930 resultados para Power Flow Control, Radial Distribution System, Distributed Generator (DG)
Resumo:
We recover and develop some robotic systems concepts (on the light of present systems tools) that were originated for an intended Mars Rover in the sixties of the last century at the Instrumentation Laboratory of MIT, where one of the authors was involved. The basic concepts came from the specifications for a type of generalized robot inspired in the structure of the vertebrate nervous systems, where the decision system was based in the structure and function of the Reticular Formation (RF). The vertebrate RF is supposed to commit the whole organism to one among various modes of behavior, so taking the decisions about the present overall task. That is, it is a kind of control and command system. In this concepts updating, the basic idea is that the RF comprises a set of computing units such that each computing module receives information only from a reduced part of the overall, little processed sensory inputs. Each computing unit is capable of both general diagnostics about overall input situations and of specialized diagnostics according to the values of a concrete subset of the input lines. Slave systems to this command and control computer, there are the sensors, the representations of external environment, structures for modeling and planning and finally, the effectors acting in the external world.
Resumo:
We present simulation results on how power output-input characteristic Instability in Distributed FeedBack -DFB semiconductor laser diode SLA can be employed to implemented Boolean logic device. Two configurations of DFB Laser diode under external optical injection, either in the transmission or in the reflective mode of operation, is used to implement different Optical Logic Cells (OLCs), called the Q- and the P-Device OLCs. The external optical injection correspond to two inputs data plus a cw control signal that allows to choose the Boolean logic function to be implement. DFB laser diode parameters are choosing to obtain an output-input characteristic with the values desired. The desired values are mainly the on-off contrast and switching power, conforming shape of hysteretic cycle. Two DFB lasers in cascade, one working in transmission operation and the other one in reflective operation, allows designing an inputoutput characteristic based on the same respond of a self-electrooptic effect device is obtained. Input power for a bit'T' is 35 uW(70uW) and a bit "0" is zero for all the Boolean function to be execute. Device control signal range to choose the logic function is 0-140 uW (280 uW). Q-device (P-device)
Resumo:
Knowledge modeling tools are software tools that follow a modeling approach to help developers in building a knowledge-based system. The purpose of this article is to show the advantages of using this type of tools in the development of complex knowledge-based decision support systems. In order to do so, the article describes the development of a system called SAIDA in the domain of hydrology with the help of the KSM modeling tool. SAIDA operates on real-time receiving data recorded by sensors (rainfall, water levels, flows, etc.). It follows a multi-agent architecture to interpret the data, predict the future behavior and recommend control actions. The system includes an advanced knowledge based architecture with multiple symbolic representation. KSM was especially useful to design and implement the complex knowledge based architecture in an efficient way.
Resumo:
Electrical power systems are changing their traditional structure, which was based on a little number of large generating power plants placed at great distances from loads by new models that tend to split the big production nodes in many smaller ones. The set of small groups which are located close to consumers and provide safe and quality energy is called distributed generation (DG). The proximity of the sources to the loads reduces losses associated with transportation and increases overall system efficiency. DG also favors the inclusion of renewable energy sources in isolated electrical systems or remote microgrids, because they can be installed where the natural resource is located. In both cases, as weak grids unable to get help from other nearby networks, it is essential to ensure appropriate behavior of DG sources to guarantee power system safety and stability. The grid codes sets out the technical requirements to be fulfilled for the sources connected in these electrical networks. In technical literature it is rather easy to find and compare grid codes for interconnected electrical systems. However, the existing literature is incomplete and sparse regarding isolated electrical systems and this happens due to the difficulties inherent in the pursuit of codes. Some countries have developed their own legislation only for their island territory (as Spain or France), others apply the same set of rules as in mainland, another group of island countries have elaborated a complete grid code for all generating sources and some others lack specific regulation. This paper aims to make a complete review of the state of the art in grid codes applicable to isolated systems, setting the comparison between them and defining the guidelines predictably followed by the upcoming regulations in these particular systems.
