976 resultados para Push-out test
Resumo:
In this study, an experimental investigation into the shear strength behaviour of aluminium alloy single-lap adhesive joints was carried out in order to understand the effect of temperature on the strength of adhesively bonding joints. Single lap joints (SLJs) were fabricated and tested at RT and high temperatures (100ºC, 125ºC, 150ºC, 175ºC and 200ºC). Results showed that the failure loads of the single-lap joint test specimens vary with temperature and this needs to be considered in any design procedure. It is shown that, although the tensile stress decreased with temperature, the lap-shear strength of the adhesive increased with increasing of temperature up to the glass transition of the adhesive (Tg) and decreased for tests above the Tg.
Resumo:
OBJECTIVE To investigate the factors related to the granting of preliminary court orders [injunctions] in drug litigations. METHODS A retrospective descriptive study of drug lawsuits in the State of Minas Gerais, Southeastern Brazil, was conducted from October 1999 to 2009. The database consists of 6,112 lawsuits, out of which 6,044 had motions for injunctions and 5,167 included the requisition of drugs. Those with more than one beneficiary were excluded, which totaled 5,072 examined suits. The variables for complete, partial, and suppressed motions were treated as dependent and assessed in relation to those that were independent – lawsuits (year, type, legal representation, defendant, court in which it was filed, adjudication time), drugs (level five of the anatomical therapeutic chemical classification), and diseases (chapter of the International Classification of Diseases). Statistical analyses were performed using the Chi-square test. RESULTS Out of the 5,072 lawsuits with injunctions, 4,184 (82.5%) had the injunctions granted. Granting varied from 95.8% of the total lawsuits in 2004 to 76.9% in 2008. Where there was legal representation, granting exceeded 80.0% and in lawsuits without representation, it did not exceed 66.9%. In public civil actions (89.1%), granting was higher relative to ordinary lawsuits (82.8%) and injunctions (80.1%). Federal courts granted only 68.6% of the injunctions, while the state courts granted 84.8%. Diseases of the digestive system and neoplasms received up to 87.0% in granting, while diseases of the nervous system, mental and behavioral disorders, and diseases of the skin and subcutaneous tissue received granting below 78.6% and showed a high proportion of suspended injunctions (10.9%). Injunctions involving paroxetine, somatropin, and ferrous sulfate drugs were all granted, while less than 54.0% of those involving escitalopram, sodium diclofenac, and nortriptyline were granted. CONCLUSIONS There are significant differences in the granting of injunctions, depending on the procedural and clinical variances. Important trends in the pattern of judicial action were observed, particularly, in the reduced granting [of injunctions] over the period.
Resumo:
This paper focuses on a novel formalization for assessing the five parameter modeling of a photovoltaic cell. An optimization procedure is used as a feasibility problem to find the parameters tuned at the open circuit, maximum power, and short circuit points in order to assess the data needed for plotting the I-V curve. A comparison with experimental results is presented for two monocrystalline PV modules.
Resumo:
In this work, the shear modulus and strength of the acrylic adhesive 3M® DP 8005 was evaluated by two different methods: the Thick Adherend Shear Test (TAST) and the Notched Plate Shear Method (Arcan). However, TAST standards advise the use of a special extensometer attached to the specimen, which requires a very experienced technician. In the present study, the adhesive shear displacement for the TAST was measured using an optical technique, and also with a conventional inductive extensometer of 25 mm used for tensile tests. This allowed for an assessment of suitability of using a conventional extensometer to measure this parameter. Since the results obtained by the two techniques are identical, it can be concluded that using a conventional extensometer is a valid option to obtain the shear modulus for the particular adhesive used. In the Arcan tests, the adhesive shear displacement was only measured using the optical technique. This work also aimed the comparison of shear modulus and strength obtained by the TAST and Arcan test methods.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores.Área de Especialização de Sistemas Autónomos
Resumo:
ABSTRACT OBJECTIVE : To analyze if the demographic and socioeconomic variables, as well as percutaneous coronary intervention are associated with the use of medicines for secondary prevention of acute coronary syndrome. METHODS : In this cohort study, we included 138 patients with acute coronary syndrome, aged 30 years or more and of both sexes. The data were collected at the time of hospital discharge, and after six and twelve months. The outcome of the study was the simultaneous use of medicines recommended for secondary prevention of acute coronary syndrome: platelet antiaggregant, beta-blockers, statins and angiotensin-converting-enzyme inhibitor or angiotensin receptor blocker. The independent variables were: sex, age, education in years of attending, monthly income in tertiles and percutaneous coronary intervention. We described the prevalence of use of each group of medicines with their 95% confidence intervals, as well as the simultaneous use of the four medicines, in all analyzed periods. In the crude analysis, we verified the outcome with the independent variables for each period through the Chi-square test. The adjusted analysis was carried out using Poisson Regression. RESULTS : More than a third of patients (36.2%; 95%CI 28.2;44.3) had the four medicines prescribed at the same time, at the moment of discharge. We did not observe any differences in the prevalence of use in comparison with the two follow-up periods. The most prescribed class of medicines during discharge was platelet antiaggregant (91.3%). In the crude analysis, the demographic and socioeconomic variables were not associated to the outcome in any of the three periods. CONCLUSIONS : The prevalence of simultaneous use of medicines at discharge and in the follow-ups pointed to the under-utilization of this therapy in clinical practice. Intervention strategies are needed to improve the quality of care given to patients that extend beyond the hospital discharge, a critical point of transition in care.
Resumo:
The use of fiber reinforced plastics has increased in the last decades due to their unique properties. Advantages of their use are related with low weight, high strength and stiffness. Drilling of composite plates can be carried out in conventional machinery with some adaptations. However, the presence of typical defects like delamination can affect mechanical properties of produced parts. In this paper delamination influence in bearing stress of drilled hybrid carbon+glass/epoxy quasi-isotropic plates is studied by using image processing and analysis techniques. Results from bearing test show that damage minimization is an important mean to improve mechanical properties of the joint area of the plate. The appropriateness of the image processing and analysis techniques used in the measurement of the damaged area is demonstrated.
Resumo:
In this work, an experimental study was performed on the influence of plug filling, loading rate and temperature on the tensile strength of single-strap (SS) and double-strap (DS) repairs on aluminium structures. The experimental programme includes repairs with different values of overlap length (LO=10, 20 and 30 mm), and with and without plug filling. The influence of the testing speed on the repairs strength is also addressed (considering 0.5, 5 and 25 mm/min). Accounting for the temperature effects, tests were carried out at room temperature, 50ºC and 80ºC. This will permit a comparative evaluation of the adhesive tested below and above the Glass Transition Temperature (Tg), established by the manufacturer at 67ºC. The global tendencies of the test results concerning the plug filling and overlap length analyses are interpreted from the fracture modes and typical stress distributions for bonded repairs. According to the results obtained from this work, design guidelines for repairing aluminium structures were recommended.
Resumo:
This paper proposes an online mechanism that can evaluate the sensitivity of single event upsets (SEUs) of field programmable gate arrays (FPGAs). The online detection mechanism cyclically reads and compares the values form the external and internal configuration memories, taking into account the mask information. This remote detection method also signals any mismatch as a result of a SEU that affects both used and not-used FPGA parts, which maximizes the monitored area. By utilizing an external, Web-accessible controller that is connected to the test infrastructure, the possibility of running the same operation in a remote manner is enabled. Moreover, the need for a local memory to store the mask values is also eliminated.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
OBJECTIVE Analyze the profile of women, in health services, who carry out treatment for smoking cessation.METHODS Systematic review that used the following sources of information: Cummulative Index to Nursing and Allied Health Literature (CINAHL), PubMed,Biblioteca Virtual em Saúde (BVS), Scopus and Web of Science. We included quantitative studies that addressed the characterization of women, in health services, who carried out treatment for smoking cessation, resulting in 12 articles for analysis. The assessment of the methodological quality of the studies was performed using the instrument MAStARI from Joanna Briggs Institute.RESULTS The predominant profile of women who carried out treatment for smoking cessation in health services was composed of white, married, employed, and highly level educated women. Women who carried out the treatment for smoking cessation in specialized services had a more advanced age, were white, were married and had a diagnosis of depression. The quality level of most studies was moderate.CONCLUSIONS The profile of women who carry out treatment for smoking cessation, either in general or specialized health services, is composed of white, married, and highly level educated women. Publications about smoking women are scarce and the lack of Brazilian studies characterizing the profile of women who start treatment for smoking cessation shows the need for studies that explore this subject.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Diagnóstico e Intervenção Organizacional e Comunitária
Resumo:
The increasing complexity of VLSI circuits and the reduced accessibility of modern packaging and mounting technologies restrict the usefulness of conventional in-circuit debugging tools, such as in-circuit emulators for microprocessors and microcontrollers. However, this same trend enables the development of more complex products, which in turn require more powerful debugging tools. These conflicting demands could be met if the standard scan test infrastructures now common in most complex components were able to match the debugging requirements of design verification and prototype validation. This paper analyses the main debug requirements in the design of microprocessor-based applications and the feasibility of their implementation using the mandatory, optional and additional operating modes of the standard IEEE 1149.1 test infrastructure.
Resumo:
Thesis submitted to the Faculdade de Ciências e Tecnologia to obtain the Master’s degree in Environmental Engineering, profile in Ecological Engineering