991 resultados para Plants - Effect of the moon on
Resumo:
The effect of the highly vasoactive peptide endothelin 1 (ET1) was tested on bovine retinal microvascular pericytes propagated in vitro. Specific binding of 125I-ET1 to retinal pericytes was documented by autoradiography. ET1 caused contraction of pericytes at a concentration of 0.1 nM which was accompanied by increases in inositol phosphates. Exposure of pericytes to 10 nM ET1 resulted in the aggregation and realignment of muscle-specific actins into bundles which were oriented parallel to the long axis of the cell, and ET1 was also mitogenic to pericytes in the presence of low levels of fetal calf serum. These observations suggest that ET1 may play an important role in endothelial cell-pericyte interactions within the microvasculature of the retina and that it may be involved in the autoregulation of retinal blood flow.
Resumo:
A study has been carried out to investigate whether the action of triclabendazole (TCBZ) against Fasciola hepatica is altered by the inhibition of P-glycoprotein (Pgp)-linked drug efflux pumps. The Sligo TCBZ-resistant and Cullompton TCBZ-susceptible fluke isolates were used for these experiments and the Pgp inhibitor selected was R(+)-verapamil [R-VPL]. In the first experiment, flukes were initially incubated for 2 h in R-VPL (100 µM), then incubated for a further 22 h in R-VPL+triclabendazole sulphoxide (TCBZ.SO) (50 µg/ml, or 0.1327 µM). For controls, flukes were incubated for 24 h in R-VPL and TCBZ.SO on their own. In a second experiment, flukes were removed from the incubation media following cessation of movement. In the third experiment, Sligo flukes were incubated in lower concentrations of R-VPL (10 µM) and TCBZ.SO (15 µg/ml, or 0.0398 µM). Morphological changes resulting from drug treatment and following Pgp inhibition were assessed by means of scanning electron microscopy. Incubation in R-VPL alone had minimal effect on either isolate. After treatment with TCBZ.SO alone, there was greater surface disruption to the Cullompton than Sligo isolate. However, combined treatment of R-VPL+TCBZ.SO led to more severe surface changes to the Sligo isolate than with TCBZ.SO on its own; this potentiation of drug activity was not seen with the Cullompton isolate. The phenomenon was evident at both concentrations of TCBZ.SO. Inclusion of R-VPL in the incubation medium also reduced the time taken for the flukes to become inactive; again, this effect was more distinct with the Sligo isolate. The results of this study support the concept of altered drug efflux in TCBZ-resistant flukes and indicate that drug transporters may play a role in the development of drug resistance.
Resumo:
The effect of preparation design and the physical properties of the interface lute on the restored machined ceramic crown-tooth complex are poorly understood. The aim of this work was to determine, by means of three-dimensional finite element analysis (3D FEA) the effect of the tooth preparation design and the elastic modulus of the cement on the stress state of the cemented machined ceramic crown-tooth complex. The three-dimensional structure of human premolar teeth, restored with adhesively cemented machined ceramic crowns, was digitized with a micro-CT scanner. An accurate, high resolution, digital replica model of a restored tooth was created. Two preparation designs, with different occlusal morphologies, were modeled with cements of 3 different elastic moduli. Interactive medical image processing software (mimics and professional CAD modeling software) was used to create sophisticated digital models that included the supporting structures; periodontal ligament and alveolar bone. The generated models were imported into an FEA software program (hypermesh version 10.0, Altair Engineering Inc.) with all degrees of freedom constrained at the outer surface of the supporting cortical bone of the crown-tooth complex. Five different elastic moduli values were given to the adhesive cement interface 1.8 GPa, 4 GPa, 8 GPa, 18.3 GPa and 40 GPa; the four lower values are representative of currently used cementing lutes and 40 GPa is set as an extreme high value. The stress distribution under simulated applied loads was determined. The preparation design demonstrated an effect on the stress state of the restored tooth system. The cement elastic modulus affected the stress state in the cement and dentin structures but not in the crown, the pulp, the periodontal ligament or the cancellous and cortical bone. The results of this study suggest that both the choice of the preparation design and the cement elastic modulus can affect the stress state within the restored crown-tooth complex.
