929 resultados para Mixed method
Resumo:
The Ponseti method is reportedly effective for treating clubfoot in children up to 9 years of age. However, whether age at the beginning of treatment influences the rate of successful correction and the rate of relapse is unknown. We therefore retrospectively reviewed 68 consecutive children with 102 idiopathic clubfeet treated by the Ponseti technique in four Portuguese hospitals. We followed patients a minimum of 30 months (mean, 41.4 months; range, 30–61 months). The patients were divided into two groups according to their age at the beginning of treatment; Group I was younger than 6 months and Group II was older than 6 months. All feet(100%) were initially corrected and no feet required extensive surgery regardless of age at the beginning of treatment. There were no differences between Groups I and II in the number of casts, tenotomies, success in terms of rate of initial correction, rate of recurrence, and rate of tibialis anterior transference. The rate of the Ponseti method in avoiding extensive surgery was 100% in Groups I and II; relapses occurred in 8% of the feet in younger and older children. Level of Evidence: Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Resumo:
Tipicamente as redes elétricas de distribuição apresentam uma topologia parcialmente malhada e são exploradas radialmente. A topologia radial é obtida através da abertura das malhas nos locais que otimizam o ponto de operação da rede, através da instalação de aparelhos de corte que operam normalmente abertos. Para além de manterem a topologia radial, estes equipamentos possibilitam também a transferência de cargas entre saídas, aquando da ocorrência de defeitos. As saídas radiais são ainda dotadas de aparelhos de corte que operam normalmente fechados, estes têm como objetivo maximizar a fiabilidade e isolar defeitos, minimizando a área afetada pelos mesmos. Assim, na presente dissertação são desenvolvidos dois algoritmos determinísticos para a localização ótima de aparelhos de corte normalmente abertos e fechados, minimizando a potência ativa de perdas e o custo da energia não distribuída. O algoritmo de localização de aparelhos de corte normalmente abertos visa encontrar a topologia radial ótima que minimiza a potência ativa de perdas. O método é desenvolvido em ambiente Matlab – Tomlab, e é formulado como um problema de programação quadrática inteira mista. A topologia radial ótima é garantida através do cálculo de um trânsito de potências ótimo baseado no modelo DC. A função objetivo é dada pelas perdas por efeito de Joule. Por outro lado o problema é restringido pela primeira lei de Kirchhoff, limites de geração das subestações, limites térmicos dos condutores, trânsito de potência unidirecional e pela condição de radialidade. Os aparelhos de corte normalmente fechados são localizados ao longo das saídas radiais obtidas pelo anterior algoritmo, e permite minimizar o custo da energia não distribuída. No limite é possível localizar um aparelho de corte normalmente fechado em todas as linhas de uma rede de distribuição, sendo esta a solução que minimiza a energia não distribuída. No entanto, tendo em conta que a cada aparelho de corte está associado um investimento, é fundamental encontrar um equilíbrio entre a melhoria de fiabilidade e o investimento. Desta forma, o algoritmo desenvolvido avalia os benefícios obtidos com a instalação de aparelhos de corte normalmente fechados, e retorna o número e a localização dos mesmo que minimiza o custo da energia não distribuída. Os métodos apresentados são testados em duas redes de distribuição reais, exploradas com um nível de tensão de 15 kV e 30 kV, respetivamente. A primeira rede é localizada no distrito do Porto e é caraterizada por uma topologia mista e urbana. A segunda rede é localizada no distrito de Bragança e é caracterizada por uma topologia maioritariamente aérea e rural.
Resumo:
As juntas adesivas têm vindo a ser usadas em diversas áreas e contam com inúmeras aplicações práticas. Devido ao fácil e rápido fabrico, as juntas de sobreposição simples (JSS) são um tipo de configuração bastante comum. O aumento da resistência, a redução de peso e a resistência à corrosão são algumas das vantagens que este tipo de junta oferece relativamente aos processos de ligação tradicionais. Contudo, a concentração de tensões nas extremidades do comprimento da ligação é uma das principais desvantagens. Existem poucas técnicas de dimensionamento precisas para a diversidade de ligações que podem ser encontradas em situações reais, o que constitui um obstáculo à utilização de juntas adesivas em aplicações estruturais. O presente trabalho visa comparar diferentes métodos analíticos e numéricos na previsão da resistência de JSS com diferentes comprimentos de sobreposição (LO). O objectivo fundamental é avaliar qual o melhor método para prever a resistência das JSS. Foram produzidas juntas adesivas entre substratos de alumínio utilizando um adesivo époxido frágil (Araldite® AV138), um adesivo epóxido moderadamente dúctil (Araldite® 2015), e um adesivo poliuretano dúctil (SikaForce® 7888). Consideraram-se diferentes métodos analíticos e dois métodos numéricos: os Modelos de Dano Coesivo (MDC) e o Método de Elementos Finitos Extendido (MEFE), permitindo a análise comparativa. O estudo possibilitou uma percepção crítica das capacidades de cada método consoante as características do adesivo utilizado. Os métodos analíticos funcionam apenas relativamente bem em condições muito específicas. A análise por MDC com lei triangular revelou ser um método bastante preciso, com excepção de adesivos que sejam bastante dúcteis. Por outro lado, a análise por MEFE demonstrou ser uma técnica pouco adequada, especialmente para o crescimento de dano em modo misto.
