910 resultados para Prediction method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the new KDIGO (Kidney Disease Improving Global Outcomes) guidelines, the term of renal osteodystrophy, should be used exclusively in reference to the invasive diagnosis of bone abnormalities. Due to the low sensitivity and specificity of biochemical serum markers of bone remodelling,the performance of bone biopsies is highly stimulated in dialysis patients and after kidney transplantation. The tartrate-resistant acid phosphatase (TRACP) is an iso-enzyme of the group of acid phosphatases, which is highly expressed by activated osteoclasts and macrophages. TRACP in osteoclasts is in intracytoplasmic vesicles that transport the products of bone matrix degradation. Being present in activated osteoclasts, the identification of this enzyme by histochemistry in undecalcified bone biopsies is an excellent method to quantify the resorption of bone. Since it is an enzymatic histochemical method for a thermolabile enzyme, the temperature at which it is performed is particularly relevant. This study aimed to determine the optimal temperature for identification of TRACP in activated osteoclasts in undecalcified bone biopsies embedded in methylmethacrylate. We selected 10 cases of undecalcified bone biopsies from hemodialysis patients with the diagnosis of secondary hyperparathyroidism. Sections of 5 μm were stained to identify TRACP at different incubation temperatures (37º, 45º, 60º, 70º and 80ºC) for 30 minutes. Activated osteoclasts stained red and trabecular bone (mineralized bone) was contrasted with toluidine blue. This approach also increased the visibility of the trabecular bone resorption areas (Howship lacunae). Unlike what is suggested in the literature and in several international protocols, we found that the best results were obtained with temperatures between 60ºC and 70ºC. For technical reasons and according to the results of the present study, we recommended that, for an incubation time of 30 minutes, the reaction should be carried out at 60ºC. As active osteoclasts are usually scarce in a bone section, the standardization of the histochemistry method is of great relevance, to optimize the identification of these cells and increase the accuracy of the histomosphometric results. Our results, allowing an increase in osteoclasts contrast, also support the use of semi-automatic histomorphometric measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antifungal activities of fluconazole, itraconazole, ketoconazole, terbinafine and griseofulvin were tested by broth microdilution technique, against 60 dermatophytes isolated from nail or skin specimens from Goiania city patients, Brazil. In this study, the microtiter plates were incubated at 28 ºC allowing a reading of the minimal inhibitory concentration (MIC) after four days of incubation for Trichophyton mentagrophytes and five days for T. rubrum and Microsporum canis. Most of the dermatophytes had uniform patterns of susceptibility to the antifungal agents tested. Low MIC values as 0.03 µg/mL were found for 33.3%, 31.6% and 15% of isolates for itraconazole, ketoconazole and terbinafine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new iterative algorithm based on the inexact-restoration (IR) approach combined with the filter strategy to solve nonlinear constrained optimization problems is presented. The high level algorithm is suggested by Gonzaga et al. (SIAM J. Optim. 14:646–669, 2003) but not yet implement—the internal algorithms are not proposed. The filter, a new concept introduced by Fletcher and Leyffer (Math. Program. Ser. A 91:239–269, 2002), replaces the merit function avoiding the penalty parameter estimation and the difficulties related to the nondifferentiability. In the IR approach two independent phases are performed in each iteration, the feasibility and the optimality phases. The line search filter is combined with the first one phase to generate a “more feasible” point, and then it is used in the optimality phase to reach an “optimal” point. Numerical experiences with a collection of AMPL problems and a performance comparison with IPOPT are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method used by YAGYU et al. for the subtype-specific polymerase chain reaction (PCR) amplification of the gp41 transmembrane region of the human immunodeficiency virus type-1 (HIV-1) env gene, was tested. HIV-1 proviral DNA from 100 infected individuals in Itajaí, South Brazil was used to analyze this method. Seventy individuals were determined according to this method as having PCR products at the expected size for subtypes B, C, D and F. Of these individuals, 26 (37.1%) were observed as having the expected amplification