and dispersion of refractoriness (Disp_A) were analyzed. Vulnerability to AF induction was assessed at the right (RAA) and left (LAA) atrial appendages and the PVs. Atrial stimulation (50 Hz) was performed alone or combined with vagus_stim. Heart rate and blood pressure were monitored. RESULTS: In basal conditions, there was a significant delay in conduction from RA to PVs, not influenced by vagus_stim, and the PV ERPs were shorter than those measured in LA and LAA, but without significant differences compared to RA and RAA. During vagus_stim, conduction times between RA and LA increased from 16+8 ms to 27+6 ms (p < 0.05) and ERPs shortened significantly in RA, LAA and LA (p < 0.05), but not in RAA. There were no significant differences in Disp_A. AF induction was reproducible in 45% of cases at 50 Hz and in 100% at 50 Hz+vagus_stim (p < 0.05). The duration of inducible AF increased from 1.0 +/- 0.2 s to 12.0 +/- 4.5 s with 50 Hz+vagus_stim (p < 0.01). AF lasted >10 s in 45.4% of rabbits during vagus_stim, and ceased after vagus_stim in 4 out of these 5 cases. In 3 animals, PV tachycardia, with fibrillatory conduction, induced with 50 Hz PV pacing during vagus_stim. CONCLUSIONS: Vagus_stim reduces interatrial conduction velocity and significantly shortens atrial ERP, contributing to the induction and duration of AF episodes in the in vivo rabbit heart. This model may be useful for the assessment of autonomic influence on the pathophysiology of AF.
Resumo:
The autonomic nervous system (ANS) plays a role as a modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). The clinical pattern of vagally mediated PAF has been observed mainly in young patients. Neurocardiogenic responses during orthostatic stress are related to autonomic reflexes in which the vagal influence predominates. AIM: To evaluate the susceptibility of elderly patients with PAF to activation of vasovagal syncope mechanisms. METHODS: We performed passive head-up tilt testing (HUT) in 34 patients (62% women, aged 72 +/- 7 years), with > or = 1 year of clinical history of PAF--19 without structural heart disease, 11 with hypertensive heart disease and 4 with coronary artery disease (who had no previous myocardial infarction, had undergone myocardial revascularization, and had no documented ischemia) (PAF group), and compared the results with those obtained in a group of 34 age-matched patients (53% women, aged 74 +/- 6 years), who underwent HUT due to recurrent syncope (Sc group). In this group, 21 had no documented heart disease and none had a clinical history of AF. There was no diabetes, congestive heart failure or syncope in the PAF group. After a supine resting period, the subjects were tilted at 70 degrees for 20 minutes while in sinus rhythm. No provocative agents were used to complement the HUT. ECG and blood pressure were continuously monitored (Task Force Monitor, CNSystems). The test was considered positive when syncope or presyncope occurred with bradycardia and/or arterial hypotension. Abnormal responses were classified as cardioinhibitory, vasodepressor or mixed. RESULTS: HUT was positive in seven patients of the PAF group--vasodepressor response in five and mixed in two (20.5% of the total; 26.3% of those without heart disease)--and in eight patients (vasodepressor in six and mixed in two) of the Sc group (p=NS). During HUT, three patients of the PAF group had short periods of self-limited PAF (in one, after vasodepressor syncope). There were no differences in gender distribution, age or heart disease. No cardioinhibitory responses or orthostatic hypotension were observed. CONCLUSION: In elderly patients with PAF, a significant number of false positive results during passive HUT may be expected, suggesting increased vasovagal reactions despite aging. This suggests that ANS imbalances may be observed in this population.
