906 resultados para Orthodontic extrusion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To verify the cleaning of the apical foramen and apical extrusion of dentin chips in single-rooted teeth instrumented with two techniques, one of which including the apical patency procedure. Method: Thirty teeth were internally stained with Indian ink, divided in two groups, of which only group I was subjected to apical patency. The dentin chips extruded through the apical foramen were collected in a glass receptacle and quantified. The apical foramen region was divided in quadrants and analyzed with a stereomicroscope to verify the action of the instrument on the cemental canal walls. The teeth were scored 0 4 according to the number of clean walls (without Indian ink), 0 corresponding to no clean wall. Results: In group I, there was no dentin plug, but only 1 tooth was scored 4. In group II, 10 teeth presented dentin plug and all of them were scored 0. There was no statistically significant difference between groups I and II regarding the extruded dentin mass (Scheffé test; p<0.05). Conclusion: The use of the apical patency procedure in single-rooted teeth does not modify the amount of dentin chips extruded through the apical foramen, does not produce an adequate cleaning of the cemental canal walls, but remove the plug of dentin chips from the cemental canal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report our achievements in the elaboration and optical characterizations of low-losses suspended core optical fibers elaborated from As2S3 glass. For preforms elaboration, alternatively to other processes like the stack and draw or extrusion, we use a process based on mechanical drilling. The drawing of these drilled performs into fibers allows reaching a suspended core geometry, in which a 2 μm diameter core is linked to the fiber clad region by three supporting struts. The different fibers that have been drawn show losses close to 0.9 dB/m at 1.55 μm. The suspended core waveguide geometry has also an efficient influence on the chromatic dispersion and allows its management. Indeed, the zero dispersion wavelength, which is around 5 μm in the bulk glass, is calculated to be shifted towards around 2μm in our suspended core fibers. In order to qualify their nonlinearity we have pumped them at 1.995 μm with the help of a fibered ns source. We have observed a strong non linear response with evidence of spontaneous Raman scattering and strong spectral broadening. © 2011 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To analyze the effects of thermal cycling on the microtensile shear bond strength of a self-etching and a conventional pit and fissure sealants to dental enamel. Material and Method: Twenty-four healthy human molars extracted for orthodontic reasons, were sectioned in the mesio-distal direction and divided into two groups (n=24) according to the sealant to be applied: GI - conventional sealant Climpro (3M/ESPE) and GII - self-etching sealant Enamel Loc (Premier Dental). The sealants were applied on flattened enamel in matrixes 1 mm in diameter, in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37°C for 24 hours. After this, half the samples of both groups were submitted to 500 thermal cycles in 30s baths at temperatures between 5 and 55°C. Forty-eight hours after the samples were made, the microtensile shear test was performed in an Instron 4411 test machine, with a stainless steel wire with a cylindrical cross section of 0.2mm in diameter at a constant speed of 0.5mm/s. The bond strength values were submitted to ANOVA for 2 factors and the fracture patterns were examined under an optical microscope at 65X magnification. Results: Thermal cycling did not influence the bond strength of the two sealants. The conventional sealant Climpro presented a statistically higher microtensile shear bond strength (11.72MPa, 11.34MPa with and without cycling, respectively) than the self-etching sealant Enamel Loc (5.92MPa, 5.02MPa with and without cycling, respectively). Fracture pattern analysis showed the occurrence of 100% of adhesive failures for Enamel Loc, while the conventional sealant Climpro presented 95% of adhesive failures and 5% of mixed failures. Conclusion: The conventional sealant presented higher microtensile shear bond strength to dental enamel in comparison with the self-etching sealant. Thermal cycling did not affect the bond strength of the sealants used in this study. © 2011 Nova Science Publishers, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: An appropriate selection of instruments is essential to perform a correct debonding technique, by properly removing orthodontic brackets and the remaining resin. Objective: The aim of this study was to evaluate three methods of remaining resin removal on enamel surface after bracket debonding, by means of Scanning Electron Microscopy (SEM). Methods: Eighteen bovine incisors were selected and divided into three groups (A, B and C) of six teeth each. Before bracket bonding, epoxy resin casts were obtained by impression of the teeth with addition silicon, in order to register baseline enamel characteristics and representing the control group. The methods for remaining resin removal were: Group A - gross and medium granulation Soflex discs; Group B - carbide bur in low-speed; Group C - carbide bur in high-speed. Soflex polishing system fine and ultrafine granulation discs were used for Group A, rubber tips for Groups B and C, and polishing paste for all groups. After polishing, impression of teeth were taken and casts were analyzed by means of SEM. The baseline enamel characteristics (Control Group) were compared to the final aspect of enamel to determine the method