Resumo:
A wide variety of processes make use of plain orifice nozzles. Fuel injectors for internal combustion engines incorporate these nozzles to generate finely atomized sprays. Processes such as jet cutting, jet cleaning, and hydroentanglement, on the other hand, use similar nozzles, but require coherent jets. The spray or jet characteristics depend on the stability of the flow emerging from the orifice. This problem has been extensively researched for nozzles with diameters above 300 μm. Much less is known about the characteristics of jets produced by nozzles with smaller diameters, where viscous effects and small geometric variations due to manufacturing tolerances are likely to play an increasing role. Results are presented of a wide-ranging investigation of geometry effects on the flow parameters and jet characteristics of nozzles with diameters between 120 and 170 μm. Nozzles with circular cross-section and conical, cone-capillary and capillary axial designs were investigated. For conical and cone-capillary nozzles, the effect of cone angle and effects due to interactions between adjacent nozzles in the multi-hole cone-capillary nozzles were studied. For capillary nozzles, the effects of diameter variations and inlet edge roundness for capillary nozzles were considered. Furthermore, the effect of varying the aspect ratio (ratio of major and minor axes) of elliptical nozzles was studied. Flowrate and jet impact force measurements were carried out to determine the discharge coefficient C, velocity coefficient C, and contraction coefficient C of the nozzles for supply pressures between 3 and 12 MPa. Visualizations of the jet flow were carried out in the vicinity of the nozzle exit in order to identify near-nozzle flow regimes and to study jet coherence. The relationship between nozzle geometry, discharge characteristics, and jet coherence is examined. © IMechE 2006.
Resumo:
Cone-capillary nozzles with varying cone angles from 10° to 120° and a capillary diameter of 120μ are experimentally investigated for their application in the hydroentanglement process. Cone-up and cone-down configurations in a range of water pressures of 30-120 bar are tested. The effects of the cone angle on flow parameters such as discharge and velocity coefficients and intact length are studied. Flow visualization techniques are used to recognize the flow regimes and characteristics and to inspect and compare the intact length and appearance of the jets. Cone-down nozzles with more consistent flow properties, lower discharges, and higher velocity coefficients are more suitable for the hydroentanglement process. Single-cone nozzles without capillaries and with varying cone angles are also tested. The flow properties of the jets from the single-cone nozzles are compared with the cone-capillary nozzles of the same cone angle to study the effect of the capillary section. The effect of the interaction of adjacent nozzles on the flow from multi-hole nozzles is studied, and the characteristics of the jets from the multi-hole nozzles are compared with the single-hole nozzles.
Resumo:
The power output from a wave energy converter is typically predicted using experimental and/or numerical modelling techniques. In order to yield meaningful results the relevant characteristics of the device, together with those of the wave climate must be modelled with sufficient accuracy.
The wave climate is commonly described using a scatter table of sea states defined according to parameters related to wave height and period. These sea states are traditionally modelled with the spectral distribution of energy defined according to some empirical formulation. Since the response of most wave energy converters vary at different frequencies of excitation, their performance in a particular sea state may be expected to depend on the choice of spectral shape employed rather than simply the spectral parameters. Estimates of energy production may therefore be affected if the spectral distribution of wave energy at the deployment site is not well modelled. Furthermore, validation of the model may be affected by differences between the observed full scale spectral energy distribution and the spectrum used to model it.
This paper investigates the sensitivity of the performance of a bottom hinged flap type wave energy converter to the spectral energy distribution of the incident waves. This is investigated experimentally using a 1:20 scale model of Aquamarine Power’s Oyster wave energy converter, a bottom hinged flap type device situated at the European Marine Energy Centre (EMEC) in approximately 13m water depth. The performance of the model is tested in sea states defined according to the same wave height and period parameters but adhering to different spectral energy distributions.
The results of these tests show that power capture is reduced with increasing spectral bandwidth. This result is explored with consideration of the spectral response of the device in irregular wave conditions. The implications of this result are discussed in the context of validation of the model against particular prototype data sets and estimation of annual energy production.
Resumo:
The objectives of this study were to investigate the effect of laser-induced surface features on the morphology, attachment and viability of mesenchymal stem cells (MSCs) at different periods of time, and to evaluate the biocompatibility of different zones: laser-melted zone (MZ), heat-affected zone (HAZ) and base metal (BM) in laser-treated NiTi alloy. The surface morphology and composition were studied by scanning electron microscope (SEM) and X-ray photoemission spectroscopy (XPS), respectively. The cell morphology was examined by SEM while the cell counting and viability measurements were done by haemocytometer and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) colorimetric assay. The results indicated that the laser-induced surface features, such as surface roughening, presence of anisotropic dendritic pattern and complete surface Ni oxidation were beneficial to improve the biocompatibility of NiTi as evidenced by the highest cell attachment (4 days of culture) and viability (7 days of culture) found in the MZ. The biocompatibility of the MZ was the best, followed by the BM with the HAZ being the worst. The defective and porous oxide layer as well as the coarse grained structure might attribute to the inferior cell attachment (4 days of culture) and viability (7 days of culture) on the HAZ compared with the BM which has similar surface morphology.
Resumo:
We argue that the partition of ethnic groups following the Scramble for Africa does not itself matter for development in Africa. It matters only when the partitioned groups are relatively small because small groups lack political representation which may promote ethnic mobilization and foster support for informal (rather than formal) institutions which then may a ect development. Furthermore, the analysis of data from the Afrobarometer shows that the persistence of informal/tribal institutions related to property rights and the rule of law is one of the possible channels through which the size of the partitioned group a ects development.