for subtype C, and 42 (60%) were observed as having the expected products for subtypes B and D. Of the subtype B and D amplicons, 16 (22.9%) were classified as subtype D, and 26 (37.1%) were classified as subtype B. Two individuals (2.9%) had amplicons that were observed after subtype F-specific amplification was performed. Sequencing and comparing the patient sequences to reference sequences confirmed the classification of sequences of subtypes C and B. However, sequences that were falsely determined as being D and F in the PCR assay were determined as being subtypes C and B, respectively, by sequence analysis. For those individuals from whom no amplified products were obtained, a low viral load that was indicated in their patient history may explain the difficulty in subtyping by PCR methods. This issue was demonstrated by the results of ANOVA when testing the effect of viral load on the success of PCR amplification. The alignment of the obtained sequences with HIV-1 reference sequences demonstrated that there is high intra-subtype diversity. This indicates that the subtype-specific primer binding sites were not conserved or representative of the subtypes that are observed in the Brazilian populations, and that they did not allow the correct classification of HIV-1 subtypes. Therefore, the proposed method by YAGYU et al. is not applicable for the classification of Brazilian HIV-1 subtypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os adesivos têm sido alvo de estudo ao longo dos últimos anos para ligação de componentes a nível industrial. Devido à crescente utilização das juntas adesivas, torna-se necessária a existência de modelos de previsão de resistência que sejam fiáveis e robustos. Neste âmbito, a determinação das propriedades dos adesivos é fundamental para o projeto de ligações coladas. Uma abordagem recente consiste no uso de modelos de dano coesivo (MDC), que permitem simular o comportamento à fratura das juntas de forma bastante fiável. Esta técnica requer a definição das leis coesivas em tração e corte. Estas leis coesivas dependem essencialmente de 2 parâmetros: a tensão limite e a tenacidade no modo de solicitação respetivo. O ensaio End-Notched Flexure (ENF) é o mais utilizado para determinar a tenacidade em corte, porque é conhecido por ser o mais expedito e fiável para caraterizar este parâmetro. Neste ensaio, os provetes são sujeitos a flexão em 3 pontos, sendo apoiados nas extremidades e solicitados no ponto médio para promover a flexão entre substratos, o que se reflete numa solicitação de corte no adesivo. A partir deste ensaio, e após de definida a tenacidade em corte (GIIc), existem alguns métodos para estimativa da lei coesiva respetiva. Nesta dissertação são definidas as leis coesivas em corte de três adesivos estruturais através do ensaio ENF e um método inverso de ajuste dos dados experimentais. Para o efeito, foram realizados ensaios experimentais considerado um adesivo frágil, o Araldite® AV138, um adesivo moderadamente dúctil, o Araldite® 2015 e outro dúctil, o SikaForce® 7752. O trabalho experimental consistiu na realização dos ensaios ENF e respetivo tratamento dos dados para obtenção das curvas de resistência (curvas-R) através dos seguintes métodos: Compliance Calibration Method (CCM), Direct Beam Theory (DBT), Corrected Beam Theory (CBT) e Compliance-Based Beam Method (CBBM). Os ensaios foram simulados numericamente pelo código comercial ABAQUS®, recorrendo ao Métodos de Elementos Finitos (MEF) e um MDC triangular, com o intuito de estimar a lei coesiva de cada um dos adesivos em solicitação de corte. Após este estudo, foi feita uma análise de sensibilidade ao valor de GIIc e resistência coesiva ao corte (tS 0), para uma melhor compreensão do efeito destes parâmetros na curva P- do ensaio ENF. Com o objetivo de testar adequação dos 4 métodos de obtenção de GIIc usados neste trabalho, estes foram aplicados a curvas P- numéricas de cada um dos 3 adesivos, e os valores de GIIc previstos por estes métodos comparados com os respetivos valores introduzidos nos modelos numéricos. Como resultado do trabalho realizado, conseguiu-se obter uma lei coesiva única em corte para cada um dos 3 adesivos testados, que é capaz de reproduzir com precisão os resultados experimentais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To empirically test, based on a large multicenter, multinational database, whether a modified PIRO (predisposition, insult, response, and organ dysfunction) concept could be applied to predict mortality in patients with infection and sepsis. DESIGN: Substudy of a multicenter multinational cohort study (SAPS 3). PATIENTS: A total of 2,628 patients with signs of infection or sepsis who stayed in the ICU for >48 h. Three