Resumo:
En el presente proyecto se propone la definición e implementación de un subsistema de monitorización para un sistema de tiempo real distribuido. Este monitor supervisará el estado de todos los componentes software y hardware del sistema original, y permitirá el arranque y parada de cada componente individualmente o del subsistema completo. Constará de dos componentes básicos: un supervisor local para cada subsistema, y un supervisor central con interfaz gráfica. El supervisor local es un componente software asociado a cada subsistema que realizará las funciones de monitorización, arranque/parada de los componentes y envío de informes al supervisor central. Atenderá además a los comandos de arranque y parada provenientes del supervisor central. El supervisor central recibirá los informes de estado de cada uno de los supervisores locales y permitirá el arranque y parada de los subsistemas. Contará con un interfaz gráfico a modo de posición de control. El sistema será desarrollado íntegramente (salvo la posición gráfica) en ADA95, y podrá ejecutarse en cualquiera de las distribuciones Linux más extendidas. En el contexto de Ingeniería de Software, se seguirá un desarrollo en cascada, aportándose los requisitos, el diseño, la codificación y un plan de pruebas. Abstract In this project, the definition and implementation of a monitoring system is proposed for a previously defined real-time distributed system. This supervisory system will monitor the status of each subsystem and its software and hardware components. This new system will also be able to start and stop each individual component and start or stop the entire system. It will consist of two basic components: a local supervisor for each subsystem, and a central supervisor with a graphical unit interface (GUI). The local supervisor will be a software component attached to each original subsystem, which will perform functions such as components monitoring, start and stop the associated subsystem, and sending reports to the central supervisor. It also will attend the start and stop commands from the central supervisor. The central supervisor will receive status reports from each of the local supervisors and will allow starting and stopping the subsystems. It will offer a graphical interface to be used as a main control panel. The system will be developed in ADA 95 (except the graphical position), and should work on any of the most common Linux distributions. In the context of Software Engineering, the project will be developed following a waterfall life cycle. Reports on the stages of requirements, design, coding and testing plan shall be provided.
Resumo:
Una red inalámbrica de sensores (Wireless Sensor Network, WSN) constituye un sistema de comunicación de datos flexible utilizado como alternativa a las redes cableadas o como extensión de éstas. Una de las aplicaciones de estas redes es para su uso en sistemas de predicción y prevención de incendios en áreas naturales. Su implementación se basa en el despliegue de sensores inalámbricos, realizado en una zona de riesgo de incendio que puedan recolectar información tal como temperatura, humedad y presión. Desde una estación base (o nodo "sumidero"), se suministra la información de los sensores a un centro de monitorización y control de forma estructurada. En estos centros la información recibida puede ser analizada, procesada y visualizada en tiempo real. Desde este centro de control se puede controlar también la red WSN modificando el comportamiento de los sensores según el nivel de riesgo de incendio detectado. Este proyecto se basa en el diseño, desarrollo e implementación de un Sistema de Control y Visualización de Información sobre Riesgo de Incendio (SCVIRI), que implementa las funciones de los centros de monitorización y control. La implementación de este sistema, junto con el desarrollado, en paralelo, de otro proyecto denominado Sistema de Estimación de Riesgo de Incendio Utilizando una WSN (SERIUW) que implementa la emulación de la red WSN, conforman un sistema general de anticipación y seguimiento de Fuegos. Se han realizado pruebas de funcionalidad y eficacia, incluidas en la presente memoria del sistema general (ambos proyectos), en un entorno controlado simulado. Este sistema es una solución para la lucha contra los incendios forestales ya que predice y previene, de forma temprana, posibles incendios en las áreas naturales bajo supervisión. Ante un evento de incendio declarado este sistema es un poderoso instrumento de apoyo permitiendo, por un lado, generar alertas automáticas (con localización y gravedad de fuegos detectados) y por el otro, hacer un seguimiento del incendio con mapas en tiempo real (con su consecuente apoyo para la protección e información con las brigadas de bomberos en las zonas activas). ABSTRACT. A wireless sensor network (WSN) is a flexible data communication system used as an alternative to wired networks or as an extension of them. One possible application of these networks is related to fire prediction and prevention in natural areas. Its implementation is based on a deployment of wireless sensors, in an area with high or moderate fire risk, to collect information such as temperature, humidity, luminance and pressure. A base station (or "sink") sends the collected information to a monitoring and control center according to an agreed structured format. At this center, the information received can be analyzed, processed and displayed in real time by using monitoring systems. From this control center the WSN can also be controlled by changing the sensors behavior in consistence with the detected level of fire risk. The work carried out in this project consists on the design, development and implementation of a system named SCVIRI, which implements the functions of the aforementioned monitoring and control center. This system works in connection with other one, called SERIUW, which has been developed in a different project and implements the WSN in an emulated environment. These two systems working together make up a general system of anticipation and monitoring of fires. This document also includes the functionality and performance tests performed on the overall system in a controlled and simulated environment. The global system is a solution that makes it easier to predict and prevent possible fires in natural areas under supervision. This system can be a powerful tool since, before a fire event is declared, it generates automatic alerts (including location and severity information) and allows the real-time motorization of fire evolution and its graphical visualization on maps. This could be also very useful for providing fire brigades with support, protection and information in zones in which a fire is already active.