Resumo:
The autonomic nervous system (ANS) is known to be an important modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). Changes in ANS control of heart rate variability (HRV) occur during orthostatism to maintain cardiovascular homeostasis. Wavelet transform has emerged as a useful tool that provides time-frequency decomposition of the signal under investigation, enabling intermittent components of transient phenomena to be analyzed. AIM: To study HRV during head-up tilt (HUT) with wavelet transform analysis in PAF patients and healthy individuals (normals). METHODS: Twenty-one patients with PAF (8 men; age 58 +/- 14 yrs) were examined and compared with 21 normals (7 men, age 48 +/- 12 yrs). After a supine resting period, all subjects underwent passive HUT (60 degrees) while in sinus rhythm. Continuous monitoring of ECG and blood pressure was carried out (Task Force Monitor, CNSystems). Acute changes in RR-intervals were assessed by wavelet analysis and low-frequency power (LF: 0.04-0.15 Hz), high-frequency power (HF: 0.15-0.60 Hz) and LF/HF (sympathovagal) were calculated for 1) the last 2 min of the supine period; 2) the 15 sec of tilting movement (TM); and 3) the 1st (TT1) and 2nd (TT2) min of HUT. Data are expressed as means +/- SEM. RESULTS: Baseline and HUT RR-intervals were similar for the two groups. Supine basal blood pressure was also similar for the two groups, with a sustained increase in PAF patients, and a decrease followed by an increase and then recovery in normals. Basal LF, HF and LF/ HF values in PAF patients were 632 +/- 162 ms2, 534 +/- 231 ms2 and 1.95 +/- 0.39 respectively, and 1058 +/- 223 ms2, 789 +/- 244 ms2 and 2.4 +/- 0.36 respectively in normals (p = NS). During TM, LF, HF and LF/HF values for PAF patients were 747 +/- 277 ms2, 387 +/- 94 ms2 and 2.9 +/- 0.6 respectively, and 1316 +/- 315 ms2, 698 +/- 148 ms2 and 2.8 +/- 0.6 respectively in normals (p < 0.05 for LF and HF). During TF1, LF, HF and LF/ HF values for PAF patients were 1243 +/- 432 ms2, 302 +/- 88 ms2 and 7.7 +/- 2.4 respectively, and 1992 +/- 398 ms2, 333 +/- 76 ms2 and 7.8 +/- 0.98 respectively for normals (p < 0.05 for LF). During TF2, LF, HF and LF/HF values for PAF patients were 871 +/- 256 ms2, 242 +/- 51 ms2 and 4.7 +/- 0.9 respectively, and 1263 +/- 335 ms2, 317 +/- 108 ms2 and 8.6 +/- 0.68 respectively for normals (p < 0.05 for LF/HF). The dynamic profile of HRV showed that LF and HF values in PAF patients did not change significantly during TM or TT2, and LF/HF did not change during TM but increased in TT1 and TT2. CONCLUSION: Patients with PAF present alterations in HRV during orthostatism, with decreased LF and HF power during TM, without significant variations during the first minutes of HUT. These findings suggest that wavelet transform analysis may provide new insights when assessing autonomic heart regulation and highlight the presence of ANS disturbances in PAF.
Resumo:
Atrial electrical remodeling plays a part in recurrence of atrial fibrillation (AF). It has been related to an increase in heterogeneity of atrial refractoriness that facilitates the occurrence of multiple reentry wavelets and vulnerability to AF. AIM: To examine the relationship between dispersion of atrial refractoriness (Disp_A) and vulnerability to AF induction (A_Vuln) in patients with clinical paroxysmal AF (PAF). METHODS: Thirty-six patients (22 male; age 55+/-13 years) with > or =1 year of history of PAF (no underlying structural heart disease--n=20, systemic hypertension--n=14, mitral valve prolapse--n=1, surgically corrected pulmonary stenosis--n=1), underwent electrophysiological study (EPS) while off medication. The atrial effective refractory period (AERP) was assessed at five different sites--high (HRA) and low (LRA) lateral right atrium, high interatrial septum (IAS), proximal (pCS) and distal (dCS) coronary sinus--during a cycle length of 600 ms. AERP was taken as the longest S1-S2 interval that failed to initiate a propagation response. Disp_A was calculated as the difference between the longest and shortest AERP. A_Vuln was defined as the ability to induce AF with 1-2 extrastimuli or with incremental atrial pacing (600-300 ms) from the HRA or dCS. The EPS included analysis of focal electrical activity based on the presence of supraventricular ectopic beats (spontaneous or with provocative maneuvers). The patients were divided into group A--AF inducible (n=25) and group B--AF not inducible (n=11). Disp_A was analyzed to determine any association with A_Vuln. Disp_A and A_Vuln were also examined in those patients with documented repetitive focal activity. Logistic regression was used to determine any association of the following variables with A_Vuln: age, systemic hypertension, left ventricular hypertrophy, left atrial size, left ventricular function, duration of PAF, documented atrial flutter/tachycardia and Disp_A. RESULTS: There were no significant differences between the groups with regard to clinical characteristics and echocardiographic data. AF was inducible in 71% of the patients and noninducible in 29%. Group A had greater Disp_A compared to group B (105+/-78 ms vs. 49+/-20 ms; p=0.01). Disp_A was >40 ms in 50% of the patients without A_Vuln and in 91% of those with A_Vuln (p=0.05). Focal activity was demonstrated in 14 cases (39%), 57% of them with A_Vuln. Disp_A was 56+/-23 ms in this group and 92+/-78 ms in the others (p=0.07). Using logistic regression, the only predictor of A_Vuln was Disp_A (p=0.05). CONCLUSION: In patients with paroxysmal AF, Disp_A is a major determinant of A_Vuln. Nevertheless, the degree of nonuniformity of AERP appears to be less important as an electrophysiological substrate for AF due to focal activation.
Resumo:
A criação de infraestruturas passa pela construção de estradas que ligam pontos estratégicos, permitindo acesso a bens e serviços, de forma cómoda e segura. No desenvolvimento deste trabalho é abordado o estudo e projeto de uma variante urbana no concelho de Cinfães, nas especificidades de traçado, pavimentos e sinalização. Inicia-se por uma apresentação sobre o trabalho, os objetivos, estrutura e metodologia utilizada na sua elaboração. São apresentados os softwares utilizados, como editores de imagem (Google Earth, Microsoft ICE e Caesium) que permitem obter e trabalhar imagens panorâmicas, o Civil 3D que possibilita a realização ágil de um projeto de vias, e o Alize-LCPC que determina as caraterísticas de dimensionamento de um pavimento flexível. São apresentados os estudos necessários para a construção da variante em questão passando pela localização da via, o trabalho sobre o levantamento topográfico fornecido pela Câmara Municipal, condicionantes de traçado e serviços afetados. Posteriormente, são abordados alguns conceitos teóricos como geometria do traçado, velocidade, tráfego e visibilidade. Descrevem-se as caraterísticas geométricas de infraestruturas rodoviárias a conhecer anteriormente à realização de um projeto de execução de uma via, como o traçado em planta (alinhamentos retos, curvas, raios, sobreelevação, sobrelargura), perfil longitudinal (trainéis, inclinações, concordâncias verticais) e perfil transversal (faixa de rodagem, bermas, valetas e taludes). É realizada ainda uma apresentação sobre os elementos integrantes de uma plataforma rodoviária e passeio, os seus critérios de dimensionamento, como caraterização do tráfego, temperaturas de serviço e deformações, assim como os elementos teóricos para o estudo de drenagem (período de retorno, precipitação e tipos de dispositivos). São ainda apresentadas as caraterísticas gerais de um projeto de sinalização e segurança, enunciando as marcas rodoviárias e a sinalização vertical. Termina-se apresentando as soluções encontradas e os meios utilizados, para a elaboração do projeto de uma via nova, alargamento de via existente e requalificação de pavimento de um troço de ligação à EN222, expondo ainda as conclusões obtidas na realização do projeto com propostas para desenvolvimento futuros.
Resumo:
"Cor triatriatum dexter" (CTD) is an unusual cyanotic cardiac defect in which the right atrium is subdivided into two distinct chambers due to the persistence of the "sinus venosus" valve. Two patients with CTD ho were evaluated and treatment in 1979 and 1992 are described: the first one, had total anomalous pulmonary venous return to the coronary sinus or "cor triatriatum sinister" as preoperative diagnosis based on M-mode echocardiographic findings. The presence of a membrane inside the right atrium was suspected on cineangiogram. The other one had a preoperative diagnosis of CTD. Anatomic relationships and physiological effects were established by two dimensional and Doppler ultrasonography and confirmed at cardiac catheterization and surgery. High resolution two dimensional echocardiography coupled with Doppler ultrasonography has a definite role in the study of this heart defect.
