952 resultados para In-group


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study was aimed at assessing the changes in sperm motion patterns and the percentage of acrosome reaction (AR) in domestic cat semen after treatment with either ionomycin or progesterone (P(4)). Ten ejaculates were collected from five tomcats using an artificial vagina, and were diluted, centrifuged and resuspended in a capacitation medium. Samples were evaluated and divided into seven equal aliquots and, after 2 h at 25 degrees C, were incubated for 30 min at 38 degrees C in 5% CO(2) and then analyzed. Computer-assisted sperm analysis and a combination of three fluorescent probes were used to assess sperm plasma, acrosomal membrane integrity and mitochondrial transmembrane potential. Thirty minutes after the start of incubation, P(4) was added (10 mu g/ml) to the P1 group. Groups P2 and P3 were supplemented with P(4) (10 and 20 mu g/ml, respectively) only after 2 h of incubation, and groups I1 and I2 were supplemented with ionomycin (4 and 8 mu M, respectively) 2 h after incubation. Group E was supplemented with ethanol (0.6%) at 2 h after incubation and group C received no supplementation. Ionomycin and P(4) treatments led to a hyperactivation-like sperm motion and an increase (p < 0.05) in the percentage of AR. Although a higher (p < 0.05) percentage of AR was obtained in group I2 when compared with all P(4) groups, a decrease (p < 0.05) in total and progressive motility was observed in I2 group. As I1 group was similar to I2 to induce AR without diminishing sperm motility, we can conclude that ionomycin at 4 mu M seems to be more suitable to trigger AR in domestic cat sperm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to investigate the nutraceutic (Promater (R)) influence on semen, body weight, eritrogram and hormones testosterone and cortisol in Nelore young bulls. Twenty Nelore bulls were utilized, aging between 30 and 36 months, divided in group 1 (G1)= 10 (control) and group 2 (G2)= 10 (nutraceutic group - Promater (R): 20 mL/animal/day, during 70 days). Corporal weight, blood samples to eritrogram, testosterone and cortisol were obtained in days zero (D0), 35 (D35) and 70 (D70) in two groups. There was difference (P<0.01) among days collected (0, 35 and 70) with means of 424.30 kg, 480.70 kg and 502.60 kg, respectively, but there was not difference between groups. There was not difference among groups to semen, eritrogram, cortisol (G1 = 3,19 mu g/dL; G2 = 2,91 mu g/dL) and testosterone (G1 = 274,48 ng/dL; G2 = 509,65 ng/dL). The results exposed allow concluding that were not observed significative effect of the nutraceutic upon evaluated parameters: body weight, semen, hormonal profile and eritrogram.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Toxoplasma gondii isolates from Brazil are biologically and genetically different from European and North America isolates. Recently, four genotypes were considered the common clonal lineages in Brazil and were designated as types BrI, BrII, BrIII, and BrIV. The pathogenicity of two major Brazilian lineages was investigated after oral inoculation of queens in the middle third of their pregnancies with T. gondii cysts. Twelve pregnant queens without T. gondii antibodies were distributed in group A (infected with a type BrI isolate); group 2 (infected with type BrIII isolate), and group 3 (non-infected control). Infection with type BrI isolate caused toxoplasmosis manifestations and abortion from one litter. Toxoplasmosis manifestations besides premature stillbirth of one litter were observed in queens infected with type BrIII isolate. Indirect fluorescence antibody test showed T. gondii antibodies in all eight infected queens at 30 days after inoculation. In two 10-day-old kittens of the same litter (group 1), titers of 16 and 64 were detected. At the same time, titers of 16, 32, and 32 were detected in three kittens from the same litter (group 2). Experimental infection with tissue cysts from a type BrI and type BrIII isolates of T. gondii developed similar reproductive disturbance in primary infected pregnant queens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nesta pesquisa foram obtidos dados histológicos e morfométricos comparativos sobre os testículos de gatos, pós-orquiectomia, divididos em dois grupos: Grupo 1, gatos com até 1 ano de idade e Grupo 2, animais acima de 1 ano. Verificou-se que: (1) aos 4 meses de idade os túbulos seminíferos apresentaram-se pouco desenvolvidos e com ausência de luz, epitélio seminífero baixo, células de Sertoli indiferenciadas e tecido intersticial escasso; (2) aos 5 meses os túbulos seminíferos começaram a se diferenciar com aumento do diâmetro e luz tubulares e as demais estruturas permaneceram semelhantes à observação anterior; (3) aos 6-7 meses ocorreu o início da espermatogênese e espermiogênese; as células de Leydig apareceram maiores, poliédricas com citoplasma vacuolizado e núcleo claro, e tecido intersticial esparso com