976 resultados para Pressure method
Resumo:
This paper addresses the problem of optimal positioning of surface bonded piezoelectric patches in sandwich plates with viscoelastic core and laminated face layers. The objective is to maximize a set of modal loss factors for a given frequency range using multiobjective topology optimization. Active damping is introduced through co-located negative velocity feedback control. The multiobjective topology optimization problem is solved using the Direct MultiSearch Method. An application to a simply supported sandwich plate is presented with results for the maximization of the first six modal loss factors. The influence of the finite element mesh is analyzed and the results are, to some extent, compared with those obtained using alternative single objective optimization.
Resumo:
Thin Solid Films, vol. 427, nº 1-2
Resumo:
The behavior of robotic manipulators with backlash is analyzed. Based on the pseudo-phase plane two indices are proposed to evaluate the backlash effect upon the robotic system: the root mean square error and the fractal dimension. For the dynamical analysis the noisy signals captured from the system are filtered through wavelets. Several tests are developed that demonstrate the coherence of the results.
Resumo:
One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.
Resumo:
One important step in the design of air stripping operations for the removal of VOC is the choice of operating conditions, which are based in the phase ratio. This parameter sets on directly the stripping factor and the efficiency of the operation. Its value has an upper limit determined by the flooding regime, which is previewed using empirical correlations, namely the one developed by Eckert. This type of approach is not suitable for the development of algorithms. Using a pilot scale column and a convenient solution, the pressure drop was determined in different operating conditions and the experimental values were compared with the estimations. This particular research will be incorporated in a global model for simulating the dynamics of air stripping using a multi variable distributed parameter system.
Resumo:
The development and applications of thermoset polymeric composites, namely fibre reinforced plastics (FRP), have shifted in the last decades more and more into the mass market [1]. Despite of all advantages associated to FRP based products, the increasing production and consume also lead to an increasing amount of FRP wastes, either end-of-lifecycle products, or scrap and by-products generated by the manufacturing process itself. Whereas thermoplastic FRPs can be easily recycled, by remelting and remoulding, recyclability of thermosetting FRPs constitutes a more difficult task due to cross-linked nature of resin matrix. To date, most of the thermoset based FRP waste is being incinerated or landfilled, leading to negative environmental impacts and supplementary added costs to FRP producers and suppliers. This actual framework is putting increasing pressure on the industry to address the options available for FRP waste management, being an important driver for applied research undertaken cost efficient recycling methods. [1-2]. In spite of this, research on recycling solutions for thermoset composites is still at an elementary stage. Thermal and/or chemical recycling processes, with partial fibre recovering, have been investigated mostly for carbon fibre reinforced plastics (CFRP) due to inherent value of carbon fibre reinforcement; whereas for glass fibre reinforced plastics (GFRP), mechanical recycling, by means of milling and grinding processes, has been considered a more viable recycling method [1-2]. Though, at the moment, few solutions in the reuse of mechanically-recycled GFRP composites into valueadded products are being explored. Aiming filling this gap, in this study, a new waste management solution for thermoset GFRP based products was assessed. The mechanical recycling approach, with reduction of GFRP waste to powdered and fibrous materials was applied, and the potential added value of obtained recyclates was experimentally investigated as raw material for polyester based mortars. The use of a cementless concrete as host material for GFRP recyclates, instead of a conventional Portland cement based concrete, presents an important asset in avoiding the eventual incompatibility problems arisen from alkalis silica reaction between glass fibres and cementious binder matrix. Additionally, due to hermetic nature of resin binder, polymer based concretes present greater ability for incorporating recycled waste products [3]. Under this scope, different GFRP waste admixed polymer mortar (PM) formulations were analyzed varying the size grading and content of GFRP powder and fibre mix waste. Added value of potential recycling solution was assessed by means of flexural and compressive loading capacities of modified mortars with regard to waste-free polymer mortars.
