991 resultados para Orthodontic appliance
Resumo:
The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
Resumo:
The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the mandibular anterior teeth after orthodontic treatment.
Resumo:
Our aim was to quantitatively determine the bisphenol-A (BPA) released from a light-cured orthodontic adhesive used to bond lingual fixed retainers.
Resumo:
Background: The clinical use of an enamel matrix derivative (EMD) has been shown to promote formation of new cementum, periodontal ligament (PDL), and bone and to significantly enhance the clinical outcomes after regenerative periodontal surgery. It is currently unknown to what extent the bleeding during periodontal surgery may compete with EMD adsorption to root surfaces. The aim of this study is to evaluate the effect of blood interactions on EMD adsorption to root surfaces mimicking various clinical settings and to test their ability to influence human PDL cell attachment and proliferation. Methods: Teeth extracted for orthodontic reasons were subjected to ex vivo scaling and root planing and treated with 24% EDTA, EMD, and/or human blood in six clinically related settings to determine the ability of EMD to adsorb to root surfaces. Surfaces were analyzed for protein adsorption via scanning electron microscopy and immunohistochemical staining with an anti-EMD antibody. Primary human PDL cells were seeded on root surfaces and quantified for cell attachment and cell proliferation. Results: Plasma proteins from blood samples altered the ability of EMD to adsorb to root surfaces on human teeth. Samples coated with EMD lacking blood demonstrated a consistent even layer of EMD adsorption to the root surface. In vitro experiments with PDL cells demonstrated improved cell attachment and proliferation in all samples coated with EMD (irrespective of EDTA) when compared to samples containing human blood. Conclusion: Based on these findings, it is advised to minimize blood interactions during periodontal surgeries to allow better adsorption of EMD to root surfaces.
Resumo:
Bonding a flexible spiral wire retainer to the lingual surfaces of all 6 anterior mandibular teeth is a commonly used type of retention. Complications are rare but can be serious enough to produce biologic damage. This article presents a serious complication of a lingual flexible spiral wire retainer. Four years after the orthodontic treatment, a 20-year-old man sought treatment for a broken flexible spiral wire retainer. The clinical examination showed about 35° of buccal root torque of that tooth. A cone-beam computed tomography image showed that the root and the apex of the tooth were almost completely out of the bone on its buccal side. Surprisingly, the tooth's vitality was preserved. The tooth was moved back, nearly to its original position; clinically, only a gingival recession remained. Orthodontists and dentists should be aware of possible complications of bonded retainers. Patients should be clearly informed how to detect problems at an early stage.
Resumo:
Abstract Objectives: To assess the reporting quality of Cochrane and non-Cochrane systematic reviews (SR) in orthodontics and to compare the reporting quality (PRISMA score) with methodological quality (AMSTAR criteria). Materials and Methods: Systematic reviews (n = 109) published between January 2000 and July 2011 in five leading orthodontic journals were identified and included. The quality of reporting of the included reviews was assessed by two authors in accordance with the PRISMA guidelines. Each article was assigned a cumulative grade based on fulfillment of the applicable criteria, and an overall percentage score was assigned. Descriptive statistics and simple and multiple linear regression analyses were undertaken. Results: The mean overall PRISMA score was 64.1% (95% confidence interval [CI], 62%-65%). The quality of reporting was considerably better in reviews published in the Cochrane Database of Systematic Reviews (P < .001) than in non-Cochrane reviews. Both multivariable and univariable analysis indicated that journal of publication and number of authors was significantly associated with the PRISMA score. The association between AMSTAR score and modified PRISMA score was also found to be highly statistically significant. Conclusion: Compliance of orthodontic SRs published in orthodontic journals with PRISMA guidelines was deficient in several areas. The quality of reporting assessed using PRISMA guidelines was significantly better in orthodontic SRs published in the Cochrane Database of Systematic Reviews.
Resumo:
In this study, we aimed to investigate whether studies published in orthodontic journals and titled as randomized clinical trials are truly randomized clinical trials. A second objective was to explore the association of journal type and other publication characteristics on correct classification.
Resumo:
A case is presented of extensive alveolar bone grafting in a patient with bilateral cleft lip and palate and polyostotic fibrous dysplasia. The patient previously underwent bisphosphonate therapy. Because of an abnormal and often decreased bone turnover caused by the fibrous dysplasia and the bisphosphonate therapy, bone grafting in such a patient poses several potential difficulties. In addition, the histomorphometric analysis of the bone grafts showed markedly decreased bone turnover. However, alveolar bone grafting using the iliac crest was performed successfully. Sufficient occlusion was achieved by postoperative low-loading orthodontic treatment.
