976 resultados para Receiver


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate prospectively the relative accuracy of computed tomographic (CT) angiography, calcium scoring (CS), and both methods combined in demonstrating coronary artery stenoses by using conventional angiography as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board Human Research Ethics Committee, and all patients completed written informed consent. Fifty patients (40 men, 10 women) aged 62 years ± 11 (± standard deviation) who were suspected of having coronary artery disease underwent both conventional coronary angiography and multisection coronary CT angiography with CS. Sensitivity and specificity of CS, CT angiography, and both methods combined in demonstrating luminal stenosis greater than or equal to 50% were determined for each arterial segment, coronary vessel, and patient. Receiver operating characteristic (ROC) curves were generated for CS prediction of significant stenosis, and the Mann-Whitney U test was used for comparison of CS between groups. RESULTS: When used with segment-specific electrocardiographic phase reconstructions, CT angiography demonstrated stenosed segments with 79% sensitivity and 95% specificity. Mean calcium score was greater in segments, vessels, and patients with stenoses than in segments, vessels, and patients without stenoses (P < .001 for all); nine (16%) of 56 stenosed segments, however, had a calcium score of 0. The patient calcium score correlated strongly with the number of stenosed arteries (Spearman {rho} = 0.75, P < .001). CS was more accurate in demonstrating stenosis in patients than in segments (areas under ROC curve were 0.88 and 0.74, respectively). CT angiography, however, was more accurate than CS in demonstrating stenosis in patients, vessels, and segments. The sensitivity and specificity of CS varied according to the threshold used, but when the calcium score cutoff (ie, >150) matched the specificity of CT angiography (95%), the sensitivity of CS in demonstrating stenosed segments was 29% (compared with 79% for CT angiography). Combining CT angiography with CS (at threshold of 400) improved the sensitivity of CT angiography (from 93% to 100%) in demonstrating significant coronary disease in patients, without a loss of specificity (85%); this finding, however, was not statistically significant. CONCLUSION: CT angiography is more accurate than CS in demonstrating coronary stenoses. A patient calcium score of greater than or equal to 400, however, can be used to potentially identify patients with significant coronary stenoses not detected at CT angiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies of the construct of service quality have traditionally been undertaken from the perspective of the service receiver. More recently, research has focused on both the service provider's perspective and the service receiver's perspective. In addition, there have also been some triadic network approaches to the study of service quality. However, there has been very little research into sequential service quality in service-encounter chains (that is, consecutive service performances in a series of service encounters). The incorporation of connected service encounters in services management can improve understanding of sequential service quality in service-encounter chains. This paper provides a customized construct of sequential service quality and  highlights the importance of time, context, and performance threshold in service-encounter chains. Furthermore, the paper presents a customized six-dimensional construct of sequential service quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Theory of Homeostasis posits that Subjective Well-being (SWB) is regulated by a dynamic biological mechanism, assisting to maintain a positive view of life. Further, the theory suggests that clinical depression is the loss of SWB due to the defeat of this homeostatic defence system. To test this hypothesis it was predicted that people who were diagnosed as clinically depressed with the Semi-structured Clinical Interview (SCID-1/NP) based on the DSM-IV-TR Axis 1 would have a Personal Well-being Index-Adult (PWI-A) score below the normative range (70–80% of scale maximum). Following ethical approval a sample of 146 men was obtained and each was assessed on the SCID-1/NP and on the PWI-A. Subjects diagnosed as having one of several pathologies such as post traumatic stress disorder, panic disorder, social phobia and specific phobia were found to score significantly lower on the PWI-A compared to participants who received no diagnosis. However, as the data did not discriminate between currently depressed and persons with other non-depressive psychopathologies, a Receiver Operating Characteristics (ROC) curve analysis was used to explore this data further. Results indicated that the PWI-A was significantly better than guessing in discriminating clinically depressed cases, but only just so. Therefore, while this research found support for the proposition that the loss of SWB indicated clinical depression, the PWI-A is not sufficiently specific for diagnosis, nor can it be concluded that all instances of depression is the failure of SWB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we propose a Geometrically Based Single Bounce Elliptical Model (GBSBEM) for multipath components involving randomly placed scatterers in the scattering region with sensors deployed on a field. The system model assumes a cluster based wireless sensor network (WSN) which collects information from the sensors, filters and modulates the data and transmit it through a wireless channel to be collected at the receiver. We first develop a GBSBE model and based on this model we develop our channel model. Use of Smart antenna system at the receiver end, which exploits various receive diversity combining techniques like Maximal Ratio Combining (MRC), Equal Gain Combining (EGC), and Selection Combining (SC), adds novelty to this system. The performance of these techniques have been proved through matlab simulations and further ahead based on different number of antenna elements present at the receiver array, we calculate the performance of our system in terms of bit-error-rate (BER). Based on the transmission power we quantify for the energy efficiency of our communication model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this article is to review the development and assessment of cardiovascular risk prediction models and to discuss the predictive value of a risk factor as well as to introduce new assessment methods to evaluate a risk prediction model. Many cardiovascular risk prediction models have been developed during the past three decades. However, there has not been consistent agreement regarding how to appropriately assess a risk prediction model, especially when new markers are added to an existing model. The area under the receiver operating characteristic (ROC) curve has traditionally been used to assess the discriminatory ability of a risk prediction model. However, recent studies suggest that this method has its limitations and cannot be the sole approach to evaluate the usefulness of a new marker. New assessment methods are being developed to appropriately assess a risk prediction model and they will be gradually used in clinical and epidemiological studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Assessment of Quality of Life (AQoL) utility instrument was psychometrically developed for the general population. This study aimed to explore its potential as an osteoarthritis (OA) outcome measure.