Resumo:
Undesirable void formation during the injection phase of the liquid composite molding process can be understood as a consequence of the non-uniformity of the flow front progression, caused by the dual porosity of the fiber perform. Therefore the best examination of the void formation physics can be provided by a mesolevel analysis, where the characteristic dimension is given by the fiber tow diameter. In mesolevel analysis, liquid impregnation along two different scales; inside fiber tows and within the spaces between them; must be considered and the coupling between these flow regimes must be addressed. In such case, it is extremely important to account correctly for the surface tension effects, which can be modeled as capillary pressure applied at the flow front. When continues Galerkin method is used, exploiting elements with velocity components and pressure as nodal variables, strong numerical implementation of such boundary conditions leads to ill-posing of the problem, in terms of the weak classical as well as stabilized formulation. As a consequence, there is an error in mass conservation accumulated especially along the free flow front. This article presents a numerical procedure, which was formulated and implemented in the existing Free Boundary Program in order to significantly reduce this error.
Resumo:
Naturally Occurring Radioactive Materials (NORM) are materials that are found naturally in the environment and contain radioactive isotopes that can cause negative effects on the health of workers who manipulate them. Present in underground work like mining and tunnel construction in granite zones, these materials are difficult to identify and characterize without appropriate equipment for risk evaluation. The assessing methods were exemplified with a case study applied to the handling and processing of phosphoric rock where one found significant amounts of radioactive isotopes and consequently elevated radon concentrations in enclosed spaces containing these materials. © 2015 Taylor & Francis Group, London.
Resumo:
A low cost method (LCM) to produce a gaseous environment for the isolation of Helicobacter pylori, was compared with the standard Gas Park system. The LCM uses a carbonated antacid tablet, a plastic bag with tap water, a candle, and a wide-mouthed glass jar provided with a tight-fitting metalic screw cap and a rubber gasket. Antral gastric biopsies from 153 cases were incubated by duplicate on blood agar plates and treated with the two methods. In 95 cases the agent was isolated from both, and only from the standard method in 10 cases; the opposite condition was found in five cases, and 43 were negative. That difference is not significant (Pearson's X²= 93.25 p > 0,05)
Resumo:
Reporter genes are routinely used in every laboratory for molecular and cellular biology for studying heterologous gene expression and general cellular biological mechanisms, such as transfection processes. Although well characterized and broadly implemented, reporter genes present serious limitations, either by involving time-consuming procedures or by presenting possible side effects on the expression of the heterologous gene or even in the general cellular metabolism. Fourier transform mid-infrared (FT-MIR) spectroscopy was evaluated to simultaneously analyze in a rapid (minutes) and high-throughput mode (using 96-wells microplates), the transfection efficiency, and the effect of the transfection process on the host cell biochemical composition and metabolism. Semi-adherent HEK and adherent AGS cell lines, transfected with the plasmid pVAX-GFP using Lipofectamine, were used as model systems. Good partial least squares (PLS) models were built to estimate the transfection efficiency, either considering each cell line independently (R 2 ≥ 0.92; RMSECV ≤ 2 %) or simultaneously considering both cell lines (R 2 = 0.90; RMSECV = 2 %). Additionally, the effect of the transfection process on the HEK cell biochemical and metabolic features could be evaluated directly from the FT-IR spectra. Due to the high sensitivity of the technique, it was also possible to discriminate the effect of the transfection process from the transfection reagent on KEK cells, e.g., by the analysis of spectral biomarkers and biochemical and metabolic features. The present results are far beyond what any reporter gene assay or other specific probe can offer for these purposes.
Resumo:
The most common techniques for stress analysis/strength prediction of adhesive joints involve analytical or numerical methods such as the Finite Element Method (FEM). However, the Boundary Element Method (BEM) is an alternative numerical technique that has been successfully applied for the solution of a wide variety of engineering problems. This work evaluates the applicability of the boundary elem ent code BEASY as a design tool to analyze adhesive joints. The linearity of peak shear and peel stresses with the applied displacement is studied and compared between BEASY and the analytical model of Frostig et al., considering a bonded single-lap joint under tensile loading. The BEM results are also compared with FEM in terms of stress distributions. To evaluate the mesh convergence of BEASY, the influence of the mesh refinement on peak shear and peel stress distributions is assessed. Joint stress predictions are carried out numerically in BEASY and ABAQUS®, and analytically by the models of Volkersen, Goland, and Reissner and Frostig et al. The failure loads for each model are compared with experimental results. The preparation, processing, and mesh creation times are compared for all models. BEASY results presented a good agreement with the conventional methods.