Resumo:
This study analyzes short- and long-term skeletal relapse after mandibular advancement surgery and determines its contributing factors. Thirty-two consecutive patients were treated for skeletal Class II malocclusion during the period between 1986 and 1989. They all had combined orthodontic and surgical treatment with BSSO and rigid fixation excluding other surgery. Of these, 15 patients (47%) were available for a long-term cephalography in 2000. The measurement was performed based on the serial cephalograms taken preoperatively; 1 week, 6 months and 14 months postoperatively; and at the final evaluation after an average of 12 years. Mean mandibular advancement was 4.1 mm at B-point and 4.9 mm at pogonion. Representing surgical mandibular ramus displacement, gonion moved downwards 2 mm immediately after surgery. During the short-term postoperative period, mandibular corpus length decreased only 0.5 mm, indicating that there was no osteotomy slippage. After the first year of observation, skeletal relapse was 1.3 mm at B-point and pogonion. The relapse continued, reaching a total of 2.3 mm after 12 years, corresponding to 50% of the mandibular advancement. Mandibular ramus length continuously decreased 1 mm during the same observation period, indicating progressive condylar resorption. No significant relationship between the amount of initial surgical advancement and skeletal relapse was found. Preoperative high mandibulo-nasal plane (ML-NL) angle appears to be associated with long-term skeletal relapse.
Resumo:
The early detection of subjects with probable Alzheimer's disease (AD) is crucial for effective appliance of treatment strategies. Here we explored the ability of a multitude of linear and non-linear classification algorithms to discriminate between the electroencephalograms (EEGs) of patients with varying degree of AD and their age-matched control subjects. Absolute and relative spectral power, distribution of spectral power, and measures of spatial synchronization were calculated from recordings of resting eyes-closed continuous EEGs of 45 healthy controls, 116 patients with mild AD and 81 patients with moderate AD, recruited in two different centers (Stockholm, New York). The applied classification algorithms were: principal component linear discriminant analysis (PC LDA), partial least squares LDA (PLS LDA), principal component logistic regression (PC LR), partial least squares logistic regression (PLS LR), bagging, random forest, support vector machines (SVM) and feed-forward neural network. Based on 10-fold cross-validation runs it could be demonstrated that even tough modern computer-intensive classification algorithms such as random forests, SVM and neural networks show a slight superiority, more classical classification algorithms performed nearly equally well. Using random forests classification a considerable sensitivity of up to 85% and a specificity of 78%, respectively for the test of even only mild AD patients has been reached, whereas for the comparison of moderate AD vs. controls, using SVM and neural networks, values of 89% and 88% for sensitivity and specificity were achieved. Such a remarkable performance proves the value of these classification algorithms for clinical diagnostics.
Resumo:
AIM: To compare the periodontal conditions of Swiss Army recruits in 2006 with those of previous surveys in 1996 and 1985. MATERIAL AND METHODS: A total of six hundred and twenty-six Swiss Army recruits were examined for their periodontal conditions, caries prevalence, stomatological and functional aspects of the masticatory system and halitosis. In particular, this report deals with demographic data, the assessment of plaque index (PlI), gingival index (GI) and pocket probing depth (PPD). RESULTS: Two per cent of all teeth were missing, resulting in a mean of 27.44 teeth per subject, and 77% of the missing teeth were the result of pre-molar extractions due to orthodontic indications. The mean PlI and GI were 1.33 and 1.23, respectively. On average, 27% of the gingival units bled on probing. The mean PPD was 2.16 mm (SD 0.64). Only 3.8% of the recruits showed at least one site of PPD > or = 5 mm, and 1.4% yielded more than one site with PPD > or = 5 mm. In comparison with previous, this survey yielded lower bleeding on probing (BOP) percentages than in 1985, but slightly higher scores than in 1996. This may be attributed to increased PlI scores in 2006. However, PPD remained essentially unaltered from 1996 to 2006 after having improved significantly from 1985. CONCLUSION: A significant improvement of the periodontal conditions of young Swiss males was demonstrated to have taken place between 1985 and 1996, but no further changes during the last decade were noticed.
