995 resultados para Optical features
Resumo:
We describe the relative frequency, clinical features, neuroimaging and pathological results, and outcome after pharmacological or surgical intervention for a series of pediatric patients with temporal lobe epilepsy (TLE) from an epilepsy center in Brazil. The medical records of children younger than 12 years with features strongly suggestive of TLE were reviewed from January 1999 to June 1999. Selected children were evaluated regarding clinical, EEG, and magnetic resonance imaging (MRI) investigation and divided into three groups according to MRI: group 1 (G1, N = 9), patients with hippocampal atrophy; group 2 (G2, N = 10), patients with normal MRI, and group 3 (G3, N = 12), patients with other specific temporal lesions. A review of 1732 records of children with epilepsy revealed 31 cases with TLE (relative frequency of 1.79%). However, when the investigation was narrowed to cases with intractable seizures that needed video-EEG monitoring (N = 68) or epilepsy surgery (N = 32), the relative frequency of TLE increased to 19.11 (13/68) and 31.25% (10/32), respectively. At the beginning of the study, 25 of 31 patients had a high seizure frequency (80.6%), which declined to 11 of 31 (35.5%) at the conclusion of the study, as a consequence of pharmacological and/or surgical therapy. This improvement in seizure control was significant in G1 (P < 0.05) and G3 (P < 0.01) mainly due to good postsurgical outcome, and was not significant in G2 (P > 0.1, McNemar's test). These results indicate that the relative frequency of TLE in children was low, but increased considerably among cases with pharmacoresistant seizures. Patients with specific lesions were likely to undergo surgery, with good postoperative outcomes.
Resumo:
Feature extraction is the part of pattern recognition, where the sensor data is transformed into a more suitable form for the machine to interpret. The purpose of this step is also to reduce the amount of information passed to the next stages of the system, and to preserve the essential information in the view of discriminating the data into different classes. For instance, in the case of image analysis the actual image intensities are vulnerable to various environmental effects, such as lighting changes and the feature extraction can be used as means for detecting features, which are invariant to certain types of illumination changes. Finally, classification tries to make decisions based on the previously transformed data. The main focus of this thesis is on developing new methods for the embedded feature extraction based on local non-parametric image descriptors. Also, feature analysis is carried out for the selected image features. Low-level Local Binary Pattern (LBP) based features are in a main role in the analysis. In the embedded domain, the pattern recognition system must usually meet strict performance constraints, such as high speed, compact size and low power consumption. The characteristics of the final system can be seen as a trade-off between these metrics, which is largely affected by the decisions made during the implementation phase. The implementation alternatives of the LBP based feature extraction are explored in the embedded domain in the context of focal-plane vision processors. In particular, the thesis demonstrates the LBP extraction with MIPA4k massively parallel focal-plane processor IC. Also higher level processing is incorporated to this framework, by means of a framework for implementing a single chip face recognition system. Furthermore, a new method for determining optical flow based on LBPs, designed in particular to the embedded domain is presented. Inspired by some of the principles observed through the feature analysis of the Local Binary Patterns, an extension to the well known non-parametric rank transform is proposed, and its performance is evaluated in face recognition experiments with a standard dataset. Finally, an a priori model where the LBPs are seen as combinations of n-tuples is also presented
Resumo:
The structure and optical properties of thin films based on C60
Resumo:
In coastal waters, physico-chemical and biological properties and constituents vary at different time scales. In the study area of this thesis, within the Archipelago Sea in the northern Baltic Sea, seasonal cycles of light and temperature set preconditions for intra-annual variations, but developments at other temporal scales occur as well. Weather-induced runoffs and currents may alter water properties over the short term, and the consequences over time of eutrophication and global changes are to a degree unpredictable. The dynamic characteristics of northern Baltic Sea waters are further diversified at the archipelago coasts. Water properties may differ in adjacent basins, which are separated by island and underwater thresholds limiting water exchange, making the area not only a mosaic of islands but also one of water masses. Long-term monitoring and in situ observations provide an essential data reserve for coastal management and research. Since the seasonal amplitudes of water properties are so high, inter-annual comparisons of water-quality variables have to be based on observations sampled at the same time each year. In this thesis I compare areas by their temporal characteristics, using both inter-annual and seasonal data. After comparing spatial differences in seasonal cycles, I conclude that spatial comparisons and temporal generalizations have to be made with caution. In classifying areas by the state of their waters, the results may be biased even if the sampling is annually simultaneous, since the dynamics of water properties may vary according to the area. The most comprehensive view of the spatiotemporal dynamics of water properties would be achieved by means of comparisons with data consisting of multiple annual samples. For practical reasons, this cannot be achieved with conventional in situ sampling. A holistic understanding of the spatiotemporal features of the water properties of the Archipelago Sea will have to be based on the application of multiple methods, complementing each other’s spatial and temporal coverage. The integration of multi-source observational data and time-series analysis may be methodologically challenging, but it will yield new information as to the spatiotemporal regime of the Archipelago Sea.