Resumo:
Adhesive bonding is nowadays a serious candidate to replace methods such as fastening or riveting, because of attractive mechanical properties. As a result, adhesives are being increasingly used in industries such as the automotive, aerospace and construction. Thus, it is highly important to predict the strength of bonded joints to assess the feasibility of joining during the fabrication process of components (e.g. due to complex geometries) or for repairing purposes. This work studies the tensile behaviour of adhesive joints between aluminium adherends considering different values of adherend thickness (h) and the double-cantilever beam (DCB) test. The experimental work consists of the definition of the tensile fracture toughness (GIC) for the different joint configurations. A conventional fracture characterization method was used, together with a J-integral approach, that take into account the plasticity effects occurring in the adhesive layer. An optical measurement method is used for the evaluation of crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab® sub-routine for the automated extraction of these quantities. As output of this work, a comparative evaluation between bonded systems with different values of adherend thickness is carried out and complete fracture data is provided in tension for the subsequent strength prediction of joints with identical conditions.
Resumo:
This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 μg kg−1 for fluazifop-pbutyl to 50 μg kg−1 for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.
Resumo:
Dissertação apresentada para a obtenção do grau de Mestre em Engenharia do Ambiente, Perfil Engenharia Sanitária
Resumo:
Resumo Objectivos: Avaliação da Tosse em doentes com Doença Pulmonar Obstrutiva Crónica (DPOC). Identificar e determinar a relação dos factores preditivos que contribuem para a deterioração da capacidade de tosse nestes indivíduos. Tipo de estudo: Estudo observacional descritivo de natureza transversal. Definição dos casos: Os critérios de diagnóstico da DPOC são o quadro clínico e o Gold standard para diagnóstico da DPOC – a espirometria. População-alvo: Todos os utentes com patologia primária de DPOC diagnosticada que se desloquem ao serviço de função respiratória do Hospital de Viseu, para realizar provas. Método de Amostragem: Foi utilizada uma amostra aleatória constituída por todos os indivíduos, que cumpriram os critérios de inclusão, conscientes e colaborantes, que aceitaram participar neste estudo. Dimensão da amostra: Uma amostra de 55 indivíduos que se deslocaram ao serviço de função respiratória, entre Janeiro e Junho de 2009, para realizar provas de função respiratória. Condução do estudo: Os utentes que aceitaram participar neste estudo foram sujeitos a um questionário de dados clínicos e realizaram 5 testes: índice de massa corporal (IMC), estudo funcional respiratório e gasometria arterial, avaliação da força dos músculos respiratórios (PImax e PEmax) e avaliação do débito máximo da tosse (Peak Cough Flow). Análise estatística: Foram obtidos dados caracterizadores da amostra em estudo, sendo posteriormente correlacionado o valor de débito máximo da tosse (Peak Cough Flow) com os resultados obtidos para as avaliações do IMC, estudo funcional respiratório, PImax e PEmax, gasometria, avaliação da capacidade de Tosse e número de internamentos no último ano por agudização da DPOC. Tendo sido encontrados os valores de correlação entre o Peak Cough Flow e os restantes parâmetros. Resultados: Após análise dos resultados, foram obtidos os valores de Peak Cough Flow para a população com DPOC e verificou-se valores diminuídos em comparação com os valores normais da população, tendo-se verificado maiores valores de PCF em indivíduos do sexo masculino, em comparação aos valores do sexo feminino. Foi analisada a relação entre o PCF e a idade, peso, altura e IMC, não tendo sido encontrada relação, dado que a tosse não apresenta uma variação segundo os valores antropométricos, tal como a relação com os valores espirométricos. Quanto aos parâmetros funcionais respiratórios foram analisadas as relações com o PCF. Verificou-se relações significativas entre o PCF e o FEV1, a FVC, o PEF, apresentando uma relação positiva, onde maiores valores destes parâmetros estão correlacionados com maiores picos de tosse. Quanto a RAW e RV, o PCF apresenta uma relação negativa, onde uma maior resistência da via aérea ou doentes mais hiperinsuflados leva a menores valores de PCF. Por outro lado não foi encontrada relação entre o PCF e a FRC e o TLC. Quanto à força dos músculos respiratórios, verificou-se relação significativa com o PImax e a PEmax em que a fraqueza ao nível dos músculos respiratórios contribuem para um menor valor de PCF. Relativamente aos valores da gasometria