that generated less enamel abrasion. Results and Conclusion: The remaining resin removal by carbide bur in low-rotation, and enamel polished with rubber tips followed by polishing paste produced the smaller damage to the enamel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A set of 12 samples of acid rock types Palmas (ATP) and Chapecó (ATC) was used to determine the chemical composition of plagioclase and pyroxene by electron microprobe, with the purpose to get information about the pressure and temperature of crystallization of these rocks. The results show that the pyroxene of ATP rocks (3,2 ± 1,2 kbar, max = 5,1 kbar and 1028 ± 38°C) were formed under pressure conditions higher than those ATC (1,8 ± 0,9 kbar, max = 3,4 kbar and 995 ± 26oC). However, the pressures obtained from plagioclase showed higher pressures for ATC (3.2 ± 1 kbar, max = 6,4 kbar and 1033 ± 12°C) than ATP (1,9 ± 1 kbar, max = 4,8 kbar and 1043 ± 5°C), suggesting that the crystallization of rocktype ATP began with the formation of pyroxene and plagioclase almost simultaneously at a depth of around 17 km while the ATC, began with the crystallization of plagioclase at a depth of about 21 km (assuming a gradient of 3,3 kbar/km). The geothermometry of plagioclase allow us to calculate the concentration of water from about 1 ± 0,3% H2O for both acid rock types. Additional calculations allow us to get the depth of water exsolution of magmatic liquid at 30m below the surface. Although the data are still preliminary and insufficient to model the extrusion of these rocks, they point out to an effusion mechanism of a partially fluidized magma by volatile, which would spread to large areas with small friction with the surface that would increased with the increase of viscosity caused by the loss of volatile and decreasing of temperature, developing coherent structures as lava flows.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work evaluated the effects of high moisture silage, extrusion and corn and sorghum drying with and without tannin, on the chemical composition and ruminal digestion of dry matter. The experimental design was completely randomized in 3x3 factorial scheme (kinds of grains: processing), for the chemical composition and degradability and three blocks (animals) through in situ method. It was verified significant difference between kinds of grains and processing in relation to the chemical composition, except for crude protein and mineral matter. The contents of etherextract in the three types of grains, were reduced significantly with the high moisture silage, extrusion and drying in relation to the humid material. For the contents of phenols, total and condensed tannin there was effect of hybrid, processing and interaction, and the most elevated contents were found in sorghum with tannin. Although grain composition has been similar, the interaction in ruminal ambient associated to the tannin, promoted differences in the dry matter degradability. It was concluded that sorghum without tannin may be ensiled or extruded, while the sorghum with tannin, must be extruded to improve the degradability and availability of nutrients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The present case report described the use of contact lens of thin porcelain veneers as a restorative therapy to solve anterior teeth disharmony. Background: Fragments of thin veneers are minimally invasive restorations with little or no dental preparation and present thickness ranging from 0.2 to 0.5 mm. They are used in case of diastema closure, small changes of teeth, color and restoration of teeth with small fractures. Case report: A 25-year-old man was admitted at a dental clinic complaining about the diastema presence on the upper anterior teeth. Patient was referred to an orthodontic treatment in order to provide better distribution of the diastemas and harmonious proportion of the teeth. Afterwards, contact lens of thin porcelain veneers were fabricated on the six upper anterior teeth. Conclusion: Based on the outcomes of this clinical report, we considered the use of fragments of thin veneers as a successful treatment option after 3 years of follow-up. Clinical significance: The fragments of thin veneers have been established to be an interesting alternative to esthetically restore the anterior teeth with minimal invasiveness. However, since it is a new treatment modality, longitudinal studies are necessary to understand the material's behavior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right eye followed by implantation of cones made from Bioglass® 45S5 (control group) and two types of bioactive glass-ceramic (Biosilicate®), a single- and a two-phase bioactive glass-ceramic implants into the scleral cavity. Postoperative reactions, animal behavior and socket conditions were monitored daily. Clinical exam, biochemical evaluations, and orbit computed tomographic scan were done at 7, 90, and 180 days post-procedure. After that, the animals were euthanized, and the orbital content was removed and prepared to light microscopy with morphometric evaluation and scanning electron microscopy examination. Statistical analysis was done by parametric and non-parametric analysis of variance, complemented by Dunn's and Tukey's tests (p<0.05). Results: All animals did not develop systemic toxicity throughout the experimental period and also did not have orbit infection, implant migration or extrusion. Morphological analysis demonstrated pseudocapsule around all implants. Bioglass® and single-phase Biosilicate® implants induced less inflammation and pseudocapsule formation than two-phase Biosilicate® cones. Seven days post-procedure, the inflammatory reaction was intense