996 resultados para Multicenter Evaluation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reuse of waste fluid catalytic cracking (FCC) catalyst as partial surrogate for cement can reduce the environmental impact of both the oil-refinery and cement production industries [1,2]. FCC catalysts can be considered as pozzolanic materials since in the presence of water they tend to chemically react with calcium hydroxide to produce compounds possessing cementitious properties [3,4]. In addition, partial replacement of cement with FCC catalysts can enhance the performance of pastes and mortars, namely by improving their compressive strength [5,6]. In the present work the reaction of waste FCC catalyst with Ca(OH)2 has been investigated after a curing time of 28 days by scanning electron microscopy (SEM) with electron backscattered signal (BSE) combined with X-ray energy dispersive spectroscopy (EDS) carried out with a JEOL JSM 7001F instrument operated at 15 kV coupled to an INCA pentaFetx3 Oxford spectrometer. The polished cross-sections of FCC particles embedded in resin have also been evaluated by atomic force microscopy (AFM) in contact mode (CM) using a NanoSurf EasyScan 2 instrument. The SEM/EDS results revealed that an inward migration of Ca occurred during the reaction. A weaker outward migration of Si and Al was also apparent (Fig. 1). The migration of Ca was not homogeneous and tended to follow high-diffusivity paths within the porous waste FCC catalyst particles. The present study suggests that the porosity of waste FCC catalysts is key for the migration/reaction of Ca from the surrounding matrix, playing an important role in the pozzolanic activity of the system. The topography images and surface roughness parameters obtained by atomic force microscopy can be used to infer the local porosity in waste FCC catalyst particles (Fig. 2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comunicação apresentada na IASIA Annual Conference no Rio de Janeiro, Brasil, de 3 a 8 de Agosto de 2009.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dot-ELISA using a measles virus (MV) antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immuno fluorescence test (IFT) were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00). Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85) was higher than that (0.63) of the IgM IFT, although both assays had comparably high (1.00) specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15) of vaccinated children on the 15th day after immunization. In contrast the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, more than 500,000 new cases of malaria were notified in 1992. Plasmodium falciparum and P.vivax are the responsible species for 99.3% of the cases. For adequate treatment, precoce diagnosis is necessary. In this work, we present the results of the traditional Plasmodia detection method, thick blood film (TBF), and the results of alternative methods: Immunofluorescence assay (IFA) with polyclonal antibody and Quantitative Buffy Coat method (QBC)® in a well defined population groups. The analysis were done in relation to the presence or absence of malaria clinical symptoms. Also different classes of immunoglobulins anti-P.falciparum were quantified for the global analysis of the results, mainly in the discrepant results. We concluded that alternative methods are more sensitive than TBF and that the association of epidemiological, clinical and laboratory findings is necessary to define the presence of malaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of resistance in three stages throughout an active infection (pre-ovular, acute and initial chronic stages) was studied, comparing the total number of adult worms recovered from the reinfected group and the control groups. It was shown that Nectomys squamipes was unable to develop resistance in the tested conditions and, on the other hand, reinfection in the pre-ovular period of the parasite led the rodent to present the phenomenonacilitation, with reduction of natural resistance and an increase in the parasite load. These results suggest the existence of other forms of immunity diverse from the concomitant immunity in the host-parasite relationship, according to the employed model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se evaluó la utilidad de la prueba de aglutinación directa (AD) para diagnosticar el Mal de Caderas. Se emplearon cuarenta y cuatro sueros provenientes de dos lotes de equinos naturalmente infectados con el Trypanosoma evansi (Lote 1 y Lote 2). La AD fue positiva (Aglutinación > 1:512) en 13 de 16 equinos (81.2%), de los que se aislaron los parásitos. En doce de estos animales (92%) se detectaron IgM anti T. evansi mediante la AD realizada con 2-mercaptoetanol (AD + 2-ME). La AD fue positiva en 17 de los 28 equinos que resultaron negativos al diagnóstico parasitológico. Un tercer lote de cinco equinos infectados con T. evansi que presentaba elevados títulos de AD, fue tratado con Suramina Sódica (Nagano1-Bayer). La AD + 2-ME evidenció en cuatro animales que, gran parte de estos anticuerpos se ubicaban en la fracción IgM. Posterior al tratamiento farmacológico y, en concordancia de la negativización de la parasitemia, la detección de la IgM anti