875 resultados para Linear Multi-step Formulae


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Book summary: In a constantly evolving context of performance management, accountability and risk assessment, police organisations and frontline police officers are required to pay careful attention to what has come to be known as ‘at risk people’, ‘vulnerable populations’ or ‘vulnerable people’. Vulnerable people have become a key focus of policy. Concurrently, there have been stronger demands on police, and a steep increase in police powers in relation to their interaction with vulnerable people. The premise of this protectionist and interventionist agenda is threefold: to protect the rights of vulnerable individuals proactively cater for their vulnerability within the justice system; and to secure police operations and protocols within strict guidelines. This collection unpacks ‘vulnerable people policing’ in theory and practice and guides the reader through the policing process as it is experienced by police officers, victims, offenders, witnesses and justice stakeholders. Each chapter features a single step of the policing process: from police recruit education through to custody, and the final transfer of vulnerable people to courts and sentencing. This edited collection provides analytical, theoretical and empirical insights on vulnerable people policing, and reflects on critical issues in a domain that is increasingly subject to speedy conversion from policy to practice, and heightened media and political scrutiny. It breaks down policing practices, operations and procedures that have vulnerable populations as a focus, bringing together original and innovative academic research and literature, practitioner experience and discussion of policy implications (from local and international perspectives). The particular nature of this collection highlights the multi-disciplinary nature of police work, sheds light on how specific, mandatory policies guide police officers steps in their interaction with vulnerable populations, and discusses the practicalities of police decision making at key points in this process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of pre-contoured fracture fixation implants (plates and nails) that correctly fit the anatomy of a patient utilises 3D models of long bones with accurate geometric representation. 3D data is usually available from computed tomography (CT) scans of human cadavers that generally represent the above 60 year old age group. Thus, despite the fact that half of the seriously injured population comes from the 30 year age group and below, virtually no data exists from these younger age groups to inform the design of implants that optimally fit patients from these groups. Hence, relevant bone data from these age groups is required. The current gold standard for acquiring such data–CT–involves ionising radiation and cannot be used to scan healthy human volunteers. Magnetic resonance imaging (MRI) has been shown to be a potential alternative in the previous studies conducted using small bones (tarsal bones) and parts of the long bones. However, in order to use MRI effectively for 3D reconstruction of human long bones, further validations using long bones and appropriate reference standards are required. Accurate reconstruction of 3D models from CT or MRI data sets requires an accurate image segmentation method. Currently available sophisticated segmentation methods involve complex programming and mathematics that researchers are not trained to perform. Therefore, an accurate but relatively simple segmentation method is required for segmentation of CT and MRI data. Furthermore, some of the limitations of 1.5T MRI such as very long scanning times and poor contrast in articular regions can potentially be reduced by using higher field 3T MRI imaging. However, a quantification of the signal to noise ratio (SNR) gain at the bone - soft tissue interface should be performed; this is not reported in the literature. As MRI scanning of long bones has very long scanning times, the acquired images are more prone to motion artefacts due to random movements of the subject‟s limbs. One of the artefacts observed is the step artefact that is believed to occur from the random movements of the volunteer during a scan. This needs to be corrected before the models can be used for implant design. As the first aim, this study investigated two segmentation methods: intensity thresholding and Canny edge detection as accurate but simple segmentation methods for segmentation of MRI and CT data. The second aim was to investigate the usability of MRI as a radiation free imaging alternative to CT for reconstruction of 3D models of long bones. The third aim was to use 3T MRI to improve the poor contrast in articular regions and long scanning times of current MRI. The fourth and final aim was to minimise the step artefact using 3D modelling techniques. The segmentation methods were investigated using CT scans of five ovine femora. The single level thresholding was performed using a visually selected threshold level to segment the complete femur. For multilevel thresholding, multiple threshold levels calculated from the threshold selection method were used for the proximal, diaphyseal and distal regions of the femur. Canny edge detection was used by delineating the outer and inner contour of 2D images and then combining them to generate the 3D model. Models generated from these methods were compared to the reference standard generated using the mechanical contact scans of the denuded bone. The second aim was achieved using CT and MRI scans of five ovine femora and segmenting them using the multilevel threshold method. A surface geometric comparison was conducted between CT based, MRI based and reference models. To quantitatively compare the 1.5T images to the 3T MRI images, the right lower limbs of five healthy volunteers were scanned using scanners from the same manufacturer. The images obtained using the identical protocols were compared by means of SNR and contrast to noise ratio (CNR) of muscle, bone marrow and bone. In order to correct the step artefact in the final 3D models, the step was simulated in five ovine femora scanned with a 3T MRI scanner. The step was corrected using the iterative closest point (ICP) algorithm based aligning method. The present study demonstrated that the multi-threshold approach in combination with the threshold selection method can generate 3D models from long bones with an average deviation of 0.18 mm. The same was 0.24 mm of the single threshold method. There was a significant statistical difference between the accuracy of models generated by the two methods. In comparison, the Canny edge detection method generated average deviation of 0.20 mm. MRI based models exhibited 0.23 mm average deviation in comparison to the 0.18 mm average deviation of CT based models. The differences were not statistically significant. 