arterial, verificou-se relação entre o PCF e a PaO2 de forma positiva, em que doentes hipoxémicos apresentam menores valores de tosse, e a PaCO2, de forma negativa, em que os doentes hipercápnicos apresentam menores valores de PCF tendo sido verificada relação entre o PCF e o pH e sO2. Quanto à relação entre o número de internamentos por agudização da DPOC no último ano e o PCF verificou-se uma relação significativa, onde um menor valor de PCF contribui para uma maior taxa de internamento por agudização da DPOC. Conclusão: Este conjunto de conclusões corrobora a hipótese inicialmente formulada, de que o Peak Cough Flow se encontra diminuído nos indivíduos com Doença Pulmonar Obstrutiva Crónica onde a variação do PCF se encontra directamente relacionada com os parâmetros funcionais respiratórios, com a força dos músculos respiratórios e com os valores de gasometria arterial. ABSTRACT: Aims: Cough evaluation in Chronic Obstructive Pulmonary Disease (COPD) patients. Identify and determine the relation of the predictive factors that contribute to the cough capacity degradation in this type of patients. Type of study: Descriptive observational study of transversal nature. Case definition: The COPD diagnosis criteria are the clinical presentation and the gold standard to the COPD diagnosis- the Spirometry. Target Population: Every patients, with primary pathology of COPD diagnosed, who went to the respiratory function service of Viseu hospital to perform tests. Sampling Method: It was used a random sample constituted by all the, conscious and cooperating individuals, who complied with the inclusion criteria and who accepted to make part of this study. Sample size: A sample of 55 individuals that went to the respiratory function service between January and June 2009 to perform respiratory function tests. Study: The patients who accepted to make part of this study were submitted to a clinical data questionary and performed 5 tests: body mass index (BMI), respiratory functional study, arterial blood gas level, evaluation of respiratory muscles strength (maximal inspiratory pressure (MIP) and maximum expiratory pressure (MEP)), and Peak Cough Flow evaluation. Statistic Analysis: Were obtained characterizing data of the sample in study, and later correlated the value of the Peak Cough Flow with the results from the evaluation of the body mass index (BMI), the respiratory functional study the MIP and MEP, the arterial blood gas level and also with the ability to cough evaluation and the number of hospitalizations in the last year for COPD exacerbations. The values of correlation between the Peak Cough Flow and the other parameters were found. Results: After analyzing the results, were obtained the values of Peak Cough Flow for the population with COPD. There were decreased values compared with the population normal values, having been found higher values of PCF in males compared to female values. It was analyzed the relation between the PCF and the age, weight, height and BMI but no relation was found on account of the fact that the cough does not show a variation according to anthropometric parameters, such as the relation with spirometric values. As for the respiratory functional parameters were analyzed relations with the PCF. There were significant relations between the PCF and FEV1, the FVC, the PEF, presenting a positive relation, where higher values of these parameters are correlated with higher incidence of cough. Concerning the RAW and RV, the PCF has a negative relation, in which a higher airway resistance or in more hyperinflated patients, leads to lower values of PCF. On the other hand no correlation was found between the PCF and the FRC and TLC. Regarding the respiratory muscle strength, there was a significant relation with the MIP and MEP, in which the weakness at the level of respiratory muscles contribute to a lower value of PCF. For values of arterial blood gas level, there was no relation between the PCF and PaO2, in a positive way, in which patients with hypoxemia present lower values of cough, and PaCO2, in a negative way in which hypercapnic patients had lower values of PCF, having being founded a relation between the PCF and the pH and sO2. As for the relation between the number of hospitalizations for COPD exacerbation in the last year and the PCF was found a significant relation, in which a smaller value of PCF contributes to a higher rate of hospitalization for COPD exacerbation. Conclusion: This set of findings supports the hypothesis first formulated that Peak Cough Flow is decreased in individuals with Chronic Obstructive Pulmonary Disease, in which the variation of the PCF is directly related to the respiratory function parameters, the strength of respiratory muscles and the values of arterial blood gases.