T. evansi no fue posible, mientras que los anticuerpos IgG continuaron detectándose a los doce meses post-tratamiento en valores de 1:512, en tres animales. Cincuenta sueros de equinos de una zona libre del parásito, que se emplearon como controles, fueron negativos a la AD. Se recomienda la utilización de la AD y AD + 2-ME para el uso de rutina en el diagnóstico del Mal de Caderas de los equinos, en combinación con otros métodos parasitológicos sensibles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 130 Listeria strains were tested in order to evaluate lecithinase production and capacity for Congo red adsorption as markers of pathogenicity. The strains were identified according to acid production from sugars and by the CAMP test and the data were correlated with the ability to produce keratoconjunctivitis in guinea pigs. L. monocytogenes cultures presented 51.8% and 88.8% positivity rates for Congo red adsorption and lecithinase production, respectively, whereas 80.8% and 100% for L. innocua cultures were negative for the two test, respectively

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sixteen patients with endemic pemphigus foliaceus were submitted to nutritional evaluation. Ten had the localized form of the disease (Group G1) and six the disseminated form (Group G2). The patients were submitted to anthropometric measurements (weight, height, Quetelét index, tricipital skin fold, subscapular skin fold, arm circumference, arm muscle circumference, arm area, arm muscle area, and arm adipose area) and to laboratory evaluation by protein electrophoresis. Arm circumference, arm area and arm muscle area showed lower values in G2 than in G1. Weight and arm muscle circumference tended to the lower in G2 than in G1. Protein electrophoresis showed decreased albumin levels in both groups, with lower values in G2. Overall analysis of the results permits us to conclude that patients with endemic pemphigus foliaceus present signs and symptoms of protein, but not calorie, malnutrition and that this malnutrition is more marked in patients with disseminated pemphigus foliaceus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The currently used pre-exposure anti-rabies immunization schedule in Brazil is the one called 3+1, employing suckling mouse brain vaccine (3 doses on alternate days and the last one on day 30). Although satisfactory results were obtained in well controlled experimental groups using this immunization schedule, in our routine practice, VNA levels lower than 0.5 IU/ml are frequently found. We studied the pre-exposure 3+1 schedule under field conditions in different cities on the State of São Paulo, Brazil, under variable and sometimes adverse circumstances, such as the use of different batches of vaccine with different titers, delivered, stored and administered under local conditions. Fifty out of 256 serum samples (19.5%) showed VNA titers lower than 0.5 IU/ml, but they were not distributed homogeneously among the localities studied. While in some cities the results were completely satisfactory, in others almost 40% did not attain the minimum VNA titer required. The results presented here, considered separately, question our currently used procedures for human pre-exposure anti-rabies immunization. The reasons determining this situation are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports preliminary results of virus neutralizing antibody (VNA) titers obtained on different days in the course of human anti-rabies immunization with the 2-1-1 schedule (one dose is given in the right arm and one dose in the left arm at day 0, and one dose is apllied on days 7 and 21), recommended by WHO for post-exposure treatment with cell culture vaccines. A variant schedule (double dose on day zero and another on day 14) was also tested, both employing suckling mouse brain vaccine. A complete seroconversion rate was obtained after only 3 vaccine doses, and almost all patients (11 of 12) presented titers higher than 1.0 IU/ml. Both neutralizing response and seroconversion rates were lower in the group receiving only 3 doses, regardless of the sample collecting day. Although our results are lower than those found with cell culture vaccines, the geometry mean of VNA is fully satisfactory, overcoming the lower limit recommended by WHO of 0.5 IU/ml. The 2-1-1 schedule could be an alternative one for pre exposure immunization, shorter than the classical 3+1 regimen (one dose on days 0, 2, 4 and 30) with only three visits to the doctor, instead of four.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focuses on the Portuguese results from an international survey on LIS students’ information literacy skills. The results’ analysis will be grounded on a literature review on the criteria application to evaluate information and determine the credibility by undergraduate students. The guidelines for the information evaluation, especially regarding credibility aspect, on three main information literacy frameworks will be presented. After an overall presentation of the main results, the analysis of the Portuguese survey results will focus on issues related to information evaluation skills, namely on criteria to assess information credibility and on difficulties to apply them.