Methods:
WOMAC, Lequesne index, SF-36, Visual analogue scales and the AQoL were administered to 222 people with OA. The ability of each questionnaire to detect differences between groups was based on (i) self-rated health (SRH) and, (ii) differences between people on an orthopedic waiting list (WL) vs people with OA in the community (C). Comparisons included effect size, relative efficiency and receiver operator characteristic curves.

Results: All instruments detected differences between groups; however no one instrument exhibited superior efficiency. The AQoL demonstrated strong psychometric properties.

Conclusion: The AQoL has equivalent performance to comparator questionnaires commonly used in OA research and would be a useful adjunct to well-established disease specific scales. The AQoL has important advantages; brevity (12 items), facilitates comparisons between disease groups, and delivers a utility score that can be used in health economic evaluations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integrated optical detection is considered to be an important operation in lab-on-a-chips. This paper presents an optical fiber-based micro-sensor that is capable of detecting food substance particles in a lab-on-a-chip. The system consists of a microcontroller and associated circuitry, a laser emitter, a laser receiver, fiber optic cables, a microfluidics chip, and the food substance samples to be tested. When the particles flow through the microfluidic channel in the chip, the receiver’s output voltage varies due to the particles blocking the passage of the laser ray. The changes in the collected signals are analyzed to count the number of particles. Experiments are conducted on several food substance samples including talcum powder, ground ginger, and soy sauce. The experimental results are presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To compare the ability of the metabolic syndrome (MetS), a diabetes prediction model (DPM), a noninvasive risk questionnaire and individual glucose measurements to predict future diabetes.

Design. Five-year longitudinal cohort study. Tools tested included MetS definitions [World Health Organization, International Diabetes Federation, ATPIII and European Group for the study of Insulin Resistance (EGIR)], the FINnish Diabetes RIsk SCore risk questionnaire, the DPM, fasting and 2-h post load plasma glucose.

Setting. Adult Australian population.

Subjects. A total of 5842 men and women without diabetes ≥25 years. Response 58%. A total of 224 incident cases of diabetes.