Resumo:
The proton–sucrose symporter mediates the key transport step in the resource distribution system that allows many plants to function as multicellular organisms. In the results reported here, we identify sucrose as a signaling molecule in a previously undescribed signal-transduction pathway that regulates the symporter. Sucrose symporter activity declined in plasma membrane vesicles isolated from leaves fed exogenous sucrose via the xylem transpiration stream. Symporter activity dropped to 35–50% of water controls when the leaves were fed 100 mM sucrose and to 20–25% of controls with 250 mM sucrose. In contrast, alanine symporter and glucose transporter activities did not change in response to sucrose treatments. Decreased sucrose symporter activity was detectable after 8 h and reached a maximum by 24 h. Kinetic analysis of transport activity showed a decrease in Vmax. RNA gel blot analysis revealed a decrease in symporter message levels, suggesting a drop in transcriptional activity or a decrease in mRNA stability. Control experiments showed that these responses were not the result of changing osmotic conditions. Equal molar concentrations of hexoses did not elicit the response, and mannoheptulose, a hexokinase inhibitor, did not block the sucrose effect. These data are consistent with a sucrose-specific response pathway that is not mediated by hexokinase as the sugar sensor. Sucrose-dependent changes in the sucrose symporter were reversible, suggesting this sucrose-sensing pathway can modulate transport activity as a function of changing sucrose concentrations in the leaf. These results demonstrate the existence of a signaling pathway that can control assimilate partitioning at the level of phloem translocation.
Resumo:
O problema de Planejamento da Expansão de Sistemas de Distribuição (PESD) visa determinar diretrizes para a expansão da rede considerando a crescente demanda dos consumidores. Nesse contexto, as empresas distribuidoras de energia elétrica têm o papel de propor ações no sistema de distribuição com o intuito de adequar o fornecimento da energia aos padrões exigidos pelos órgãos reguladores. Tradicionalmente considera-se apenas a minimização do custo global de investimento de planos de expansão, negligenciando-se questões de confiabilidade e robustez do sistema. Como consequência, os planos de expansão obtidos levam o sistema de distribuição a configurações que são vulneráveis a elevados cortes de carga na ocorrência de contingências na rede. Este trabalho busca a elaboração de uma metodologia para inserir questões de confiabilidade e risco ao problema PESD tradicional, com o intuito de escolher planos de expansão que maximizem a robustez da rede e, consequentemente, atenuar os danos causados pelas contingências no sistema. Formulou-se um modelo multiobjetivo do problema PESD em que se minimizam dois objetivos: o custo global (que incorpora custo de investimento, custo de manutenção, custo de operação e custo de produção de energia) e o risco de implantação de planos de expansão. Para ambos os objetivos, são formulados modelos lineares inteiros mistos que são resolvidos utilizando o solver CPLEX através do software GAMS. Para administrar a busca por soluções ótimas, optou-se por programar em linguagem C++ dois Algoritmos Evolutivos: Non-dominated Sorting Genetic Algorithm-2 (NSGA2) e Strength Pareto Evolutionary Algorithm-2 (SPEA2). Esses algoritmos mostraram-se eficazes nessa busca, o que foi constatado através de simulações do planejamento da expansão de dois sistemas testes adaptados da literatura. O conjunto de soluções encontradas nas simulações contém planos de expansão com diferentes níveis de custo global e de risco de implantação, destacando a diversidade das soluções propostas. Algumas dessas topologias são ilustradas para se evidenciar suas diferenças.
Resumo:
O estudo refere-se à verificação da admissibilidade e da conveniência da exclusão facultativa de acionista controlador em sociedade anônima. O tema não é propriamente novo no Brasil. Intenciona-se, no entanto, construir a hipótese a partir de fundamento legal diferente. A Lei 6.404/76 (LSA) apenas destina a exclusão para casos de acionista remisso (artigo 107, II), permanecendo silente com relação ao inadimplemento de deveres de colaboração e lealdade (em conjunto, deveres de cooperação). Nesse contexto, a doutrina e a jurisprudência brasileiras tendem a admitir a hipótese de exclusão em tais casos por aplicação do artigo 1.030 do Código Civil, destinado a regular a matéria no âmbito das sociedades simples. Para tanto, aproximam a companhia fechada das sociedades de pessoas a fim de justificar, dada a alegada omissão da lei especial a esse respeito, o tratamento por analogia. A partir do estudo sistemático da LSA, que compreende, entre outros, o entendimento do princípio da circulação de ações e da extensão dos deveres de boa-fé entre os sócios, pretende-se admitir a hipótese com base na própria lógica acionária, em razão da eventual relevância do relacionamento societário para a consecução do fim social. Em tais companhias, o adimplemento dos deveres de cooperação torna-se tão imprescindível quanto o adimplemento do dever de conferimento para o alcance do escopo comum. Em decorrência desse raciocínio, a exclusão torna-se admissível na ocorrência de inadimplemento de qualquer dever social que inviabilize, real ou potencialmente, o preenchimento do fim social. A identificação de eventual affectio societatis entre os acionistas, portanto, passa a ser irrelevante. Admitir a hipótese no que se refere a acionista controlador se revela ainda importante instrumento de limitação do exercício ilegítimo do poder de controle e não se confunde com a sanção de perdas e danos prevista na LSA por abuso de poder de controle. Por fim, será analisada a conveniência da exclusão do controlador, em razão de sua relevância pessoal para a consecução da atividade, a participação societária por ele detida e da possibilidade de dissolver-se parcialmente a sociedade, com a saída do acionista minoritário descontente.