poucos vasos sangüíneos; (4) os animais com 1 ano de idade apresentaram morfologia testicular igual à do animal adulto, com túbulos seminíferos de maior diâmetro, epitélio germinativo alto e luz tubular pequena, as células de Leydig aparecendo poliédricas, com dimensões variadas, citoplasma vacuolizado, núcleo claro e nucléolo evidente, e espaço intertubular seminífero variado com vasos sanguíneos, predominantemente evidentes; (5) no Grupo 1 o diâmetro médio dos túbulos seminíferos foi de 160,58µm e no Grupo 2 foi de 185,94µm, sendo os valores médios significantes entre si; (6) a altura média do epitélio seminífero foi de 49,51µm para o Grupo 1 e de 63,29µm para o Grupo 2, estaticamente significantes; (7) os maiores valores mensurados foram obtidos para os gatos do Grupo 2, por serem gatos adultos e portanto com os órgãos reprodutores funcionais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implant-retention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 100, and 200 mu m, respectively. The crowns were attached by titanium retention screw with 30 N/cm to external hexagonal osseointegrated implants embedded in acrylic resin. After 2 min, the retention screw of each replica was submitted to detorque evaluation by an analogic torque gauge. Three retention screws were used to perform detorque evaluation at each replica and the procedure was repeated twice with each screw. Each group was submitted to 72 detorque measurements. Data were evaluated by ANOVA and Tukey test (P < 0.05). All groups exhibited significant decrease (P < 0.05) in preload and the lowest decrease occurred in Group A. Groups B, C, and D were statistically significant different from Group A (P < 0.05), but there was no statistically significant difference between Groups B and D (P > 0.05). Crowns with unilateral misfit presented higher preload decrease than crowns completely fitted to osseointegrated implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aims of this study were to analyze the histomorphology of developing permanent teeth whose primary teeth had suffered traumatic intrusion, as well as to compare the influence of immediate extraction of the intruded tooth to passive re-eruption. Nine dogs from 45 to 50 days old were submitted to the intrusion of the maxillary central and lateral primary incisors using a force applicator adapted to the teeth incisal cuspids. The right side intruded teeth were kept in their sockets and the ones on the left side were extracted 30 min later. After a postoperatory periods of 30 and 60 days, four (group 1) and five (group 2) dogs, respectively, were killed by perfusion. The histological evaluations showed that, in group 1, alterations had occurred in the odontoblastic layer and deposition of the enamel matrix had taken place in some specimens while in group 2, a portion of non-mineralized matrix was observed. We concluded that the morphological changes were because of the immediate trauma of intrusion. No differences were found between the groups where the primary tooth was immediately extracted or left to passively re-erupt.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It has been shown that the mineral trioxide aggregate (MTA) used to seal lateral/furcal perforations stimulates the deposition of newly formed cementum. Nevertheless, when the site of the perforation is contaminated, the healing process might occur under less favorable conditions. This study evaluated the repair healing process of noncontaminated and contaminated lateral perforations filled with MTA and the effect of previously filling the contaminated perforations with a bactericidal agent. Thirty lateral root perforations were prepared in endodontically treated dog's teeth, thus forming 3 groups with 10 specimens each. In group 1 the perforations were immediately sealed with MTA. In group 2 the perforations were left open for 7 days and thereafter sealed with MTA. In group 3 the perforations were left open for 7 days, filled temporarily with a calcium hydroxide-based paste for 14 days, and then sealed with MTA. The animals were killed after 90 days, and the pieces were prepared for histomorphologic and histomicrobiologic evaluations. The statistical analysis showed that group 1 had significantly better repair than groups 2 (P <.05) and 3 (P <.05), which validates the superior results obtained when MTA was immediately used to seal root perforations. Groups 2 and 3 had statistically similar repair to each other (P >.05). There were a larger number of cases of complete or partial biologic seal in group 1 compared with the contaminated groups. It might be concluded that the lateral root perforations sealed with MTA after contamination presented worse repair than the noncontaminated, immediately sealed perforations. The temporary filling with a bactericidal agent (calcium hydroxide-based paste) did not improve the repair of perforations exposed to contamination, and the contaminated groups presented similar results to each other.