and gradually decreased throughout the experiment. Tissue reaction was least intense in animals receiving Bioglass® implants. Conclusions: We observe discrete differences among the studied materials, with best responses obtained with use of Bioglass® 45S5 and single-phase Biosilicate®. The authors agree these implants might be useful in the management of the anophthalmic socket. © 2012 Informa Healthcare USA, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article presents a case report of autogenous tooth transplantation to the site of the fissure, in addition to bone augmentation with graft of autogenous bone harvested from the iliac crest, performed in a cleft palate patient, who had insufficient bone volume. A non-syndromic 10-year-old girl, with a unilateral cleft lip and palate, incisal transforamen fissures, agenesis of the maxillary left central incisor and both maxillary lateral incisors, was treated with autogenous bone graft in the cleft area. The orthodontic treatment plan was to replace the missing lateral incisors with the maxillary canines and to extract the mandibular first premolars. One of the mandibular premolars was extracted from its site with 2/3 of its root formation completed and transplanted to the maxillary left central incisor area. After orthodontic treatment, the anatomic crowns were characterized with composite resin. Autogenous tooth transplantation can be performed in the area of the fissure in young cleft palate patients, by performing bone graft augmentation before transplantation of the tooth, to gain sufficient recipient alveolar bone volume. A multidisciplinary approach is mandatory for the success of this clinical procedure, especially in cleft palate patients. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated whether periodontal ligament (PL) thickness varied with root size and examined the possible influence of this variation on orthodontic mechanics. Measurements were taken of the maxillary left first molar in 54 male Wistar rats. Mean mesial and distal PL thicknesses were compared between the intermediate buccal and mesiobuccal roots using paired Student's t-tests with a 5% significance level. Mean values differed significantly between roots (p < 2.2 × 10-16). PL thickness in rats is directly proportional to root dimensions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interpretation of the set of radiographs taken during the follow-up period after tooth replantation might pose several difficulties, especially the inability to adequately reproduce the projection geometry of the exposures. This article describes a method for the geometric standardization of intraoral radiographs using a custom-made apparatus comprising a film-holder attached to an occlusal splint for the long-term follow up of dentoalveolar trauma. The method was applied in a patient who suffered an avulsion of the maxillary central incisors and had the teeth replanted after 4 h in saline storage. Endodontic treatment started 7 days after the trauma with changes of a calcium hydroxide intracanal medication every 15 days in the first 2 months and thereafter at 30-day intervals for 8 months. Root canal filling was carried out after this period. The radiographic exposures taken at the follow-up visits were standardized to identify the possible alterations during the repair process, such as root resorptions. A maxillary arch impression was made with alginate, and the model was cast in stone for fabrication of an acetate occlusal splint. The custom-made apparatus used for standardization of the radiographic exposures was fabricated by fixing a Rinn X-C-P film-holder and a 5-mm-long piece of 0.7-mm orthodontic wire to the occlusal splint with autopolymerized acrylic resin. Radiographs were taken at 4-month intervals, starting 10 months after replantation up to 76 months. The images were digitized and analysed using the Digora system. The length of the central incisors was determined to verify the reproduction of the projection geometry of the exposures and the orthodontic wire served to assess accuracy during length estimations in the radiographs. The method described in this article for geometric standardization of intraoral radiographs provided a consistent reproduction of the geometric exposure parameters, being indicated for use in the radiographic follow up of cases of dentoalveolar trauma. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of exogenous enzymes supplementation on kibble diets for dogs formulated with soybean meal (SBM) as a substitute for poultry by-product meal (PM) was investigated on nutrient digestibility, fermentation products formation, post-prandial urea response and selected faecal bacteria counts. Two kibble diets with similar compositions were used in two trials: PM-based diet (28.9% of PM; soybean hulls as a fibre source) and SBM-based diet (29.9% of SBM). In experiment 1, the SBM diet was divided into three diets: SBM-0, without enzyme addition; SBM-1, covered after extrusion with 7500U protease/kg and 45U cellulase/kg; and SBM-2, covered with 15000U protease/kg and 90U cellulase/kg. In experiment 2, the SBM diet was divided into three diets: SBM-0; SBM-1, covered with 140U protease/kg; 8U cellulase/kg, 800U pectinase/kg, 60U phytase/kg, 40U betaglucanase/kg and 20U xylanase/kg; and SMB-2, covered with 700U protease/kg, 40U cellulase/kg, 4000U pectinase/kg, 300U phytase/kg, 200U betaglucanase/kg and 100U xylanase/kg. Each experiment followed a block design with six dogs per diet. Data were submitted to analysis of variance and means compared by orthogonal and polynomial contrasts (p<0.05). In both experiments, nutrients and energy digestibility did not differ between diets (p>0.05). SBM