Results.
In receiver operating characteristic curve analysis, the MetS was not a better predictor of incident diabetes than the DPM or measurement of glucose. The risk for diabetes among those with prediabetes but not MetS was almost triple that of those with MetS but not prediabetes (9.0% vs. 3.4%). Adjusted for component parts, the MetS was not a significant predictor of incident diabetes, except for EGIR in men [OR 2.1 (95% CI 1.2–3.7)].

Conclusions.
A single fasting glucose measurement may be more effective and efficient than published definitions of the MetS or other risk constructs in predicting incident diabetes. Diagnosis of the MetS did not confer increased risk for incident diabetes independent of its individual components, with an exception for EGIR in men. Given these results, debate surrounding the public health utility of a MetS diagnosis, at least for identification of incident diabetes, is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims : To assess the utility of the metabolic syndrome (MetS) and a Diabetes Predicting Model as predictors of incident diabetes.

Methods :
A longitudinal survey was conducted in Mauritius in 1987 (n = 4972; response 80%) and 1992 (n = 3685; follow-up 74.2%). Diabetes status was retrospectively determined using 1999 World Health Organization (WHO) criteria. MetS was determined according to four definitions and sensitivity, positive predictive value (PPV), specificity and the association with incident diabetes before and after adjustment for MetS components calculated.

Results : Of the 3198 at risk, 297 (9.2%) developed diabetes between 1987 and 1992. The WHO MetS definition had the highest prevalence (20.3%), sensitivity (42.1%) and PPV (26.8%) for prediction of incident diabetes, the strongest association with incident diabetes after adjustment for age and sex [odds ratio 4.6 (3.5–6.0)] and was the only definition to show a significant association after adjustment for its component parts (in men only). The low prevalence and sensitivity of the International Diabetes Federation (IDF) and ATPIII MetS definitions resulted from waist circumference cut-points that were high for this population, particularly in men, and both were not superior to a diabetes predicting model on receiver operating characteristic analysis.

Conclusions : Of the MetS definitions tested, the WHO definition best identifies those who go on to develop diabetes, but is not often used in clinical practice. If cut-points or measures of obesity appropriate for this population were used, the IDF and ATPIII MetS definitions could be recommended as useful tools for prediction of diabetes, given their relative simplicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The utility of fatty acids (FAs) as biomarkers of total fat intake is unknown.

Objective: We compared FA changes in red cells (RCs), plasma phospholipids (PLs), and cholesterol esters (CEs) in response to a low-fat diet (LFD) and a moderate-fat diet (MFD) and assessed whether individual or combination of FAs predict LFD.

Design: Postmenopausal women (n = 66) were randomly assigned to receive an LFD (17% of energy from fat) or an MFD (34% of energy from fat) for 6 wk. All foods were provided. FAs in diets and blood were determined by gas-liquid chromatography. FA changes between baseline and end of study were compared across diets by using t tests. FA predictors of an LFD were selected by logistic regression.

Results: Many FAs in RCs, PLs, and CEs responded differently to the 2 diets. Changes from baseline with an LFD for palmitic acid (16:0) (3–11% increase), behenic (22:0) and lignoceric (24:0) acids (3–20% decrease, in RCs and PLs only), cis-monounsaturated FA (MUFA) (25–35% increase), linoleic acid (18:2n–6) (11–13% decrease), trans octadecanoic acids (trans 18:1) (7–20% decrease), and n–6 highly unsaturated FA (HUFA) (2–8% increase) were significantly different from changes with an MFD. Individually, 18:2n–6 and trans 18:1 were strong predictors of an LFD [receiver operating characteristic (ROC) curves: 0.92–0.80). A logistic regression model with trans 18:1, 18:2n–6, and vaccenic acid (18:1n–7) predicted an LFD with high specificity and sensitivity (ROC curves: 0.99).

