980 resultados para Immunoassay, Assay validation, Accuracy, recision, Hyperinsulinemia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microsatellite instability (MSI) occurs in 10-20% of colorectal tumours and is associated with good prognosis. Here we describe the development and validation of a genomic signature that identifies colorectal cancer patients with MSI caused by DNA mismatch repair deficiency with high accuracy. Microsatellite status for 276 stage II and III colorectal tumours has been determined. Full-genome expression data was used to identify genes that correlate with MSI status. A subset of these samples (n = 73) had sequencing data for 615 genes available. An MSI gene signature of 64 genes was developed and validated in two independent validation sets: the first consisting of frozen samples from 132 stage II patients; and the second consisting of FFPE samples from the PETACC-3 trial (n = 625). The 64-gene MSI signature identified MSI patients in the first validation set with a sensitivity of 90.3% and an overall accuracy of 84.8%, with an AUC of 0.942 (95% CI, 0.888-0.975). In the second validation, the signature also showed excellent performance, with a sensitivity 94.3% and an overall accuracy of 90.6%, with an AUC of 0.965 (95% CI, 0.943-0.988). Besides correct identification of MSI patients, the gene signature identified a group of MSI-like patients that were MSS by standard assessment but MSI by signature assessment. The MSI-signature could be linked to a deficient MMR phenotype, as both MSI and MSI-like patients showed a high mutation frequency (8.2% and 6.4% of 615 genes assayed, respectively) as compared to patients classified as MSS (1.6% mutation frequency). The MSI signature showed prognostic power in stage II patients (n = 215) with a hazard ratio of 0.252 (p = 0.0145). Patients with an MSI-like phenotype had also an improved survival when compared to MSS patients. The MSI signature was translated to a diagnostic microarray and technically and clinically validated in FFPE and frozen samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and -VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatus and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n=77) were fully scanned with a X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM presented better accuracy than UFOM and VCS2000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood sampling on filter paper is a current practice seroepidemiological studies by indirect fluorescent antibody test (IFAT). There is, however, scant comparative information about the use of bloodspot eluates for detection of malarial IgG antibodies simultaneously by IFAT and enzyme immunoassay (ELISA). Here we report data obtained by both serological methods done on 219 bloodspot eluate samples collected in a rural community in Brazilian Amazon Basin (Alto Paraíso, Ariquemes municipality) where malaria is endemic. Plasmodium falciparum and P. vivax thick smear antigens were used in the IFAT; a detergent-soluble P. falciparum antigen was prepared for ELISA. Substantial agreement of results (Kappa coefficient k = 0.686) was observed when P. falciparum antigen was used in both tests, and IFAT titers were found to be strongly correlated ELISA antibody units (Spearman correlation coeficient rs = 0.818, p < 0.0001). Only moderate agreement (k = 0.467) between IFAT with P. vivax antigen and ELISA with P. falciparum antigen was observed. Spearman correlation coefficient value between quantitative results (IFAT titers and ELISA antibody units) in this case was numerically lowe (rs = 0.540, p < 0.0001). Our results suggest that, with P. falciparum antigen, both IFAT and ELISA performed on bloodspot eluates are equivalent for seropidemiological purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The few studies already published about phagocyte functions in Chediak-Higashi syndrome (CHS) has stated that neutrophils present slow rate of bacterial killing but normally ingest microorganisms. In the present study, both phagocytosis and killing of Staphylococcus aureus were verified to be in neutrophils from two patients with CHS when these functions were simultaneously evaluated by a fluorochrome phagocytosis assay. Electron microscopic examination showed morphologic differences among neutophils from CHS patients and normal neutrophils regarding the cytoplasmic structures and the aspects of the phagolysosomes. It was noteworthy the presence of giant phagolysosomes enclosing bacteria in active proliferation commonly observed in CHS neutrophils after 45 min of phagocytosis, wich corresponded with the impaired bactericidal activity of these leukocytes. The present results suggest that phagocytosis may also be defective in CHS, and point out to the sensitivity of the fluorochrome phagocytosis assay and its application in clinical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI) community. This paper evaluates and compares 20 algorithms for recovering the local intra-voxel fiber structure from diffusion MRI data and is based on the