943 resultados para LED light calibration system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The genus Actinocephalus comprises 25 species and is restricted to Brazil, occurring mainly in the Espinhaco Mountains of Minas Gerais and Bahia States. Previous anatomical studies have reported the occurrence of intracellular papillae in the Actinocephalus roots, without dealing with their ultrastructure and function. The purpose of this paper is to investigate the structure, the composition and the probable function of the intracellular papillae of Actinocephalus roots, based on light microscopy, transmission electron microscopy and histochemical tests. The intracellular papillae occurred in all root tissues, from the rhizodermis to the vascular cylinder; they presented different forms and sizes and, ultrastructurally, they corresponded to material deposited between the cell wall and the plasma membrane. The histochemical tests carried out were positive for cellulose, pectin and callose. The intracellular papillae are responses of the plant cells to the interaction with fungi. They work as a physical barrier restricting fungal penetration, and they may also favor the supply of water and nutrients to the plant, since they increase root absorption surface. This might explain why the species of Actinocephalus are among the tallest Eriocaulaceae despite their reduced radicular system and the nutritional deficiency of the soil in which they grow. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The transmission of light through translucent posts was observed, and the microhardness of light-cured cement used to secure these posts was evaluated at different depths. Methods: Fifteen single-rooted standard bovine teeth, 16 mm in size, were used. The root canals were prepared using #3 drills Light-Post (five teeth) and Aestheti Post (five teeth) systems (BISCO), with a working-length of 12 mm. In five teeth, translucent posts were cemented (Light-Post #2), while another five teeth received opaque posts (Aestheti Post #2). The roots were painted with black nail varnish to prevent the passage of light through the lateral walls of the roots. The root canals of all the specimens were treated with the All-Bond 2 adhesive system (BISCO) and cemented with light-cured cement (Enforce, Dentsply). All the roots were transversally cut to obtain six specimens 1.5 mm thick. Every two sections corresponded to a specific region of the root (cervical, middle, apical), making it possible to observe the cement microhardness at different levels. The groups (n=10) were defined as: G1: translucent post (TP)/cervical region; G2: TP/middle region; G3: TP/apical region; G4: Opaque post (OP)/cervical region; G5: OP/middle region; G6: PO/apical region. Five root canals were only filled with cement for use as a control (G7). Then, Vickers microhardness analyses were performed. Results: In G3, G5 and G6, the cement was not sufficiently hard to allow for microhardness analysis. When submitted to the ANOVA test, G1 (35.07), G2 (24.28) and G4 (28.64) presented no statistical differences. When the previous groups were compared to G7 (51.00) using the Kruskal-Wallis test, a statistical difference was found. Conclusion: Translucent posts allow cement polymerization up to the middle portion of the root.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We combine the D0 measurement of the width difference between the light and heavy B-s(0) mass eigenstates and of the CP-violating mixing phase determined from the time-dependent angular distributions in the B-s(0)-> J/psi phi decays along with the charge asymmetry in semileptonic decays also measured with the D0 detector. With the additional constraint from the world average of the flavor-specific B-s(0) lifetime, we obtain Delta Gamma(s)equivalent to(Gamma(L)-Gamma(H))=0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=0.70(-0.47)(+0.39) or Delta Gamma(s)=-0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=2.44(-0.39)(+0.47). The data sample corresponds to an integrated luminosity of 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron Collider.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a study of the decay B-s(0)-> J/psi phi. We obtain the CP-odd fraction in the final state at time zero R-perpendicular to = 0.16 +/- 0.10 (stat) +/- 0.02(syst), the average lifetime of the (B-s(0), (B) over bar (0)(s)) system, (tau) over bar (B-s(0)) = 1.39(-0.16)(+0.13)(stat)(-0.02)(+0.01)(syst) ps, and the relative width difference between the heavy and light mass eigen-states, Delta Gamma/(Gamma) over bar = (Gamma(L) - Gamma(H))/(Gamma) over bar = 0.24(-0.38)(+0.28)(stat)(-0.04)(+0.03)(syst). With the additional constraint from the world average of the B-s(0) lifetime measurements using semileptonic decays, we find (tau) over bar (B-s(0)) = 1.39 +/- 0.06 ps and Delta Gamma/(Gamma) over bar = 0.25(-0.15)(+0.14). For the ratio of the B-s(0) and B-0 lifetimes we obtain (tau) over bar (B-s(0))/tau(B-s(0)) = 0.91 +/- 0.09(stat) +/- 0.003(syst).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From an analysis of the decay B-s(0)-> J/psi phi, we obtain the width difference between the light and heavy mass eigenstates Delta Gamma equivalent to(Gamma(L)-Gamma(H))=0.17 +/- 0.09(stat)+/- 0.02(syst) ps(-1) and the CP-violating phase phi(s)=-0.79 +/- 0.56(stat)(-0.01)(+0.14)(syst). Under the hypothesis of no CP violation (phi(s)equivalent to 0), we obtain 1/Gamma=tau/(B-s(0))=1.52 +/- 0.08(stat)(-0.03)(+0.01)(syst) ps and Delta Gamma=0.12(-0.10)(+0.08)(stat)+/- 0.02(syst) ps(-1). The data sample corresponds to an integrated luminosity of about 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron collider. This is the first direct measurement of the CP-violating mixing phase in the B-s(0) system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We show that the light-front vacuum is not trivial, and the Fock space for positive energy quanta solutions is not complete. As an example of this non triviality we have calculated the electromagnetic current for scalar bosons in the background field method were the covariance is restored through considering the complete Fock space of solutions.In this work we construct the electromagnetic current operator for a system composed of two free bosons. The technique employed to deduce these operators is through the definition of global propagators in the light front when a background electromagnetic field acts on one of the particles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We compute an effective action for a composite Higgs boson formed by new fermions belonging to a general technicolor non-Abelian gauge theory, using a quite general expression for the fermionic self-energy that depends on a certain parameter (alpha), that defines the technicolor theory from the extreme walking behavior up to the one with a standard operator product expansion behavior. We discuss the values of the trilinear and quadrilinear scalar couplings. Our calculation spans all the possible physical possibilities for mass and couplings of the composite system. In the case of extreme walking technicolor theories we verify that it is possible to have a composite Higgs boson with a mass as light as the present experimental limit, contrary to the usual expectation of a heavy mass for the composite Higgs boson. In this case we obtain an upper limit for the Higgs boson mass, (M(H)<= O(700) GeV for SU(2)(TC)), and the experimental data on the Higgs boson mass constrain SU(N)(TC) technicolor gauge groups to be smaller than SU(10)(TC).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)