Resumo:
Slowed atrial conduction may contribute to reentry circuits and vulnerability for atrial fibrillation (AF). The autonomic nervous system (ANS) has modulating effects on electrophysiological properties. However, complex interactions of the ANS with the arrhythmogenic substrate make it difficult to understand the mechanisms underlying induction and maintenance of AF. AIM: To determine the effect of acute ANS modulation in atrial activation times in patients (P) with paroxysmal AF (PAF). METHODS AND RESULTS: 16P (9 men; 59±14years) with PAF, who underwent electrophysiological study before AF ablation, and 15P (7 men; 58±11years) with atrioventricular nodal reentry tachycardia, without documentation or induction of AF (control group). Each group included 7P with arterial hypertension but without underlying structural heart disease. The study was performed while off drugs. Multipolar catheters were placed at the high right atrium (HRA), right atrial appendage (RAA), coronary sinus (CS) and His bundle area (His). At baseline and with HRA pacing (600ms, shortest propagated S2) we measured: i) intra-atrial conduction time (IACT, between RAA and atrial deflection in the distal His), ii) inter-atrial conduction time (interACT, between RAA and distal CS), iii) left atrial activation time (LAAT, between atrial deflection in the distal His and distal CS), iv) bipolar electrogram duration at four atrial sites (RAA, His, proximal and distal CS). In the PAF group, measurements were also determined during handgrip and carotid sinus massage (CSM), and after pharmacological blockade of the ANS (ANSB). AF was induced by HRA programmed stimulation in 56% (self-limited - 6; sustained - 3), 68.8% (self-limited - 6; sustained - 5), and 50% (self-limited - 5; sustained - 3) of the P, in basal, during ANS maneuvers, and after ANSB, respectively (p=NS). IACT, interACT and LAAT significantly lengthened during HRA pacing in both groups (600ms, S2). P with PAF have longer IACT (p<0.05), a higher increase in both IACT, interACT (p<0.01) and electrograms duration (p<0.05) with S2, and more fragmented activity, compared with the control group. Atrial conduction times and electrograms duration were not significantly changed during ANS stimulation. Nevertheless, ANS maneuvers increased heterogeneity of the local electrograms duration. Also, P with sustained AF showed longer interACT and LAAT during CSM. CONCLUSION: Atrial conduction times, electrograms duration and fractionated activity are increased in PAF, suggesting a role for conduction delays in the arrhythmogenic substrate. Acute vagal stimulation is associated with prolonged interACT and LAAT in P with inducible sustained AF and ANS modulation may influence the heterogeneity of atrial electrograms duration.
Resumo:
Empreendimentos industriais requerem o acompanhamento completo e preciso de dados de máquinas em tempo real, integrando as atividades do chão de fábrica com a engenharia, suporte e negócios. É reconhecido que sistemas de monitorização são fundamentais para melhorar a qualidade do produto, reduzir os tempos e para a adaptação rápida às mudanças de produção. Os sensores de processos possuem custos altos, não são compactos e são de difícil implementação. Portanto, seria estratégico desenvolver sistemas de monitorização que usufruem ao máximo dos recursos já existentes nas máquinas e ferramentas e que não representem custos adicionais elevados e de difícil implementação. O uso de PLC nas indústrias é crescente. Estes mostram-se como ferramentas potenciais para atender a estas exigências. Os PLC possuem os recursos necessários para a aquisição de informações e controlo das máquinas, facilitando a interação com um sistema SCADA. O objetivo do presente trabalho é pesquisar soluções sobre sistemas de monitorização que possam substituir um sistema instalado antiquado e encontrar uma solução para o controlo de um processo de vazamento. Para tal, foram consideradas duas soluções: uma passaria por desenvolver um sistema de monitorização que controlasse o processo de vazamento, e outra que permitisse ser o PLC a fazer o controlo, adquirindo um HMI apenas para monitorização. Esta última solução revelou-se como a melhor, visto que um PLC tem mais durabilidade em relação a um PC, em termos de atualizações de hardware e software. Assim, foram criadas funções no PLC para fazer o controlo de vazamento e foi adquirido uma consola Beijer, e respetivo software de programação SCADA, para a criação do sistema de monitorização. Os resultados mostram que o PLC é capaz de executar o controlo, não sendo necessário investir em PC que são mais caros, bastando para isso adquirir sistemas SCADA simples e capazes.