3T MRI improved the contrast in the bone–muscle interfaces of most anatomical regions of femora and tibiae, potentially improving the inaccuracies conferred by poor contrast of the articular regions. Using the robust ICP algorithm to align the 3D surfaces, the step artefact that occurred by the volunteer moving the leg was corrected, generating errors of 0.32 ± 0.02 mm when compared with the reference standard. The study concludes that magnetic resonance imaging, together with simple multilevel thresholding segmentation, is able to produce 3D models of long bones with accurate geometric representations. The method is, therefore, a potential alternative to the current gold standard CT imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Catheter ablation for atrial fibrillation (AF) is more efficacious than antiarrhythmic therapy. Post ablation recurrences reduce ablation effectiveness and are contributed by lesion discontinuity in the fibrotic linear ablation lesions. The anti-fibrotic role of statins in reducing AF is being assessed in current trials. By reducing the chronic pathological fibrosis that occurs in AF they may reduce AF. However if statins also have an effect on the acute therapeutic fibrosis of an ablation, this could exacerbate lesion discontinuity and AF recurrence. We tested the hypothesis that statins attenuate ablation lesion continuity in a recognised pig atrial linear ablation model. Aims: To assess whether Atorvastatin diminishes the bi-directional conduction block produced by a linear atrial ablation lesion. Methods: Sixteen pigs were randomised to statin (n=8) or placebo (n=8) with drug pre-treatment for 3 days and a further 4 weeks. At initial electrophysiological study (EPS1) 3D right atrium (RA) mapping and a vertical ablation linear lesion in the posterior RA with bidirectional conduction block were completed (Gepstein Circ 1999). Follow-up electrophysiological assessment (EPS2) at 28 days assessed bidirectional conduction block maintenance. Results: Data of 15/16 (statin=7) pigs were analysed. Mean lesion length was 3.7 ± 0.8cm with a mean of 17.9 ± 5.7 lesion applications. Bi-directional conduction block was confirmed in 15/15 pigs (100%) at EPS1 and EPS2. Conclusions: Atorvastatin did not affect ablation lesion continuity in this pig atrial linear ablation model. If patients are on long-term statins for AF reduction, periablation cessation is probably not necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical industries have brought Information Technology (IT) in their systems for both patients and medical staffs due to the numerous benefits of IT we experience at presently. Moreover, the Mobile healthcare (M-health) system has been developed as the first step of Ubiquitous Health Environment (UHE). With the mobility and multi-functions, M-health system will be able to provide more efficient and various services for both doctors and patients. Due to the invisible feature of mobile signals, hackers have easier access to hospital networks than wired network systems. This may result in several security incidents unless security protocols are well implemented. In this paper, user authentication and authorization procedures will applied as a featured component at each level of M-health systems inthe hospital environment. Accordingly, M-health system in the hospital will meet the optimal requirements as a countermeasure to its vulnerabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prevention and safety promotion programmes. Traditionally, in-depth investigations of crash risks are conducted using exposure controlled study or case-control methodology. However, these studies need either observational data for control cases or exogenous exposure data like vehicle-kilometres travel, entry flow or product of conflicting flow for a particular traffic location, or a traffic site. These data are not readily available and often require extensive data collection effort on a system-wide basis. Aim: The objective of this research is to propose an alternative methodology to investigate crash risks of a road user group in different circumstances using readily available traffic police crash data. Methods: This study employs a combination of a log-linear model and the quasi-induced exposure technique to estimate crash risks of a road user group. While the log-linear model reveals the significant interactions and thus the prevalence of crashes of a road user group under various sets of traffic, environmental and roadway factors, the quasi-induced exposure technique estimates relative exposure of that road user in the same set of explanatory variables. Therefore, the combination of these two techniques provides relative measures of crash risks under various influences of roadway, environmental and traffic conditions. The proposed methodology has been illustrated using Brisbane motorcycle crash data of five years. Results: Interpretations of results on different combination of interactive factors show that the poor conspicuity of motorcycles is a predominant cause of motorcycle crashes. Inability of other drivers to correctly judge the speed and distance of an oncoming motorcyclist is also evident in right-of-way violation motorcycle crashes at intersections. Discussion and Conclusions: The combination of a log-linear model and the induced exposure technique is a promising methodology and can be applied to better estimate crash risks of other road users. This study also highlights the importance of considering interaction effects to better understand hazardous situations. A further study on the comparison between the proposed methodology and case-control method would be useful.