928 resultados para Masks (Sculpture)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single photon emission with computed tomography (SPECT) hexamethylphenylethyleneamineoxime technetium-99 images were analyzed by an optimal interpolative neural network (OINN) algorithm to determine whether the network could discriminate among clinically diagnosed groups of elderly normal, Alzheimer disease (AD), and vascular dementia (VD) subjects. After initial image preprocessing and registration, image features were obtained that were representative of the mean regional tissue uptake. These features were extracted from a given image by averaging the intensities over various regions defined by suitable masks. After training, the network classified independent trials of patients whose clinical diagnoses conformed to published criteria for probable AD or probable/possible VD. For the SPECT data used in the current tests, the OINN agreement was 80 and 86% for probable AD and probable/possible VD, respectively. These results suggest that artificial neural network methods offer potential in diagnoses from brain images and possibly in other areas of scientific research where complex patterns of data may have scientifically meaningful groupings that are not easily identifiable by the researcher.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As Ciências Forenses empregam a técnica de Reconstrução Facial buscando aumentar as possibilidades de reconhecimento humano. Após análise antropológica, a face é esculpida sobre o crânio esqueletizado e divulgada na mídia. Existem várias metodologias para a modelagem do rosto e das características da face, bem como vários dados de espessuras de tecidos moles que auxiliam no contorno facial. Com o intuito de investigar se existe uma metodologia que favoreça mais reconhecimentos e que permita uma maior semelhança com o indivíduo, este trabalho buscou comparar reconstruções faciais manuais feitas com duas abordagens para o preenchimento dos tecidos moles (métodos Americano e de Manchester) e para a predição dos olhos, nariz, boca e orelhas. Também buscou comparar reconstruções realizadas com quatro tabelas de espessuras de tecidos moles, desenvolvidas para brasileiros por estudos prévios, observando a possibilidade de unir esses dados para auxiliar na reconstrução. Um quarto objetivo foi averiguar se existe influência do sexo e do conhecimento anatômico ou forense na frequência de reconhecimentos. O estudo foi dividido em duas fases. Na primeira, duas reconstruções foram realizadas para dois indivíduos alvos (um homem e uma mulher) com os métodos Americano e de Manchester, aplicando dois guias para olhos, nariz, boca e orelhas. As reconstruções foram avaliadas por quarenta indivíduos (homens e mulheres, divididos em 4 grupos - alunos de graduação em Odontologia que não passaram pela disciplina de Odontologia Legal, alunos de graduação em Odontologia que passaram pela disciplina, especialistas em Odontologia Legal e indivíduos que não possuíam conhecimento de anatomia humana) por meio dos testes de reconhecimento e semelhança. Para o alvo feminino, as frequências de reconhecimentos foram 20% e 10% para os métodos Americano e de Manchester, respectivamente; para o alvo masculino, as frequências foram 35% e 17,5%. Em relação à semelhança, as medianas foram menores que 3 (em uma escala de 1 a 5); entretanto, foi verificada uma exceção para a escultura feita com o método Americano para o alvo masculino, a qual apresentou mediana 3. Na segunda fase, reconstruções faciais para quatro alvos (dois homens e duas mulheres) foram obtidas com o método Americano, considerando as quatro tabelas de espessuras de tecidos moles para brasileiros. Dezesseis reconstruções foram avaliadas por cento e vinte indivíduos, também pelos testes de reconhecimento e semelhança. Assim como na fase I, foram considerados o sexo e o grupo dos avaliadores. Para o alvo 1, as proporções de acertos são significativamente maiores para reconstruções feitas com as tabelas de cadáveres (44% e 38%) em relação às com os dados de exames de imagem. Para o alvo 4, as proporções de acertos com os dados de cadáveres (Tedeschi-Oliveira et al.) e com os de ressonância magnética foram significativamente maiores comparados às reconstruções com dados de tomografias computadorizadas. Em relação à semelhança, somente o alvo 1 mostrou diferenças significativas de frequências de semelhança leve entre reconstruções. Além disso, não houve influência nem do sexo, nem do conhecimento de anatomia nas frequências de reconhecimentos corretos. Espera-se que a tabela proposta possa ser empregada para a população brasileira.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the main technical difficulties in the fabrication of optical antennas working as light detectors is the proper design and manufacture of auxiliary elements as load lines and signal extraction structures. These elements need to be quite small to reach the location of the antennas and should have a minimal effect on the response of the device. Unfortunately this is not an easy task and signal extraction lines resonate along with the antenna producing a complex signal that usually masks the one given by the antenna. In order to decouple the resonance from the transduction we present in this contribution a parametric analysis of the response of a bolometric stripe that is surrounded by resonant dipoles with different geometries and orientations. We have checked that these elements should provide a signal proportional to the polarization state of the incoming light.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present some of the first science data with the new Keck/MOSFIRE instrument to test the effectiveness of different AGN/SF diagnostics at z ~ 1.5. MOSFIRE spectra were obtained in three H-band multi-slit masks in the GOODS-S field, resulting in 2 hr exposures of 36 emission-line galaxies. We compare X-ray data with the traditional emission-line ratio diagnostics and the alternative mass-excitation and color-excitation diagrams, combining new MOSFIRE infrared data with previous HST/WFC3 infrared spectra (from the 3D-HST survey) and multiwavelength photometry. We demonstrate that a high [O III]/Hβ ratio is insufficient as an active galactic nucleus (AGN) indicator at z > 1. For the four X-ray-detected galaxies, the classic diagnostics ([O III]/Hβ versus [N II]/Hα and [S II]/Hα) remain consistent with X-ray AGN/SF classification. The X-ray data also suggest that "composite" galaxies (with intermediate AGN/SF classification) host bona fide AGNs. Nearly ~2/3 of the z ~ 1.5 emission-line galaxies have nuclear activity detected by either X-rays or the classic diagnostics. Compared to the X-ray and line ratio classifications, the mass-excitation method remains effective at z > 1, but we show that the color-excitation method requires a new calibration to successfully identify AGNs at these redshifts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O estudo do movimento pulmonar é assunto de grande interesse na área médica. A observação direta do mesmo é inviável, uma vez que o pulmão colapsa quando a caixa torácica é aberta. Dentre os meios de observação indireta, escolheu-se o imageamento por ressonância magnética em respiração livre e sem uso de nenhum gás para melhorar o contraste ou qualquer informação de sincronismo. Esta escolha propõe diversos desafios, como: a superar a alta variação na qualidade das imagens, que é baixa, em geral, e a suscetibilidade a artefatos, entre outras limitações a serem superadas. Imagens de Tomografia Computadorizada apresentam melhor qualidade e menor tempo de aquisição, mas expõem o paciente a níveis consideráveis de radiação ionizante. É apresentada uma metodologia para segmentação do pulmão, produzindo um conjunto de pontos coordenados. Isto é feito através do processamento temporal da sequência de imagens de RM. Este processamento consiste nas seguintes etapas: geração de imagens temporais (2DSTI), transformada de Hough modificada, algoritmo de contornos ativos e geração de silhueta. A partir de um dado ponto, denominado centro de rotação, são geradas diversas imagens temporais com orientações variadas. É proposta uma formulação modificada da transformada de Hough para determinar curvas parametrizadas que sejam síncronas ao movimento diafragmático, chamados movimentos respiratórios. Também são utilizadas máscaras para delimitar o domínio de aplicação da transformada de Hough. São obtidos movimentos respiratórios que são suavizados pelo algoritmo de contornos ativos e, assim, permitem a geração de contornos para cada quadro pertencente a sequência e, portanto, de uma silhueta do pulmão para cada sequência.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copyright held by the author. DU faculty and students may access digitized MRPs by logging in with their DU ID in the Library's Catalog. Those not affiliated with DU may request digitized or microfilmed MRPs through interlibrary loan. Hard copies of MRPs are available to use by appointment in the Art Office in the Shwayder Art Building on campus.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"This paper will explore an unstudied fifteenth-century English alabaster altarpiece referred to as the Martyrdom Altarpiece. Based on dated and current scholarship, this analysis postulates two scenarios of the object's history. The first scenario postulates the Martyrdom Altarpiece as being commissioned by the Carthusian order. This position is based on stylistic and iconographic readings of the object that correlate with Carthusian analogs. These interpretations are strengthened by documentation sold with the Martyrdom Altarpiece during its 1978 auction sale. Scenario two argues that the Martyrdom Altarpiece's origins are not Carthusian, furthermore suggesting that the object is a composite or truncated piece"