boxes of variables were defined, according to the PIRO concept. Box 1 (Predisposition) contained information about the patient's condition before ICU admission. Box 2 (Injury) contained information about the infection at ICU admission. Box 3 (Response) was defined as the response to the infection, expressed as a Sequential Organ Failure Assessment score after 48 h. INTERVENTIONS: None. MAIN MEASUREMENTS AND RESULTS: Most of the infections were community acquired (59.6%); 32.5% were hospital acquired. The median age of the patients was 65 (50-75) years, and 41.1% were female. About 22% (n=576) of the patients presented with infection only, 36.3% (n=953) with signs of sepsis, 23.6% (n=619) with severe sepsis, and 18.3% (n=480) with septic shock. Hospital mortality was 40.6% overall, greater in those with septic shock (52.5%) than in those with infection (34.7%). Several factors related to predisposition, infection and response were associated with hospital mortality. CONCLUSION: The proposed three-level system, by using objectively defined criteria for risk of mortality in sepsis, could be used by physicians to stratify patients at ICU admission or shortly thereafter, contributing to a better selection of management according to the risk of death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Qualquer estrutura hoje em dia deve ser resistente, robusta e leve, o que aumentou o interesse industrial e investigação nas ligações adesivas, nomeadamente pela melhoria das propriedades de resistência e fratura dos materiais. Com esta técnica de união, o projeto de estruturas pode ser orientado para estruturas mais leves, não só em relação à economia direta de peso relativamente às juntas aparafusas ou soldadas, mas também por causa da flexibilidade para ligar materiais diferentes. Em qualquer área da indústria, a aplicação em larga escala de uma determinada técnica de ligação supõe que estão disponíveis ferramentas confiáveis para o projeto e previsão da rotura. Neste âmbito, Modelos de Dano Coesivo (MDC) são uma ferramenta essencial, embora seja necessário estimar as leis MDC do adesivo à tração e corte para entrada nos modelos numéricos. Este trabalho avalia o valor da tenacidade ao corte (GIIC) de juntas coladas para três adesivos com ductilidade distinta. O trabalho experimental consiste na caracterização à fratura ao corte da ligação adesiva por métodos convencionais e pelo Integral-J. Além disso, pelo integral-J, é possível definir a forma exata da lei coesiva. Para o integral-J, é utilizado um método de correlação de imagem digital anteriormente desenvolvido para a avaliação do deslocamento ao corte do adesivo na extremidade da fenda (δs) durante o ensaio, acoplado a uma sub-rotina em Matlab® para a extração automática de δs. É também apresentado um trabalho numérico para avaliar a adequabilidade de leis coesivas triangulares aproximadas em reproduzir as curvas força-deslocamento (P-δ) experimentais dos ensaios ENF. Também se apresenta uma análise de sensibilidade para compreender a influência dos parâmetros coesivos nas previsões numéricas. Como resultado deste trabalho, foram estimadas experimentalmente as leis coesivas de cada adesivo pelo método direto, e numericamente validadas, para posterior previsão de resistência em juntas adesivas. Em conjunto com a caraterização à tração destes adesivos, é possível a previsão da rotura em modo-misto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enterococci are increasingly responsible for nosocomial infections worldwide. This study was undertaken to compare the identification and susceptibility profile using an automated MicrosScan system, PCR-based assay and disk diffusion assay of Enterococcus spp. We evaluated 30 clinical isolates of Enterococcus spp. Isolates were identified by MicrosScan system and PCR-based assay. The detection of antibiotic resistance genes (vancomycin, gentamicin, tetracycline and erythromycin) was also determined by PCR. Antimicrobial susceptibilities to vancomycin (30 µg), gentamicin (120 µg), tetracycline (30 µg) and erythromycin (15 µg) were tested by the automated system and disk diffusion method, and were interpreted according to the criteria recommended in CLSI guidelines. Concerning Enterococcus identification the general agreement between data obtained by the PCR method and by the automatic system was 90.0% (27/30). For all isolates of E. faecium and E. faecalis we observed 100% agreement. Resistance frequencies were higher in E. faecium than E. faecalis. The resistance rates obtained were higher for erythromycin (86.7%), vancomycin (80.0%), tetracycline (43.35) and gentamicin (33.3%). The correlation between disk diffusion and automation revealed an agreement for the majority of the antibiotics with category agreement rates of > 80%. The PCR-based assay, the van(A) gene was detected in 100% of vancomycin resistant enterococci. This assay is simple to conduct and reliable in the identification of clinically relevant enterococci. The data obtained reinforced the need for an improvement of the automated system to identify some enterococci.