Resumo:
O transformador de potência é um importante equipamento utilizado no sistema elétrico de potência, responsável por transmitir energia elétrica ou potência elétrica de um circuito a outro e transformar tensões e correntes de um circuito elétrico. O transformador de potência tem ampla aplicação, podendo ser utilizado em subestações de usinas de geração, transmissão e distribuição. Neste sentido, mudanças recentes ocorridas no sistema elétrico brasileiro, causadas principalmente pelo aumento considerável de carga e pelo desenvolvimento tecnológico tem proporcionado a fabricação de um transformador com a aplicação de alta tecnologia, aumentando a confiabilidade deste equipamento e, em paralelo, a redução do seu custo global. Tradicionalmente, os transformadores são fabricados com um sistema de isolação que associa isolantes sólidos e celulose, ambos, imersos em óleo mineral isolante, constituição esta que define um limite à temperatura operacional contínua. No entanto, ao se substituir este sistema de isolação formado por papel celulose e óleo mineral isolante por um sistema de isolação semi- híbrida - aplicação de papel NOMEX e óleo vegetal isolante, a capacidade de carga do transformador pode ser aumentada por suportar maiores temperaturas. Desta forma, o envelhecimento do sistema de isolação poderá ser em longo prazo, significativamente reduzido. Esta técnica de aumentar os limites térmicos do transformador pode eliminar, essencialmente, as restrições térmicas associadas à isolação celulósica, provendo uma solução econômica para aperfeiçoar o uso de transformadores de potência, aumentando a sua confiabilidade operacional. Adicionalmente, à aplicação de sensores de fibra óptica, em substituição aos sensores de imagem térmica no monitoramento das temperaturas internas do transformador, se apresentam como importante opção na definição do equacionamento do comportamento do transformador sob o ponto de vista térmico.
Resumo:
Clusters of galaxies are expected to be reservoirs of cosmic rays (CRs) that should produce diffuse γ-ray emission due to their hadronic interactions with the intra-cluster medium. The nearby Perseus cool-core cluster, identified as the most promising target to search for such an emission, has been observed with the MAGIC telescopes at very-high energies (VHE, E ≥ 100 GeV) for a total of 253 hr from 2009 to 2014. The active nuclei of NGC 1275, the central dominant galaxy of the cluster, and IC 310, lying at about 0.6º from the centre, have been detected as point-like VHE γ-ray emitters during the first phase of this campaign. We report an updated measurement of the NGC 1275 spectrum, which is described well by a power law with a photon index Γ = 3.6 ± 0.2_(stat) ± 0.2_(syst) between 90 GeV and 1200 GeV. We do not detect any diffuse γ-ray emission from the cluster and so set stringent constraints on its CR population. To bracket the uncertainties over the CR spatial and spectral distributions, we adopt different spatial templates and power-law spectral indexes α. For α = 2.2, the CR-to-thermal pressure within the cluster virial radius is constrained to be ≤ 1 − 2%, except if CRs can propagate out of the cluster core, generating a flatter radial distribution and releasing the CR-to-thermal pressure constraint to ≤ 20%. Assuming that the observed radio mini-halo of Perseus is generated by secondary electrons from CR hadronic interactions, we can derive lower limits on the central magnetic field, B_(0), that depend on the CR distribution. For α = 2.2, B_(0) ≥ 5 − 8 µG, which is below the ∼25 µG inferred from Faraday rotation measurements, whereas for α ≤ 2.1, the hadronic interpretation of the diffuse radio emission contrasts with our γ-ray flux upper limits independently of the magnetic field strength.
Resumo:
Federal Highway Administration, Washington, D.C.
Resumo:
Includes bibliographical references and index.
Resumo:
Mode of access: Internet.
Resumo:
"The Illinois Department of Natural Resources/Office of Water Resources(IDNR/OWR) is cooperating with the Village of Garrett to construct a flood control project under the authority of the Flood Control Act of 1945, 615 ILCS 15 (2004 State Bar Edition)."