Resumo:
In a retrospective multicentre study, the success rate and efficiency of activator treatment were analysed. All patients from two University clinics (Giessen, Germany and Berne, Switzerland) that fulfilled the selection criteria (Class II division 1 malocclusion, activator treatment, no aplasia, no extraction of permanent teeth, no syndromes, no previous orthodontic treatment except transverse maxillary expansion, full available records) were included in the study. The subject material amounted to 222 patients with a mean age of 10.6 years. Patient records, lateral head films, and dental casts were evaluated. Treatment was classified as successful if the molar relationship improved by at least half to three-fourths cusp width depending on whether or not the leeway space was used during treatment. Group comparisons were carried out using Wilcoxon two-sample and Kruskal-Wallis tests. For discrete data, chi-square analysis was used and Fisher's exact test when the sample size was small. Stepwise logistic regression was also employed. The success rate was 64 per cent in Giessen and 66 per cent in Berne. The only factor that significantly (P < 0.001) influenced treatment success was the level of co-operation. In approximately 27 per cent of the patients at both centres, the post-treatment occlusion was an 'ideal' Class I. In an additional 38 per cent of the patients, marked improvements in occlusal relationships were found. In subjects with Class II division 1 malocclusions, in which orthodontic treatment is performed by means of activators, a marked improvement of the Class II dental arch relationships can be expected in approximately 65 per cent of subjects. Activator treatment is more efficient in the late than in the early mixed dentition.
Resumo:
The purpose of the study was to analyse longitudinal vertical facial and dentoalveolar changes using panoramic radiographs (PRs) and to compare the results with measurements on lateral cephalometric radiographs (LCRs) in order to determine whether, under certain circumstances, the radiation dose for a patient may be reduced by taking only a PR instead of a PR and a LCR. Pre- and post-treatment PRs and LCRs of 30 (15 females and 15 males) orthodontically treated adolescents (mean age pre-treatment 10.9 years, post-treatment 13.4 years) were analysed using Pearson's correlation coefficients and gender differences using Fisher's z-transformation. The results revealed that most variables exhibited larger absolute values on PRs than on LCRs. Comparison of dentoskeletal morphology between the LCRs and the PRs revealed moderate to high, mostly statistically significant, interrelations both before and after orthodontic treatment. The lowest correlations were found for the maxillary jaw base angle (NL/H; r= 0.35***) and the highest for the gonial angle (ML/RL; r = 0.90***). However, when assessing the combined growth and treatment changes from before to after treatment, only weak to moderate, not statistically significant, interrelations were found between LCRs and PRs. Anterior face height (AFH; r = 0.43***), the mandibular plane angle (ML/H; r = 0.06*), and the distance of the incisal tip of the most extruded mandibular incisor to the ML-line (ii-ML; r = -0.21*) were the only statistically significant parameters. The average group differences for growth and treatment changes, however, were small for most parameters. Analysis of vertical facial and dentoalveolar parameters on PRs delivers a moderate approximation to the situation depicted on LCRs. However, PRs cannot be recommended for the analysis of individual longitudinal changes in vertical facial and dentoalveolar parameters.
Resumo:
Building energy meter network, based on per-appliance monitoring system, willbe an important part of the Advanced Metering Infrastructure. Two key issues exist for designing such networks. One is the network structure to be used. The other is the implementation of the network structure on a large amount of small low power devices, and the maintenance of high quality communication when the devices have electric connection with high voltage AC line. The recent advancement of low-power wireless communication makes itself the right candidate for house and building energy network. Among all kinds of wireless solutions, the low speed but highly reliable 802.15.4 radio has been chosen in this design. While many network-layer solutions have been provided on top of 802.15.4, an IPv6 based method is used in this design. 6LOWPAN is the particular protocol which adapts IP on low power personal network radio. In order to extend the network into building area without, a specific network layer routing mechanism-RPL, is included in this design. The fundamental unit of the building energy monitoring system is a smart wall plug. It is consisted of an electricity energy meter, a RF communication module and a low power CPU. The real challenge for designing such a device is its network firmware. In this design, IPv6 is implemented through Contiki operation system. Customize hardware driver and meter application program have been developed on top of the Contiki OS. Some experiments have been done, in order to prove the network ability of this system.
Resumo:
Wireless sensor network is an emerging research topic due to its vast and ever-growing applications. Wireless sensor networks are made up of small nodes whose main goal is to monitor, compute and transmit data. The nodes are basically made up of low powered microcontrollers, wireless transceiver chips, sensors to monitor their environment and a power source. The applications of wireless sensor networks range from basic household applications, such as health monitoring, appliance control and security to military application, such as intruder detection. The wide spread application of wireless sensor networks has brought to light many research issues such as battery efficiency, unreliable routing protocols due to node failures, localization issues and security vulnerabilities. This report will describe the hardware development of a fault tolerant routing protocol for railroad pedestrian warning system. The protocol implemented is a peer to peer multi-hop TDMA based protocol for nodes arranged in a linear zigzag chain arrangement. The basic working of the protocol was derived from Wireless Architecture for Hard Real-Time Embedded Networks (WAHREN).