consumption resulted in increased faecal moisture and production (p<0.05), without effect on faecal score. Higher concentration of propionate, acetate and lactate, and lower ammonia and pH were found in the faeces of dogs fed SBM (p<0.05). Higher post-prandial urea was verified in dogs fed SBM (p<0.05). In experiment 2, the addition of enzymes increased faecal concentration of propionate, acetate and total short-chain fatty acid (p<0.05) and tended to reduce post-prandial urea concentration (p=0.06). Although with similar digestibility, SBM shows a worse utilization of absorbed amino acids than the PM. Soybean oligosaccharides can beneficially change gut fermentation product formation. Enzymes can increase the gut fermentation activity and improve the SBM proteic value. © 2013 Blackwell Verlag GmbH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, there is an interest in technologies that favour the use of coproducts for animal nutrition. The effect of adding two enzyme mixtures in diets for dogs formulated with wheat bran (WB) was evaluated. Two foods with similar compositions were formulated: negative control (NC; without WB) and test diet (25% of WB). The test diet was divided into four treatments: without enzyme (positive control), enzyme mixture 1 (ENZ1; added before extrusion β-glucanase, xylanase, cellulase, glucoamylase, phytase); enzyme mixture 2 (ENZ2; added before extrusion the ENZ1 more α-amylase); enzyme mixture 2 added after the extrusion (ENZ2ex). ENZ1 and ENZ2 were used to evaluate the enzyme effect on extruder pre-conditioner (processing additive) and ENZ2ex to evaluate the effect of enzyme supplementation for the animal. Digestibility was measured through total collection of faeces and urine. The experiment followed a randomized block design with five treatments (diets) and six dogs per diet, totalling 30 dogs (7.0 ± 1.2 years old and 11.0 ± 2.2 kg of body weight). Data were submitted to analysis of variance and means compared by Tukey's test and orthogonal contrasts (p < 0.05). Reducing sugars showed an important reduction after extrusion, suggesting the formation of carbohydrate complexes. The apparent total tract digestibility (ATTD) of dry matter, organic matter, crude protein, acid-hydrolysed fat and energy was higher in NC than in diets with WB (p < 0.001), without effects of enzyme additions. WB diets resulted in higher faecal production and concentration of short-chain fatty acids (SCFA) and reduced pH and ammonia concentration (p < 0.01), with no effect of enzyme addition. The enzyme addition did not result in improved digestibility of a diet high in non-starch polysaccharides; however, only ATTD was measured and nutrient fermentation in the large intestine may have interfered with the results obtained. WB modified fermentation product formation in the colon of dogs. © 2013 Blackwell Verlag GmbH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Primary failure of tooth eruption (PFE) is a rare autosomal-dominant disease characterized by severe lateral open bite as a consequence of incomplete eruption of posterior teeth. Heterozygous mutations in the parathyroid hormone 1 receptor (PTH1R) gene have been shown to cause PFE likely due to protein haploinsufficiency. To further expand on the mutational spectrum of PFE-associated mutations, we report here on the sequencing results of the PTH1R gene in 70 index PFE cases. Materials and methods: Sanger sequencing of the PTH1R coding exons and their immediate flanking intronic sequences was performed with DNA samples from 70 index PFE cases. Results: We identified a total of 30 unique variants, of which 12 were classified as pathogenic based on their deleterious consequences on PTH1R protein while 16 changes were characterized as unclassified variants with as yet unknown effects on disease pathology. The remaining two variants represent common polymorphisms. Conclusions: Our data significantly increase the number of presently known unique PFE-causing PTH1R mutations and provide a series of variants with unclear pathogenicity which will require further in vitro assaying to determine their effects on protein structure and function. Clinical relevance: Management of PTH1R-associated PFE is problematic, in particular when teeth are exposed to orthodontic force. Therefore, upon clinical suspicion of PFE, molecular DNA testing is indicated to support decision making for further treatment options. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To evaluate the surgical outcomes of patients with complete unilateral cleft lip and palate (CUCLP) operated on by a single surgeon of the cleft reference center of the Lauro Wanderley University Hospital at the Federal University of Paraiba. Methods: Forty-four individuals' dental casts diagnosed with CUCLP, born between 1995 and 2002, mean age of 11 years, were evaluated by three calibrated orthodontic specialists and scored by the Great Ormond Street, London and Oslo (GOSLON) yardstick on two occasions. The scores were compared with those observed in other centers around the world. The Kappa test was applied to evaluate the intra- and inter-examiner agreement. Descriptive statistics was applied for the GOSLON yardsticks core. Results: The mean GOSLON score was 2.75. For the GOSLON yardstick, 43.2 % of the sample presented scores 1 and 2, 31.8 % had score 3, and 25 % were with scores 4 and 5. There was very good intra- and inter-examiner Kappa agreement in the application of the GOSLON yardstick. Conclusions: The data suggest favorable outcomes, with 75 % of cases with no need of orthognathic surgery. The Kappa values confirmed the high reproducibility of the GOSLON yardstick. © 2013 Springer-Verlag Berlin Heidelberg.