Resumo:
In a serial feature-positive conditional discrimination procedure the properties of a target stimulus A are defined by the presence or not of a feature stimulus X preceding it. In the present experiment, composite features preceded targets associated with two different topography operant responses (right and left bar pressing); matching and non-matching-to-sample arrangements were also used. Five water-deprived Wistar rats were trained in 6 different trials: X-R®Ar and X-L®Al, in which X and A were same modality visual stimuli and the reinforcement was contingent to pressing either the right (r) or left (l) bar that had the light on during the feature (matching-to-sample); Y-R®Bl and Y-L®Br, in which Y and B were same modality auditory stimuli and the reinforcement was contingent to pressing the bar that had the light off during the feature (non-matching-to-sample); A- and B- alone. After 100 training sessions, the animals were submitted to transfer tests with the targets used plus a new one (auditory click). Average percentages of stimuli with a response were measured. Acquisition occurred completely only for Y-L®Br+; however, complex associations were established along training. Transfer was not complete during the tests since concurrent effects of extinction and response generalization also occurred. Results suggest the use of both simple conditioning and configurational strategies, favoring the most recent theories of conditional discrimination learning. The implications of the use of complex arrangements for discussing these theories are considered.
Resumo:
Human T-cell lymphotropic virus type 1 (HTLV-1) induces an exacerbated type 1 immune response characterized by high spontaneous IFN-γ and TNF-α production. Allergic rhinitis and asthma are associated with the type 2 immune response, with elevated secretion of IL-4 and IL-5. The aim of this study was to characterize the immune response in atopic HTLV-1 carriers. The cytokine profile of atopic HTLV-1 carriers (N = 10; all females) was compared with that of non-atopic HTLV-1 carriers (N = 14; 9 females and 5 males). Mean patient age of atopic and non-atopic groups was 45 ± 8 and 38 ± 11 years, respectively. All atopic HTLV-1 carriers had rhinitis with or without asthma and a skin prick test positive for Dermatophagoides pteronyssinus antigen 1 (Derp-1). There was no difference in cytokine levels between the two groups in unstimulated peripheral blood mononuclear cell cultures. In cultures stimulated with Derp-1, IFN-γ levels tended to be higher (P = 0.06) and IL-5 levels were higher (P = 0.02) in atopic HTLV-1 patients than in non-atopic subjects. In contrast, IL-10 was lower (P = 0.004) in atopic than in non-atopic HTLV-1-infected subjects. This study shows that HTLV-1 infection with an exaggerated type 1 immune response does not prevent atopy. In this case, the exacerbated type 1 and type 2 immune responses were due to a lack of IL-10 production, a cytokine that plays an important role in down-modulating type 1 and type 2 immune responses and in preventing the development of chronic inflammatory diseases.
Resumo:
The objective of the present cross-sectional study was to assess the prevalence and the clinical and laboratory features of hepatitis C virus (HCV)-positive patients with type 2 diabetes mellitus (DM) attending either an outpatient clinic or hemodialysis units. Serologic-HCV testing was performed in 489 type 2 DM patients (303 outpatients and 186 on dialysis). A structured assessment of clinical, laboratory and DM-related complications was performed and the patients were then compared according to HCV infection status. Mean patient age was 60 years; HCV positivity (HCV+) was observed in 39 of 303 (12.9%) outpatients and in 34 of 186 (18.7%) dialysis patients. Among HCV+ patients, 32 were men (43.8%). HCV+ patients had higher serum levels of aspartate aminotransferase (0.90 ± 0.83 vs 0.35 ± 0.13 µKat/L), alanine aminotransferase (0.88 ± 0.93 vs 0.38 ± 0.19 µKat/L), gamma-glutamyl transferase (1.57 ± 2.52 vs 0.62 ± 0.87 µKat/L; P < 0.001), and serum iron (17.65 ± 6.68 vs 14.96 ± 4.72 µM; P = 0.011), and lower leukocyte and platelet counts (P = 0.010 and P < 0.001, respectively) than HCV-negative (HCV-) patients. HCV+ dialysis patients had higher diastolic blood pressure than HCV- patients (87.5 ± 6.7 vs 81.5 ± 6.0 mmHg; P = 0.005) and a lower prevalence of diabetic retinopathy (75 vs 92.7%; P = 0.007). In conclusion, our study showed that HCV is common among subjects with type 2 DM but is not associated with a higher prevalence of chronic diabetic complications.