Resumo:
Dissertação para obtenção do Grau de Doutor em Matemática
Resumo:
OBJECTIVE: Combined hyperlipidaemia is a common and highly atherogenic lipid phenotype with multiple lipoprotein abnormalities that are difficult to normalise with single-drug therapy. The ATOMIX multicentre, controlled clinical trial compared the efficacy and safety of atorvastatin and bezafibrate in patients with diet-resistant combined hyperlipidaemia. PATIENTS AND STUDY DESIGN: Following a 6-week placebo run-in period, 138 patients received atorvastatin 10mg or bezafibrate 400mg once daily in a randomised, double-blind, placebo-controlled trial. To meet predefined low-density lipoprotein-cholesterol (LDL-C) target levels, atorvastatin dosages were increased to 20mg or 40mg once daily after 8 and 16 weeks, respectively. RESULTS: After 52 weeks, atorvastatin achieved greater reductions in LDL-C than bezafibrate (percentage decrease 35 vs 5; p < 0.0001), while bezafibrate achieved greater reductions in triglyceride than atorvastatin (percentage decrease 33 vs 21; p < 0.05) and greater increases in high-density lipoprotein-cholesterol (HDL-C) [percentage increase 28 vs 17; p < 0.01 ]. Target LDL-C levels (according to global risk) were attained in 62% of atorvastatin recipients and 6% of bezafibrate recipients, and triglyceride levels <200 mg/dL were achieved in 52% and 60% of patients, respectively. In patients with normal baseline HDL-C, bezafibrate was superior to atorvastatin for raising HDL-C, while in those with baseline HDL-C <35 mg/dL, the two drugs raised HDL-C to a similar extent after adjustment for baseline values. Both drugs were well tolerated. CONCLUSION: The results show that atorvastatin has an overall better efficacy than bezafibrate in concomitantly reaching LDL-C and triglyceride target levels in combined hyperlipidaemia, thus supporting its use as monotherapy in patients with this lipid phenotype.
Resumo:
Dissertation to obtain the Master Degree in Biotechnology
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Resumo:
Canine dirofilariosis is a life-threatening parasitic disease that is increasingly reported worldwide. Once diagnosed the main treatment goals are to improve the animal's clinical condition and to eliminate all life stages of the parasite with minimal posttreatment side effects. This can be achieved through mechanical, surgical, or chemotherapeutical approaches. Currently, manual extraction is the preferred method to remove adult heartworms due to its diminished invasiveness, reduced damage to the vascular endothelium, and shortened anaesthesia duration. However, it remains an expensive technique that can be highly traumatic. To address this issue, a nontraumatic homemade catheter-guided snare was developed for heartworm removal by adapting and folding a 0.014-inch coronary wire (BMW, Abbott Vascular). Transvenous heartworm extraction was performed on a dog severely infected with adult heartworms by inserting the modified snare into a 6-F Judkins right coronary guiding catheter BMW (Cordis) and advancing it into the right ventricle under fluoroscopic guidance. Fifteen adult specimens of Dirofilaria immitis were successfully extracted from the pulmonary artery and right ventricle without complications. To assure the death of both larvae and adults, postoperative treatment was successfully managed using ivermectin, doxycycline, and melarsomine, with no recurrence after surgery.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering
Resumo:
Dissertation presented to obtain the Ph.D degree in Chemistry.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica
Resumo:
INTRODUCTION: Spontaneous sedimentation is an important procedure for stool examination. A modification of this technique using conical tubes was performed and evaluated. METHODS: Fifty fecal samples were processed in sedimentation glass and in polypropylene conical tubes. Another 50 samples were used for quantitative evaluation of protozoan cysts. RESULTS: Although no significant differences occurred in the frequency of protozoa and helminths detected, significant differences in protozoan cyst counts did occur. CONCLUSIONS: The use of tube predicts a shorter path in the sedimentation of the sample, increases concentration of parasites for microscopy analysis, minimizes the risks of contamination, reduces the odor, and optimizes the workspace.