Resumo:
The impact of atrial dispersion of refractoriness (Disp_A) in the inducibility and maintenance of atrial fibrillation (AF) has not been fully resolved. AIM: To study the Disp_A and the vulnerability (A_Vuln) for the induction of self-limited (<60 s) and sustained episodes of AF. METHODS AND RESULTS: Forty-seven patients with paroxysmal AF (PAF): 29 patients without structural heart disease and 18 with hypertensive heart disease. Atrial effective refractory period (ERP) was assessed at five sites--right atrial appendage and low lateral right atrium, high interatrial septum, proximal and distal coronary sinus. We compared three groups: group A - AF not inducible (n=13); group B - AF inducible, self-limited (n=18); group C - AF inducible, sustained (n=16). Age, lone AF, hypertension, left atrial and left ventricular (LV) dimensions, LV systolic function, duration of AF history, atrial flutter/tachycardia, previous antiarrhythmics, and Disp_A were analysed with logistic regression to determine association with A_Vuln for AF inducibility. The ERP at different sites showed no differences among the groups. Group A had a lower Disp_A compared to group B (47+/-20 ms vs 82+/-65 ms; p=0.002), and when compared to group C (47+/-20 ms vs 80+/-55 ms; p=0.008). There was no significant difference in Disp_A between groups B and C. By means of multivariate regression analysis, the only predictor of A_Vuln was Disp_A (p=0.04). Conclusion: In patients with PAF, increased Disp_A represents an electrophysiological marker of A_Vuln. Inducibility of both self-limited and sustained episodes of AF is associated with similar values of Disp_A. These findings suggest that the maintenance of AF is influenced by additional factors.
Resumo:
O disrafismo espinhal oculto inclui todas as situações em que existe um defeito no encerramento do tubo neural ou no seu revestimento, mas cuja lesão resultante é coberta por pele intacta. A apresentação clínica é variável, podendo englobar alterações neurourológicas, malformações ortopédicas ou anomalias cutâneas. A sua incidência global é desconhecida, pois é muitas vezes sub-diagnosticado. Os autores apresentam o caso de um recém-nascido de termo com uma fosseta sagrada e tumefação subcutânea adjacente. A investigação imagiológica revelou lipomielomeningocelo com ancoramento medular e sinus dérmico associado. Como o risco de meningite ascendente não podia ser excluído, a lesão foi removida ao 10º dia de vida com evolução clínica favorável. Pretende-se assim reforçar a importância do exame objectivo rigoroso do recém-nascido e da investigação imagiológica, por ecografia e/ou RMN, de todas as lesões suspeitas da região sacro-coccígea, prevenindo alterações neurológicas graves.
Resumo:
We evaluate the prevalence of intestinal parasites in 504 people and the degree of association between environmental variables and parasites found in population, soil and water in a rural area of Argentina during 2002-2003. A structured survey was used to evaluate the environmental variables and fecal-human, soil and water samples were analyzed. The prevalence of parasites was 45.4%. Most prevalent protozoa were Blastocystis hominis (27.2%) and Giardia lamblia (6.9%), while the most prevalent helminth was Ascaris lumbricoides (3.8%). The analyzed environmental variables showing association (p < 0.05) with presence of parasites in population were: cardboard-tin or wooden house, dirt floor, home or communal water pump, faucet outside the house or public faucet and cesspool or latrine. Parasite forms were found in 82.3% of the soil samples and in 84.2% of the water samples. In both samples we found parasites that were also found in people. In this study we have found deficient sanitary conditions associated with presence of parasites in population and we have evidenced that contaminated soil and water were the source of these parasites.