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A necessidade de utilizar métodos de ligação que melhor satisfaçam as necessidades de projeto tem causado a crescente utilização das juntas adesivas, em detrimento dos métodos tradicionais tais como a soldadura, ligações aparafusadas e rebitadas. A sua utilização em diversas aplicações industriais justifica-se pela redução de peso, redução de concentrações de tensões, isolamento acústico e melhor resistência à corrosão. Contudo, também apresentam desvantagens, como a necessidade de preparação das juntas, a fraca resistência a esforços de arrancamento e a complexidade da previsão da sua resistência. As juntas híbridas são obtidas por combinação de uma técnica tradicional com uma ligação adesiva. As juntas híbridas adesivas-soldadas obtêm-se através da combinação da ligação adesiva com a ligação soldada, sendo a soldadura de resistência por pontos a técnica de soldadura mais usada no fabrico deste tipo de juntas. A sinergia entre ligação adesiva e soldadura por pontos oferece vantagens competitivas em relação às ligações adesivas, tais como superior resistência e rigidez, e maior resistência ao arrancamento e à fadiga. No presente trabalho é apresentado um estudo experimental e numérico de juntas T-peel soldadas, adesivas e híbridas (adesivas-soldadas) solicitadas ao arrancamento. Considerouse o adesivo frágil Araldite® AV138 e os adesivos dúcteis Araldite® 2015 e Sikaforce® 7752 e aderentes de aço (C45E). Foi realizada uma análise dos valores experimentais e efetuada uma comparação destes valores com os resultados obtidos pelo Método de Elementos Finitos (MEF) no software ABAQUS®, que incluiu uma análise de tensões na camada de adesivo e previsão do comportamento das juntas por MDC. Observou-se que, dos três adesivos em estudo, o adesivo Sikaforce® 7752 é o que apresenta o melhor desempenho na ligação de juntas T-peel. A boa concordância entre os resultados experimentais e numéricos permitiu validar a utilização de MDC para previsão da resistência de juntas T-peel adesivas e híbridas. Assim, o presente trabalho representa uma base para posterior aplicação no projeto deste tipo de ligação, com as vantagens decorrentes na redução do tempo de projeto e maior facilidade de otimização.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the development and application of a new PCR assay for the specific detection of pathogenic leptospires and its comparison with a previously reported PCR protocol. New primers were designed for PCR optimization and evaluation in artificially-infected paraffin-embedded tissues. PCR was then applied to post-mortem, paraffin-embedded samples, followed by amplicon sequencing. The PCR was more efficient than the reported protocol, allowing the amplification of expected DNA fragment from the artificially infected samples and from 44% of the post-mortem samples. The sequences of PCR amplicons from different patients showed >99% homology with pathogenic leptospires DNA sequences. The applicability of a highly sensitive and specific tool to screen histological specimens for the detection of pathogenic Leptospira spp. would facilitate a better assessment of the prevalence and epidemiology of leptospirosis, which constitutes a health problem in many countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Does carotid intima-media thickness (cIMT), a surrogate marker of cardiovascular events, have predictive incremental value over established risk factors for stable coronary artery disease (CAD)? Prospective study of 300 patients, with suspected stable CAD, admitted for an elective coronary angiography and carotid ultrasound. The CAD patients had a higher cIMT, which showed a modest predictive accuracy for CAD (area under the receiver-operating characteristic curve 0.638, 95% confidence interval 0.576-0.701, P < .001). The cIMT was an independent predictor of CAD, together with age, gender, and diabetes. C-statistic for CAD prediction by traditional risk factors was not significantly different from a model that included cIMT, carotid plaque presence, or both. However, in women, it was significantly increased by the addition of cIMT or carotid plaque presence. Although cIMT cannot be used as a sole indicator of CAD, it should be considered in the panel of investigations that is requested, particularly in women who are candidates for coronary angiography.