Conclusions: Saturated FA, cisMUFA, n–6 HUFA, and exogenous FAs greatly differed in their response to the LFD and MFD. Parallel responses were observed in RCs, PLs, and CEs. A model with a combination of FAs almost perfectly differentiated the consumption of 34% fat from that of 17% fat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many risk prediction models have been developed for cardiovascular diseases in different countries during the past three decades. However, there has not been consistent agreement regarding how to appropriately assess a risk prediction model, especially when new markers are added to an established risk prediction model. Researchers often use the area under the receiver operating characteristic curve (ROC) to assess the discriminatory ability of a risk prediction model. However, recent studies suggest that this method has serious limitations and cannot be the sole approach to evaluate the usefulness of a new marker in clinical and epidemiological studies. To overcome the shortcomings of this traditional method, new assessment methods have been proposed. The aim of this article is to overview various risk prediction models for cardiovascular diseases, to describe the receiver operating characteristic curve method and discuss some new assessment methods proposed recently. Some of the methods were illustrated with figures from a cardiovascular disease study in Australia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Animal color pattern phenotypes evolve rapidly. What influences their evolution? Because color patterns are used in communication, selection for signal efficacy, relative to the intended receiver's visual system, may explain and predict the direction of evolution. We investigated this in bowerbirds, whose color patterns consist of plumage, bower structure, and ornaments and whose visual displays are presented under predictable visual conditions. We used data on avian vision, environmental conditions, color pattern properties, and an estimate of the bowerbird phylogeny to test hypotheses about evolutionary effects of visual processing. Different components of the color pattern evolve differently. Plumage sexual dimorphism increased and then decreased, while overall (plumage plus bower) visual contrast increased. The use of bowers allows relative crypsis of the bird but increased efficacy of the signal as a whole. Ornaments do not elaborate existing plumage features but instead are innovations (new color schemes) that increase signal efficacy. Isolation between species could be facilitated by plumage but not ornaments, because we observed character displacement only in plumage. Bowerbird color pattern evolution is at least partially predictable from the function of the visual system and from knowledge of different functions of different components of the color patterns. This provides clues to how more constrained visual signaling systems may evolve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently, diagnostic tests for mesenteric ischaemia and infarction are inadequate due to poor sensitivity and specificity. In addition, many potential markers appear too late to be clinically useful. At present, definitive diagnosis can only be made at the time of surgery, which is not ideal as surgery is often to be avoided in critically ill and elderly patients. A clinically useful, minimally invasive test is likely to decrease the currently very high mortality rate and allow monitoring of 'at risk' patients during their hospital stay. A two-dimensional electrophoresis based proteomic approach was undertaken to assess plasma protein differences between patients with surgically confirmed bowel infarction and control Intensive Care patients. The major protein differences were found to be members or variants of acute phase proteins. Serum amyloid A showed the largest difference between the two patient groups, and this protein was investigated in greater depth. An analysis was performed to compare the diagnostic ability of several commonly used indicators of critical illness and bowel infarction with serum amyloid A and phospholipase A2. Although none of the variables were ideal for clinical use, plasma phospholipase A2 activity showed the best discriminatory power, as determined by Receiver Operating Characteristic curves. From a review of the literature, phospholipase AI (PLA2) appeared to be increased in the bowel as a result of ischaemia and infarction. In one patient, matched tissues were obtained, and PLA2 activity was found to be significantly higher in infarcted bowel tissue compared to ischaemic bowel tissue. PLA2 activity was significantly greater in bowel lumen than tissue, suggesting that the protein was being released, and may enter the circulation. PLA2 activity was increased in the plasma of bowel infarction patients compared with control patients, though the difference was not significant. The phospholipase activity exhibited a number of similarities to typical phospholipase A2 proteins, but also showed a number of inconsistent characteristics. For this reason, we