Resumo:
INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.
Resumo:
The authors analyzed 704 transthoracic echocardiographic (TTE) examinations, performed routinely to all admitted patients to a general 16-bed Intensive Care Unit (ICU) during an 18-month period. Data acquisition and prevalence of abnormalities of cardiac structures and function were assessed, as well as the new, previously unknown severe diagnoses. A TTE was performed within the first 24 h of admission on 704 consecutive patients, with a mean age of 61.5+/-17.5 years, ICU stay of 10.6+/-17.1 days, APACHE II 22.6+/-8.9, and SAPS II 52.7+/-20.4. In four patients, TTE could not be performed. Left ventricular (LV) dimensions were quantified in 689 (97.8%) patients, and LV function in 670 (95.2%) patients. Cardiac output (CO) was determined in 610 (86.7%), and mitral E/A in 399 (85.9% of patients in sinus rhythm). Echocardiographic abnormalities were detected in 234 (33%) patients, the most common being left atrial (LA) enlargement (n=163), and LV dysfunction (n=132). Patients with these alterations were older (66+/-16.5 vs 58.1+/-17.4, p<0.001), presented a higher APACHE II score (24.4+/-8.7 vs 21.1+/-8.9, p<0.001), and had a higher mortality rate (40.1% vs 25.4%, p<0.001). Severe, previously unknown echocardiographic diagnoses were detected in 53 (7.5%) patients; the most frequent condition was severe LV dysfunction. Through a multivariate logistic regression analysis, it was determined that mortality was affected by tricuspid regurgitation (p=0.016, CI 1.007-1.016) and ICU stay (p<0.001, CI 1-1.019). We conclude that TTE can detect most cardiac structures in a general ICU. One-third of the patients studied presented cardiac structural or functional alterations and 7.5% severe previously unknown diagnoses.
Resumo:
BACKGROUND: Schwannomas of the abducens nerve are extremely rare tumors. The tumor may be located within the cavernous sinus or more often at the prepontine region. However, literature research has identified only one case of isolated schwannoma of the orbit, arising from the terminal branches of the abducens nerve to the lateral rectus muscle. This is only the second report of an abducens nerve schwannoma located entirely intraconal. CASE DESCRIPTION: We report a case of an intraorbital abducens nerve schwannoma in a 42-year-old man with no signs of neurofibromatosis. The lesion resulted in progressive diplopia and focal abducens palsy. The clinical, radiologic, and pathologic features are presented. RESULTS: We point the particular aspects and discuss the possible treatments and approaches to preserve nerve function. CONCLUSIONS: Being a benign lesion, one of the goals has always been total removal. The knowledge of the correct anatomic features made us believe that the VI nerve function could be preserved. Our case is the first example of a total removal with eye abduction preserved. Because of that, we believe that it is reasonable to aim for these goals in future cases.
Resumo:
Introduction and hypothesis Puborectalis avulsion is a likely etiological factor for female pelvic organ prolapse(FPOP). We performed a study to establish minimal sonographic criteria for the diagnosis of avulsion. Methods We analysed datasets of 764 women seen at a urogynecological service. Offline analysis of ultrasound datasets was performed blinded to patient data. Tomographic ultrasound imaging (TUI) was used to diagnose avulsion of the puborectalis muscle. Results Logistic regression modelling of TUI data showed that complete avulsion is best diagnosed by requiring the three central tomographic slices to be abnormal. This finding was obtained in 30% of patients and was associated with symptoms and signs of FPOP (P<0.001). Lesser degrees of trauma (‘partial avulsion’) were not associated with symptoms or signs of pelvic floor dysfunction. Conclusions Complete avulsion of the puborectalis muscle is best diagnosed on TUI by requiring all three central slices to be abnormal. Partial trauma seems of limited clinical relevance.