988 resultados para Job loss


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Many patients and healthcare professionals believe that work-related psychosocial stress, such as job strain, can make asthma worse, but this is not corroborated by empirical evidence. We investigated the associations between job strain and the incidence of severe asthma exacerbations in working-age European men and women. Methods: We analysed individual-level data, collected between 1985 and 2010, from 102 175 working-age men and women in 11 prospective European studies. Job strain (a combination of high demands and low control at work) was self-reported at baseline. Incident severe asthma exacerbations were ascertained from national hospitalization and death registries. Associations between job strain and asthma exacerbations were modelled using Cox regression and the study-specific findings combined using random-effects meta-analyses. Results: During a median follow-up of 10 years, 1 109 individuals experienced a severe asthma exacerbation (430 with asthma as the primary diagnostic code). In the age- and sex-adjusted analyses, job strain was associated with an increased risk of severe asthma exacerbations defined using the primary diagnostic code (hazard ratio, HR: 1.27, 95% confidence interval, CI: 1.00, 1.61). This association attenuated towards the null after adjustment for potential confounders (HR: 1.22, 95% CI: 0.96, 1.55). No association was observed in the analyses with asthma defined using any diagnostic code (HR: 1.01, 95% CI: 0.86, 1.19). Conclusions: Our findings suggest that job strain is probably not an important risk factor for severe asthma exacerbations leading to hospitalization or death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal neurodegeneration is a key component of diabetic retinopathy (DR), although the detailed neuronal damage remains ill-defined. Recent evidence suggests that in addition to amacrine and ganglion cell, diabetes may also impact on other retinal neurons. In this study, we examined retinal degenerative changes in Ins2Akita diabetic mice. In scotopic electroretinograms (ERG), b-wave and oscillatory potentials were severely impaired in 9-month old Ins2Akita mice. Despite no obvious pathology in fundoscopic examination, optical coherence tomography (OCT) revealed a progressive thinning of the retina from 3 months onwards. Cone but not rod photoreceptor loss was observed in 3-month-old diabetic mice. Severe impairment of synaptic connectivity at the outer plexiform layer (OPL) was detected in 9-month old Ins2Akita mice. Specifically, photoreceptor presynaptic ribbons were reduced by 25% and postsynaptic boutons by 70%, although the density of horizontal, rod- and cone-bipolar cells remained similar to non-diabetic controls. Significant reductions in GABAergic and glycinergic amacrine cells and Brn3a+ retinal ganglion cells were also observed in 9-month old Ins2Akita mice. In conclusion, the Ins2Akita mouse develops cone photoreceptor degeneration and the impairment of synaptic connectivity at the OPL, predominately resulting from the loss of postsynaptic terminal boutons. Our findings suggest that the Ins2Akita mouse is a good model to study diabetic retinal neuropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between retention loss in single crystal PbTiO3 ferroelectric thin films and leakage currents is demonstrated by piezoresponse and conductive atomic force microscopy measurements. It was found that the polarization reversal in the absence of an electric field followed a stretched exponential behavior 1-exp[-(t/k)(d)] with exponent d>1, which is distinct from a dispersive random walk process with d <. The latter has been observed in polycrystalline films for which retention loss was associated with grain boundaries. The leakage current indicates power law scaling at short length scales, which strongly depends on the applied electric field. Additional information of the microstructure, which contributes to an explanation of the presence of leakage currents, is presented with high resolution transmission electron microscopy analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This special issue volume is concerned with how technology is changing the nature of work and working conditions while generating new products and new forms of service delivery. The five articles included in this volume cover service work, from the routine and clerical through to highly credentialed and professional work. Although some of the established challenges concerning the impact of Information and Communication Technology (ICT) on work and workplaces are evident in the articles, it is also clear that new service delivery processes demand new skills and training to some extent. Overall findings indicate that while ICT competencies are important, they need to be supplemented by the soft skills that are crucial for effective customer interactions and more open work systems with greater autonomy and participation whereby flexible work teams can have a positive impact on job quality outcomes. This introductory article examines technology and the changing nature of work through three strands of interpretation, prior to introducing the five articles in this special issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss-of-mains protection is an important component of the protection systems of embedded generation. The role of loss-of-mains is to disconnect the embedded generator from the utility grid in the event that connection to utility dispatched generation is lost. This is necessary for a number of reasons, including the safety of personnel during fault restoration and the protection of plant against out-of-synchronism reclosure to the mains supply. The incumbent methods of loss-of-mains protection were designed when the installed capacity of embedded generation was low, and known problems with nuisance tripping of the devices were considered acceptable because of the insignificant consequence to system operation. With the dramatic increase in the installed capacity of embedded generation over the last decade, the limitations of current islanding detection methods are no longer acceptable. This study describes a new method of loss-of-mains protection based on phasor measurement unit (PMU) technology, specifically using a low cost PMU device of the authors' design which has been developed for distribution network applications. The proposed method addresses the limitations of the incumbent methods, providing a solution that is free of nuisance tripping and has a zero non-detection zone. This system has been tested experimentally and is shown to be practical, feasible and effective. Threshold settings for the new method are recommended based on data acquired from both the Great Britain and Ireland power systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-energy electron-impact hydrogen loss due to dissociative electron attachment (DEA) to the uracil and thymine molecules in a water cluster environment is investigated theoretically. Only the A'-resonance contribution, describing the near-threshold behavior of DEA, is incorporated. Calculations are based on the nonlocal complex potential theory and the multiple scattering theory, and are performed for a model target with basic properties of uracil and thymine, surrounded by five water molecules. The DEA cross section is strongly enhanced when the attaching molecule is embedded in a water cluster. This growth is due to two effects: the increase of the resonance lifetime and the negative shift in the resonance position due to interaction of the intermediate negative ion with the surrounding water molecules. A similar effect was earlier found in DEA to chlorofluorocarbons. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method is presented for transmission loss allocation based on the separation of transmission loss caused by load and the loss due to circulating currents between generators. The theoretical basis for and derivation of the loss formulae are presented using simple systems. The concept is then extended to a general power system using the Ybus model. Details of the application of the proposed method to a typical power system are presented along with results from the IEEE 30 bus test system. The results from both the small system and the standard IEEE test system demonstrate the validity of the proposed method.

Relevância:

20.00% 20.00%

Publicador: