926 resultados para MASS ANALYZED LON KINETIC ENERGY SPECTROMETRY(MIKES)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The ratios R-k1 of k-fold to single ionization of the target atom with simultaneous one-electron capture by the projectile have been measured for 15-480 keV/u (nu(p) = 0.8-4.4 a.u.) collisions of Cq+, Oq+ (q=1-4) with Ar, using time-of-flight techniques which allowed the simultaneous identification of the final charge state of both the low-velocity recoil ion and the high-velocity projectile for each collision event. The present ratios are similar to those for He+ and He2+ ion impact. The energy dependence of R-k1 shows a maximum at a certain energy, E-max. which approximately conforms to the q(1/2)-dependence scaling. For a fixed projectile state, the ratios R-k1 also vary strongly with outgoing reaction channels. The general behavior of the measured data can be qualitatively analyzed by a simple impact-parameter, independent-electron model. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relative isobaric yields of fragments produced in a series of heavy-ion-induced multifragmentation reactions have been analyzed in the framework of a modified Fisher model, primarily to determine the ratio of the symmetry energy coefficient to the temperature, a(sym)/T, as a function of fragment mass A. The extracted values increase from 5 to similar to 16 as A increases from 9 to 37. These values have been compared to the results of calculations using the antisymmetrized molecular dynamics (AMD) model together with the statistical decay code GEMINI. The calculated ratios are in good agreement with those extracted from the experiment. In contrast, the values extracted from the ratios of the primary isobars from the AMD model calculation are similar to 4 to 5 and show little variation with A. This observation indicates that the value of the symmetry energy coefficient derived from final fragment observables may be significantly different than the actual value at the time of fragment formation. The experimentally observed pairing effect is also studied within the same simulations. The Coulomb coefficient is also discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present the multiplicity and pseudorapidity distributions of photons produced in Au + Au and Cu + Cu collisions at root(NN)-N-s = 62.4 and 200 GeV. The photons are measured in the region -3.7 < eta < -2.3 using the photon Multiplicity detector in the STAR experiment at RHIC. The number of photons produced per average number of participating nucleon pairs increases with the beam energy and is independent of (lie collision centrality. For collisions with similar average numbers of participating nucleons the photon multiplicities are observed to be similar for An + Au and Cu + Cu collisions at a given beam energy. The ratios of the number of charged particles to photons in the measured pseudorapidity range are found to be 1.4 +/- 0.1 and 1.2 +/- 0.1 for root(NN)-N-s = 62.4 and 200 GeV, respectively. The energy dependence of this ratio could reflect varying contributions from baryons to charged particles, while mesons are the dominant contributors to photon production in the given kinematic region. The photon pseudorapidity distributions normalized by average number of participating nucleon pairs, when plotted as a function of eta-Y-beam, are found to follow a longitudinal scaling independent of centrality and colliding ion species at both beam energies. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Gas chromatography-mass spectrometry with electron ionization and positive-ion chemical ionization and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOF-MS) were applied for the characterization of the chemical composition of complex hydrocarbons in the non-polar neutral fraction of cigarette smoke condensates. Automated data processing by TOF-MS software combined with structured chromatograms and manual review of library hits were used to assign the components from GC x GC-TOF-MS analysis. The distributions of aliphatic hydrocarbons and aromatics were also investigated. Over 100 isoprenoid hydrocarbons were detected, including carotene degradation products, phytadiene isomers and carbocyclic diterpenoids. A total of 1800 hydrocarbons were tentatively identified, including aliphatic hydrocarbons, aromatics, and isoprenoid hydrocarbons. The identified hydrocarbons by GC x GC-TOF-MS were far more than those by GC-MS. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The applicability of on-line coupling of reversed-phase high-performance liquid chromatography to atmospheric pressure ionization tandem mass spectrometry for the separation and characterization of hop acids mixture from the crude extract of Humulus lupulus was investigated. The solvent system consisting of acetonitrile-aqueous formic acid was used to give proper separation of the six main hop bitter acids within 30 min. Further structural information about the components was acquired by collision-induced dissociation (CID). On the basis of analyses of the fragmentation patterns of the major alpha- and beta-bitter acids respectively, identification of the minor ones was performed using selected reaction monitoring (SRM) with a group of qualitatively relevant selected precursor-product ion transitions for each bitter acid in a single high performance liquid chromatography (HPLC) run. Using this technique, six minor hop acids, including "adprelupulone" observed for the first time in natural resources, were detected along with the six major acids. This hyphenated techniques provides potency for rapid qualitative determination of analogs and homologs in mixtures. (C) 2004 American Society for Mass Spectrometry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Since protein phosphorylation is a dominant mechanism of information transfer in cells, there is a great need for methods capable of accurately elucidating sites of phosphorylation. In recent years mass spectrometry has become an increasingly viable alternative to more traditional methods of phosphorylation analysis. The present study used immobilized metal affinity chromatography (IMAC coupled with a linear ion trap mass spectrometer to analyze phosphorylated proteins in mouse liver. A total of 26 peptide sequences defining 26 sites of phosphorylation were determined. Although this number of identified phosphoproteins is not large, the approach is still of interest because a series of conservative criteria were adopted in data analysis. We note that, although the binding of non-phosphorylated peptides to the IMAC column was apparent, the improvements in high-speed scanning and quality of MS/MS spectra provided by the linear ion trap contributed to the phosphoprotein identification. Further analysis demonstrated that MS/MS/MS analysis was necessary to exclude the false-positive matches resulting from the MS/MS experiments, especially for multiphosphorylated peptides. The use of the linear ion trap considerably enabled exploitation of nanoflow-HPLC/MS/MS, and in addition MS/MS/MS has great potential in phosphoproteome research of relatively complex samples. Copyright (C) 2004 John Wiley Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A comprehensive two-dimensional liquid chromatographic separation system based on the combination of a CN column and an ODS column is developed for the separation of components in a traditional Chinese medicine (TCM) Rhizoma chuanxiong. Two columns are coupled by a two-position, eight-port valve equipped with two storage loops and controlled by a computer. The effluent is detected by both the diode array detector and atmospheric pressure chemical ionization (APCI) mass spectrometer. More than 52 components in the methanol extract of R. chuanxiong were resolved and 11 of them were preliminary identified according to their UV and mass spectra. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a matrix-free technique that allows for the direct desorption/ionization of low-molecular-weight compounds with little or no fragmentation of analytes. This technique has a relatively high tolerance for contaminants commonly found in biological samples. DIOS-MS has been applied to determine the activity of immobilized enzymes on the porous silicon surface. Enzyme activities were also monitored with the addition of a competitive inhibitor in the substrate solution. It is demonstrated that this method can be applied to the screening of enzyme inhibitors. Furthermore, a method for peptide mapping analysis by in situ digestion of proteins on the porous silicon surface modified by trypsin, combined with matrix-assisted laser desorption/ionization-time of flight-MS has been developed.