Resumo:
Oculo-facio-cardio-dental (OFCD) syndrome is a rare X-linked disorder mainly manifesting in females. Patients show ocular, facial, cardiac, and dental abnormalities. OFCD syndrome is caused by heterozygous mutations in the BCOR gene, located in Xp11.4, encoding the BCL6 co-repressor. We report a Croatian family with four female members (grandmother, mother and monozygotic female twins) diagnosed with OFCD syndrome who carry the novel BCOR mutation c.4438C>T (p.R1480*). They present high intrafamilial phenotypic variability with special regard to cardiac defect and cataract that showed more severe disease expression in successive generations. Clinical and radiographic examination of the mother of the twins revealed a talon cusp involving the permanent maxillary right central incisor. This is the first known report of a talon cusp in OFCD syndrome with a novel mutation in the BCOR gene.
Resumo:
This study aimed to explore the correlations between cadherin-17 (CDH17) protein expression and the clinicopathological features and prognosis of patients with sporadic gastric cancer (GC). Nine relevant studies of 1,960 patients were identified using electronic database searches supplemented with a manual search in strict accordance with inclusion and exclusion criteria. Statistical analyses were conducted using STATA 12.0 statistical software. Relative risks and 95% confidence intervals were determined, and Z test was used to measure the significance of the overall effect size. A total of nine eligible cohort studies were included in this meta-analysis. The expression of CDH17 in patients with diffuse GC was significantly higher than in those with intestinal-type GC. Moreover, the tumor depth of invasion differed significantly between patients with positive CDH17 (CDH17+) and negative CDH17 (CDH17-) GC. However, there were no significant differences between CDH17+ and CDH17- GC patients with respect to tumor node metastasis clinical stages, histological grades, or lymph node metastasis. Despite the differences in invasive depth, there was no significant difference in 5-year survival rates between CDH17+ and CDH17- GC patients. Our meta-analysis provides evidence that CDH17 protein expression may be associated with the development of GC, suggesting that CDH17 is an important biomarker that could be useful for the early diagnosis of GC. However, CDH17 levels do not appear to impact overall survival.
Resumo:
Optical coherence tomography (OCT) is a promising medical imaging technique that uses light to capture real-time cross-sectional images from biological tissues in micrometer resolution. Commercially available optical coherence tomography systems are employed in diverse applications, including art conservation and diagnostic medicine, notably in cardiology and ophthalmology. Application of this technology in the brain may enable distinction between white matter and gray matter, and obtainment of detailed images from within the encephalon. We present, herein, the in vivo implementation of OCT imaging in the rat brain striatum. For this, two male 60-day-old rats (Rattus norvegicus, Albinus variation, Wistar) were stereotactically implanted with guide cannulas into the striatum to guide a 2.7-French diameter high-definition OCT imaging catheter (Dragonfly™, St. Jude Medical, USA). Obtained images were compared with corresponding histologically stained sections to collect imaging samples. A brief analysis of OCT technology and its current applications is also reported, as well as intra-cerebral OCT feasibility on brain mapping during neurosurgical procedures.
