953 resultados para Propofol Anesthesia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Psicologia do Desenvolvimento e Aprendizagem - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the accidents with biological material among medical students interning in a trauma emergency room and identify key related situations, attributed causes and prevention. METHODS: we conducted a study with a quantitative approach. Data were collected through a questionnaire applied via internet, with closed, multiple-choice questions regarding accidents with biological material. The sample comprised 100 students. RESULTS: thirty-two had accidents with biological material. Higher-risk activities were local anesthesia (39.47%), suture (18.42%) and needle recapping (15.79%). The main routes of exposure to biological material were the eyes or mucosa, with 34%, and syringe needle puncture, with 45%. After contamination, only 52% reported the accident to the responsible department. CONCLUSION: The main causes of accidents and routes of exposure found may be attributed to several factors, such as lack of training and failure to use personal protective equipment. Educational and preventive actions are extremely important to reduce the incidence of accidents with biological materials and improve the conduct of post-exposure. It is important to understand the main causes attributed and situations related, so as general and effective measures can be applied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The volume-controlled mechanical ventilation and spontaneous ventilation, through haemogasometric, cardiovascular and spirometry variables were evaluated. Twenty-eight rabbits were distributed into two groups: GIVC (isoflurane and volume-controlled ventilation), GIVE (isoflurane and spontaneous ventilation), GSVC (sevoflurane and volume-controlled ventilation) and GSVE (sevoflurane and spontaneous ventilation). Induction was performed by mask with isoflurane (GIVE and GIVC) or sevoflurane (GSVE and GSVC) at 1.5 MAC in 100% oxygen. To maintain anesthesia, MAC was reset to 1. In GIVC and GSVC groups, rocuronium was administered at a dose of 0.6 mg/kg followed by its continuous infusion (0.6 mg/kg/h). In GSVE and GIVE, 0.9% NaCl was administered instead of rocuronium. Controlled ventilation was started by adjusting the capnometry in order to obtain values between 35 and 45 mmHg. Parameters were measured 60 minutes after induction of anesthesia (M0), 15 minutes after the bolus of rocuronium or 0.9% NaCl (M15) and every fifteen minutes (M30, M45 and M60). Hypercapnia and acidosis was evident in GIVC, GSVC and GSVE. We concluded that the volume-controlled mechanical ventilation was not able to maintain normocapnia in rabbits, producing acidosis in them, especially when using sevoflurane. The use of isoflurane showed greater stability than the sevoflurane anesthetic in the species studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Subarachnoid infusion of most contrast mediums and the steps involved in performing a cervical myelography have adverse affects that can discourage its use in the radiographic diagnosis of spinal cord diseases. Thus, the cardiovascular and respiratory alterations associated with neck flexion, subarachnoid puncture, and cerebrospinal fluid drainage during subarachnoid infusion of ioversol (320mgI/mL) in dogs under general anesthesia using isoflurane were evaluated. The dogs received subarachnoid infusion of autologous cerebrospinal fluid kept at 38°C - control group (GC); ioversol 0.3mL/kg at 25°C (GI25) and ioversol 0.3mL/kg heated to 38°C (GI38). Each dog had its heart rate (HR), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), respiratory rate (RR), oxyhemoglobin saturation (SaO2) and electrocardiography readings (PR and QT intervals) recorded. Group comparisons showed no statistical difference regarding neck positioning, subarachnoid puncture, and subarachnoid infusion of contrast medium on HR, RR and SaO2, cardiac rhythm or conduction. However, isoflurane significantly increased PR and QT intervals. Based on these findings, it is concluded that the steps involved in cervical myelography and the use of ioversol 320mgI/mL at 0.3mL/kg (25ºC and 38ºC) during cervical myelography did not result in relevant cardiovascular and respiratory alterations, except for an elevation in arterial pressure after injection of ioversol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE:To assess the hemodynamic changes and bispectral index (BIS) following administration of a continuous rate infusion (CRI) of butorphanol in isoflurane-anesthetized calves.METHODS: Eight calves weighing 110 ± 12 kg were included in the study. Anesthesia was induced with 5% isoflurane in O2 delivered via face mask and maintained with end-tidal concentration of 1.4%. IPPV was set to a peak inspiratory airway pressure of 15 cmH2O and respiratory rate of six breaths minute-1. Forty minutes after the start of anesthetic maintenance, 0.1 mg kg-1butorphanol was administered intravenously, followed by a CRI of 20 µg kg-1 minute-1. Hemodynamic variables and BIS were recorded before butorphanol administration (T0), and at 10, 20, 40 and 80 minutes following the CRI. Anesthesia was discontinued after the last recording and the calves were allowed to recover. The time to sternal recumbency (SRE) and standing (ST) were evaluated.RESULTS: There were no significant differences between the moments in all hemodynamic variables and BIS. The time to SRE and ST was 9 ± 5 and 14 ± 7 minutes, respectively.CONCLUSION: The continuous rate infusion did not produce clinically relevant changes in hemodynamic or bispectral index values compared to baseline in mechanically ventilated and unstimulated calves anesthetized at 1.4% isoflurane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This survey was conducted with the objective of developing and adapting diagnostic techniques in neurology for non-human primates, of the species Alouatta guariba Geoffroy Saint-Hilaire, 1812 (howler monkey) healthy and kept in captivity. Physical-chemical analyses were carried out in cerebrospinal fluid and its pressure measurement in the cisterna magna. Eight animals were used for the analysis of cerebrospinal fluid. In all procedures, were used chemical restraint and anesthesia with ketamine, xylazine and association of midazolam and inhalational anesthesia with isoflurane for carrying out the spinal tap. The cerebrospinal fluid analysis showed average values: protein: 16.92±9.84; glucose: 131.25mg/dL±106.7; pH: 8.37±0.69; nucleated cells: 0.5/mm³±0.75; red blood cells: 49.37/mm³±111.76 and CSF cisternal pressure: 7.37cm H2O±1.77. This study demonstrated the safety and efficacy of cerebrospinal fluid collection in the cisterna magna of Alouatta guariba, and the reference values for the specie.