986 resultados para Performance appraisal
Resumo:
Performance Tables 1999-2000 (20/12/00)
Resumo:
Performance Tables for 1998-1999 (18/11/99)
Resumo:
The Charter for Patients and Clients
Resumo:
The Charter for Patients and Clients
Resumo:
In 2009, the Sheffield Alcohol Research Group (SARG) at Sheffield University developed the Sheffield Alcohol Policy Model version 2.0 (SAPM) to appraise the potential impact of alcohol policies, including different levels of MUP, for the population of England. In 2013, SARG were commissioned by the DHSSPS and the Department for Social Development to adapt the Sheffield Model to NI in order to appraise the potential impact of a range of alcohol pricing policies. The present report represents the results of this work. Estimates from the Northern Ireland (NI) adaptation of the Sheffield Alcohol Policy Model - version 3 - (SAPM3) suggest: 1. Minimum Unit Pricing (MUP) policies would be effective in reducing alcohol consumption, alcohol related harms (including alcohol-related deaths, hospitalisations, crimes and workplace absences) and the costs associated with those harms. 2. A ban on below-cost selling (implemented as a ban on selling alcohol for below the cost of duty plus the VAT payable on that duty) would have a negligible impact on alcohol consumption or related harms. 3. A ban on price-based promotions in the off-trade, either alone or in tandem with an MUP policy would be effective in reducing alcohol consumption, related harms and associated costs. 4. MUP and promotion ban policies would only have a small impact on moderate drinkers at all levels of income. Somewhat larger impacts would be experienced by increasing risk drinkers, with the most substantial effects being experienced by high risk drinkers. 5. MUP and promotion ban policies would have larger impacts on those in poverty, particularly high risk drinkers, than those not in poverty. However, those in poverty also experience larger relative gains in health and are estimated to marginally reduce their spending due to their reduced drinking under the majority of policies åÊ
Resumo:
Performance-Related Awards: Health Boards Scheme This progress report to September 2003 on the performance-related awards scheme for senior health board management has been prepared by the Committee for Performance Awards for the Health Board Scheme, in line with the recommendation in Report No. 38 of the Review Body for Higher Remuneration in the Public Sector, to contribute to the Review Bodyâ?Ts consideration at its next general review (para 13.4). Click here to download PDF 93kb
Resumo:
Click here to download PDF
Resumo:
Alternative, non-microscopic methods for the diagnosis of malaria have recently become available. Among these, rapid dipstick methods stand out. One such test, OptiMAL®, is based on the immunochromatographic detection of Plasmodium lactate dehydrogenase (pLDH) and has the capacity to detect and distinguish infections caused by P. falciparum and Plasmodium sp. This capacity is particularly important in countries where different species of Plasmodium co-exist. In this study we evaluated the performance of OptiMAL® in an urban referral center for malaria diagnosis. Two sets of patients were included: one (n = 112) having predetermined infections with P. falciparum or P. vivax and individuals with negative blood smears; and another consisting of all eligible consecutive patients (n = 80) consulting for diagnosis at the referral center during one month. The overall diagnostic efficiency of OptiMAL® for both sets of patients was 96.9%. Efficiency was higher for P. vivax (98.1%) than for P. falciparum (94.9%). These results corroborate the diagnostic utility of OptiMAL® in settings where P. vivax and P. falciparum co-exist and support its implementation where microscopic diagnosis is unavailable and in circumstances that exceed the capacity of the local microscopic diagnosis facility.
Resumo:
AbstractPerforming publicly has become increasingly important in a variety of professions. This condition is associated with performance anxiety in almost all performers. Whereas some performers successfully cope with this anxiety, for others it represents a major problem and even threatens their career. Musicians and especially music students were shown to be particularly affected by performance anxiety.Therefore, the goal of this PhD thesis was to gain a better understanding of performance anxiety in university music students. More precisely, the first part of this thesis aimed at increasing knowledge on the occurrence, the experience, and the management of performance anxiety (Article 1). The second part aimed at investigating the hypothesis that there is an underlying hyperventilation problem in musicians with a high level of anxiety before a performance. This hypothesis was addressed in two ways: firstly, by investigating the association between the negative affective dimension of music performance anxiety (MPA) and self-perceived physiological symptoms that are known to co-occur with hyperventilation (Article 2) and secondly, by analyzing this association on the physiological level before a private (audience-free) and a public performance (Article 3). Article 4 places some key variables of Article 3 in a larger context by jointly analyzing the phases before, during, and after performing.The main results of the self-report data show (a) that stage fright is experienced as a problem by one-third of the surveyed students, (b) that the students express a considerable need for more help to better cope with it, and (c) that there is a positive association between negative feelings of MPA and the self-reported hyperventilation complaints before performing. This latter finding was confirmed on the physiological level in a tendency of particularly high performance-anxious musicians to hyperventilate. Furthermore, the psycho-physiological activation increased from a private to a public performance, and was higher during the performances than before or after them. The physiological activation was mainly independent of the MPA score. Finally, there was a low response coherence between the actual physiological activation and the self-reports on the instantaneous anxiety, tension, and perceived physiological activation.Given the high proportion of music students who consider stage fright as a problem and given the need for more help to better cope with it, a better understanding of this phenomenon and its inclusion in the educational process is fundamental to prevent future occupational problems. On the physiological level, breathing exercises might be a good means to decrease - but also to increase - the arousal associated with a public performance in order to meet an optimal level of arousal needed for a good performance.
Resumo:
Appraisal consultation document - Cetuximab for the treatment of recurrent and/or metastatic squamous cell cancer of the head and neck.To take part in the 'Cetuximab for the treatment of metastatic and/or recurrent squamous cell carcinoma of the head and neck: appraisal consultation'
Resumo:
Whereas during the last few years handling of the transcutaneous PO2 (tcPO2) and PCO2 (tcPCO2) sensor has been simplified, the high electrode temperature and the short application time remain major drawbacks. In order to determine whether the application of a topical metabolic inhibitor allows reliable measurement at a sensor temperature of 42 degrees C for a period of up to 12 h, we performed a prospective, open, nonrandomized study in a sequential sample of 20 critically ill neonates. A total of 120 comparisons (six repeated measurements per patient) between arterial and transcutaneous values were obtained. Transcutaneous values were measured with a control sensor at 44 degrees C (conventional contact medium, average application time 3 h) and a test sensor at 42 degrees C (Eugenol solution, average application time 8 h). Comparison of tcPO2 and PaO2 at 42 degrees C (Eugenol solution) showed a mean difference of +0.16 kPa (range +1.60 to -2.00 kPa), limits of agreement +1.88 and -1.56 kPa. Comparison of tcPO2 and PaO2 at 44 degrees C (control sensor) revealed a mean difference of +0.02 kPa (range +2.60 to -1.90 kPa), limits of agreement +2.12 and -2.08 kPa. Comparison of tcPCO2 and PaCO2 at 42 degrees C (Eugenol solution) showed a mean difference of +0.91 (range +2.30 to +0.10 kPa), limits of agreement +2.24 and -0.42 kPa. Comparison of tcPCO2 and PaCO2 at 44 degrees C (control sensor) revealed a mean difference of +0.63 kPa (range 1.50 to -0.30 kPa), limits of agreement +1.73 and -0.47 kPa. CONCLUSION: Our results show that the use of an Eugenol solution allows reliable measurement of tcPO2 at a heating temperature of 42 degrees C; the application time can be prolongued up to a maximum of 12 h without aggravating the skin lesions. The performance of the tcPCO2 monitor was slightly worse at 42 degrees C than at 44 degrees C suggesting that for the Eugenol solution the metabolic offset should be corrected.