Resumo:
Upconversion photoluminescence is a unique property of mostly certain inorganic materials, which are capable of converting low-energy infrared radiation into a higher-energy emission at visible wavelengths. This anti-Stokes shift enables luminescence detection without autofluorescence, which makes the upconverting materials a highly suitable reporter technology for optical biosensing applications. Furthermore, they exhibit long luminescence lifetime with narrow bandwidths also at the optical window of biomaterials enabling luminescence measurements in challenging sample matrices, such as whole blood. The aim of this thesis was to study the unique properties and the applicability of nano-sized upconverting phosphors (UCNPs) as reporters in biosensing applications. To render the inorganic nanophosphors water-dispersible and biocompatible, they were subjected to a series of surface modifications starting with silica-encapsulation and ending with a bioconjugation step with an analyte-recognizing biomolecule. The paramagnetism of the lanthanide dopants in the nanophosphors was exploited to develop a highly selective separation method for the UCNP-bioconjugates based on the magnetic selectivity of the high gradient magnetic separation (HGMS) system. The applicability of the nano-sized UCNPs as reporters in challenging sample matrices was demonstrated in two homogeneous sensing applications based on upconversion resonance energy transfer (UC-RET). A chemosensor for intracellular pH was developed exploiting UC-RET between the UCNP and a fluorogenic pH-sensitive dye with strongly increasing fluorescence intensity in decreasing pH. The pH-independent emission of the UCNPs at 550 nm was used for referencing. The applicability of the pH-nanosensor for intracellular pH measurement was tested in HeLa cells, and the acidic pH of endosomes could be detected with a confocal fluorescence microscope. Furthermore, a competitive UC-RET-based assay for red blood cell folic acid was developed for the measurement of folate directly from a whole blood sample. The optically transparent window of biomaterials was used in both the excitation and the measurement of the UC-RET sensitized emission of a near-infrared acceptor dye to minimize sample absorption, and the anti-Stokes detection completely eliminated the Stokes-shifted autofluorescence. The upconversion photoluminescence efficiency is known to be dependent on crystallite size, because the increasing surface-to-volume ratio of nano-sized UCNPs renders them more susceptible to quenching effects of the environment than their bulk counterpart. Water is known to efficiently quench the luminescence of lanthanide dopants. In this thesis, the quenching mechanism of water was studied using luminescence decay measurements. Water was found to quench the luminescence of UCNPs by increasing the non-radiative relaxation of the excited state of Yb3+ sensitizer ion, which had a very strong quenching effect on upconversion luminescence intensity.
Resumo:
Weldability of powder bed fusion (PBF) fabricated components has come to discussion in past two years due to resent developments in the PBF technology and limited size of the machines used in the fabrication process. This study concentrated on effects of energy input of welding on mechanical properties and microstructural features of welds between PBF fabricated stainless steel 316L sheets and cold rolled sheet metal of same composition by the means of destructive testing and microscopic analysis. Optical fiber diameter, laser power and welding speed were varied during the experiments that were executed following one variable at a time (OVAT) method. One of the problems of welded PBF fabricated components has been lower elongations at break comparing to conventionally manufactured components. Decreasing energy input of the laser keyhole welding decreased elongations at break of the welded specimens. Ultimate tensile strengths were not affected significantly by the energy input of the welding, but fracturing of the specimens welded using high energy input occurred from the weld metal. Fracturing of the lower energy input welds occurred from the PBF fabricated base metal. Energy input was found to be critical factor for mechanical properties of the welds. Multioriented grain growth and formation of neck at fusion zone boundary on the cold rolled side of the weld was detected and suspected to be result from weld pool flows caused by differences in molten weld pool behaviour between the PBF fabricated and cold rolled sides of the welds.
Resumo:
Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.