wished to identify the protein responsible for the increased phospholipase activity in infarcted human bowel. The PLA2 activity in human bowel could not be abolished by immunoprecipitation of the PLA2 isoforms IIA (well described in bowel) and V (a closely related isoform). To investigate these proteins, a native urea protein gel devised for snake venom phospholipase A2 was modified for use with mammalian phospholipase AI. The modified gel was used to show that the protein with phospholipase activity from infarcted gut was different from normal gut PLA2 and type IIA PLA2. A number of extensions were devised for these native gels and were found to be useful both in this investigation and for venom investigations. Protein purification was undertaken to identify the protein responsible for the increased phospholipase activity in infarcted bowel. Protein was purified from infarcted human bowel using a number of techniques that exploited unusual characteristics of the protein. The purification techniques each retained the native activity of the protein and the purification could therefore be monitored with a phospholipid hydrolysis assay at each stage. The protein identified by mass spectrometry was an excellent match for cyclophilin B, an inflammatory protein that had previously been identified in rat bowel at the mRNA level (Hasel et al, 1991, Kainer & Doris, 2000). As the purification progress had been monitored throughout with a phospholipid hydrolysis assay, cyclophilin B was an unexpected identification, as it is not known to have phospholipase activity. Cyclophilin B was removed from the highly purified samples via immunoprecipitation and this process abolished all phospholipase activity. The addition of cyclosporin A, (the pharmaceutical ligand of cyclophilin B), did not effect the phospholipase activity. Cyclophilin B protein was found in normal and infarcted human bowel using Western blotting. Cyclophilin B protein also appeared to be present in the bowel lumen and plasma of several patients with bowel infarction, but not in control patients. Immunohistochemistry confirmed the ubiquitous nature of cyclophilin B that had been reported by other groups. This project has investigated the use of two dimensional gel electrophoresis based proteomics to identify proteins present in the plasma of patients with confirmed bowel infarction and control intensive care patients. The major protein classes observed were members of the acute phase proteins, which highlights the need for pre-fractionation of plasma to identify lower abundance, disease associated proteins. A series of potential plasma markers were compared using Receiver Operating Characteristic Curves. Although no ideal marker was clear from this analysis, phospholipase activity appeared to warrant further investigation. Phospholipase activity was investigated in human infarcted bowel. Protein purification identified cyclophilin B as a bowel protein that showed unusual phospholipid hydrolysing activity. Cyclophilin B is a ubiquitous protein in intestinal cell types in both normal and infarcted tissue. There appears to be release of cyclophilin B into bowel lumen and plasma under conditions of mesenteric ischaemia and infarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurement of Health-Related Quality of Life (HRQoL) of the elderly requires instruments with demonstrated sensitivity, reliability, and validity, particularly with the increasing proportion of older people entering the health care system. This article reports the psychometric properties of the 12-item Assessment of Quality of Life (AQoL) instrument in chronically ill community-dwelling elderly people with an 18-month follow-up. Comparator instruments included the SF-36 and the OARS. Construct validity of the AQoL was strong when examined via factor analysis and convergent and divergent validity against other scales. Receiver Operator Characteristic (ROC) curve analyses and relative efficiency estimates indicated the AQoL is sensitive, responsive, and had the strongest predicative validity for nursing home entry. It was also sensitive to economic prediction over the follow-up. Given these robust psychometric properties and the brevity of the scale, AQoL appears to be a suitable instrument for epidemiologic studies where HRQoL and utility data are required from elderly populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Equipped with recent advances in electronics and communication, wireless sensor networks gained a rapid development to provide reliable information with higher Quality of Service (QoS) at lower costs. This paper presents a realtime tracking system developed as a part of the ISSNIP BigNet Testbed project. Here a GPS receiver was used to acquire position information of mobile nodes and GSM technology was used as the data communication media. Moreover, Google map based data visualization software was developed to locate the mobile nodes via Internet. This system can be used to accommodate various sensors, such as temperature, pressure, pH etc., and monitor the status of the nodes.