Resumo:
Quantum computation and quantum communication are two of the most promising future applications of quantum mechanics. Since the information carriers used in both of them are essentially open quantum systems it is necessary to understand both quantum information theory and the theory of open quantum systems in order to investigate realistic implementations of such quantum technologies. In this thesis we consider the theory of open quantum systems from a quantum information theory perspective. The thesis is divided into two parts: review of the literature and original research. In the review of literature we present some important definitions and known results of open quantum systems and quantum information theory. We present the definitions of trace distance, two channel capacities and superdense coding capacity and give a reasoning why they can be used to represent the transmission efficiency of a communication channel. We also show derivations of some properties useful to link completely positive and trace preserving maps to trace distance and channel capacities. With the help of these properties we construct three measures of non-Markovianity and explain why they detect non-Markovianity. In the original research part of the thesis we study the non-Markovian dynamics in an experimentally realized quantum optical set-up. For general one-qubit dephasing channels we calculate the explicit forms of the two channel capacities and the superdense coding capacity. For the general two-qubit dephasing channel with uncorrelated local noises we calculate the explicit forms of the quantum capacity and the mutual information of a four-letter encoding. By using the dynamics in the experimental implementation as a set of specific dephasing channels we also calculate and compare the measures in one- and two-qubit dephasing channels and study the options of manipulating the environment to achieve revivals and higher transmission rates in superdense coding protocol with dephasing noise. Kvanttilaskenta ja kvanttikommunikaatio ovat kaksi puhutuimmista tulevaisuuden kvanttimekaniikan käytännön sovelluksista. Koska molemmissa näistä informaatio koodataan systeemeihin, jotka ovat oleellisesti avoimia kvanttisysteemejä, sekä kvantti-informaatioteorian, että avointen kvanttisysteemien tuntemus on välttämätöntä. Tässä tutkielmassa käsittelemme avointen kvanttisysteemien teoriaa kvantti-informaatioteorian näkökulmasta. Tutkielma on jaettu kahteen osioon: kirjallisuuskatsaukseen ja omaan tutkimukseen. Kirjallisuuskatsauksessa esitämme joitakin avointen kvanttisysteemien ja kvantti-informaatioteorian tärkeitä määritelmiä ja tunnettuja tuloksia. Esitämme jälkietäisyyden, kahden kanavakapasiteetin ja superdense coding -kapasiteetin määritelmät ja esitämme perustelun sille, miksi niitä voidaan käyttää kuvaamaan kommunikointikanavan lähetystehokkuutta. Näytämme myös todistukset kahdelle ominaisuudelle, jotka liittävät täyspositiiviset ja jäljensäilyttävät kuvaukset jälkietäisyyteen ja kanavakapasiteetteihin. Näiden ominaisuuksien avulla konstruoimme kolme epä-Markovisuusmittaa ja perustelemme, miksi ne havaitsevat dynamiikan epä-Markovisuutta. Oman tutkimuksen osiossa tutkimme epä-Markovista dynamiikkaa kokeellisesti toteutetussa kvanttioptisessa mittausjärjestelyssä. Yleisen yhden qubitin dephasing-kanavan tapauksessa laskemme molempien kanavakapasiteettien ja superdense coding -kapasiteetin eksplisiittiset muodot. Yleisen kahden qubitin korreloimattomien ympäristöjen dephasing-kanavan tapauksessa laskemme yhteisen informaation lausekkeen nelikirjaimisessa koodauksessa ja kvanttikanavakapasiteetin. Käyttämällä kokeellisen mittajärjestelyn dynamiikkoja esimerkki dephasing-kanavina me myös laskemme konstruoitujen epä-Markovisuusmittojen arvot ja vertailemme niitä yksi- ja kaksi-qubitti-dephasing-kanavissa. Lisäksi käyttäen kokeellisia esimerkkikanavia tutkimme, kuinka ympäristöä manipuloimalla superdense coding –skeemassa voidaan saada yhteinen informaatio ajoittain kasvamaan tai saavuttaa kaikenkaikkiaan korkeampi lähetystehokkuus.
Resumo:
Optical coherence tomography (OCT) is a novel intracoronary imaging application for the assessment of native lesions and coronary stents. The purpose of this thesis was to evaluate the safety and feasibility of frequency-domain OCT (FD-OCT) based on experiences of the Satakunta Central Hospital (I). Early vascular healing was evaluated after implantation of endothelial progenitor cell capturing (II) and bio-active titanium-nitride-oxide coated stents (III) in two studies, each with 20 patients. Vascular healing was also compared after implantation of bio-active and everolimus-eluting stents on 28 patients after 9-month follow-up (IV). Long-term vascular healing of bio-active and paclitaxel-eluting stents was assessed in the last study with 18 patients (V). The results indicate that FD-OCT is safe and feasible (I). Both bio-active and endothelial progenitor cell capturing stents showed near-complete endothelialisation after one-month follow-up, which is desirable when prolonged dual anti-platelet therapy needs to be avoided after stenting (II and III). Endothelialisation of bio-active stents showed a predictable pattern at mid-term and long-term follow up (IV and V). Endothelialisation of everolimus-eluting stents was not complete at 9 months follow-up, which may suggest that interruption of dual antiplatelet therapy at this time point may not be safe (IV). Finally, delayed vascular healing may be present in patients treated with paclitaxel-eluting stents as long as 4 years from implantation, which reinforces the previously raised concerns on the long-term safety of this device (V).