results of the "HARDI reconstruction challenge" organized in the context of the "ISBI 2012" conference. Evaluated methods encompass a mixture of classical techniques well known in the literature such as diffusion tensor, Q-Ball and diffusion spectrum imaging, algorithms inspired by the recent theory of compressed sensing and also brand new approaches proposed for the first time at this contest. To quantitatively compare the methods under controlled conditions, two datasets with known ground-truth were synthetically generated and two main criteria were used to evaluate the quality of the reconstructions in every voxel: correct assessment of the number of fiber populations and angular accuracy in their orientation. This comparative study investigates the behavior of every algorithm with varying experimental conditions and highlights strengths and weaknesses of each approach. This information can be useful not only for enhancing current algorithms and develop the next generation of reconstruction methods, but also to assist physicians in the choice of the most adequate technique for their studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The WHO criterion of defering any donation of blood by a confirmed case of malaria for three years after cessation of therapy can not be applied in areas where malaria in endemic. For this reason we developed an immunoenzymatic assay for the detection of plasmodial antigens for blood screening in malararial endemic areas. So, we tested sera from 191 individuals. Among patients with active disease 100% of the cases of Plasmodium falciparum or mixed infections and 91.7% of those with P. vivax were positive for the presence of plasmodial antigens. The lower parasitaemia detected was 0.0003% for P. vivax malária. When the frequency of positive circulating malarial antigens was evaluated among asymptomatic and symptomatic individuals with negative TBS, positive results were found in respectively 38.7% and 17.7% of the individuals studied in the 30 days after confirmed malaria attack. Data provide by these assays have shown that ELISA seemed to be more sensitive than parasitological examination for malaria diagnosis. This test by virtue of its high sensivity and the facilities in processing a large number of specimens, can prove to be useful in endemic areas for the recognition of asymptomatic malaria and screening of blood donors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Career adapt-ability has recently gained momentum as a psychosocial construct that not only has much to offer the field of career development, but also contributes to positive coping, adjustment and self-regulation through the four dimensions of concern, control, curiosity and confidence. The positive psychology movement, with concepts such as the orientations to happiness, explores the factors that contribute to human flourishing and optimum functioning. This research has two main contributions; 1) to validate a German version of the Career Adapt-Abilities Scale (CAAS), and 2) to extend the contribution of adapt-abilities to the field of work stress and explore its mediating capacity in the relation between orientations to happiness and work stress. We used a representative sample of the German-speaking Swiss working population including 1204 participants (49.8% women), aged between 26 and 56 (Mage = 42.04). Results indicated that the German version of the CAAS is valid, with overall high levels of model fit suggesting that the conceptual structure of career adapt-ability replicates well in this cultural context. Adapt-abilities showed a negative relationship to work stress, and a positive one with orientations to happiness. The engagement and pleasure scales of orientations to happiness also correlated negatively with work stress. Moreover, career adapt-ability mediates the relationship between orientations to happiness and work stress. In depth analysis of the mediating effect revealed that control is the only significant mediator. Thus control may be acting as a mechanism through which individuals attain their desired life at work subsequently contributing to reduced stress levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La dépression majeure est fréquente chez les patients qui consultent un cabinet de médecine générale. Elle reste toutefois difficile à diagnostiquer car elle est souvent masquée par une ou plusieurs plaintes physiques qui sont l'unique motif de consultation. Pour aider le médecin généraliste à démasquer ce trouble, un test de dépistage composé de deux questions a été développé et validé. Ce test indique une probabilité accrue de dépression si le patient répond positivement à au moins une des deux questions suivantes : « Est-ce que, durant le mois qui a précédé, vous vous êtes senti(e) triste, déprimé(e), désespéré(e) ? » et « Durant le mois qui a précédé, avez-vous ressenti un manque d'intérêt et de plaisir dans la plupart des activités que d'habitude vous appréciez ? ». Une troisième question, ajoutée aux deux questions ci-dessus, a été proposée récemment afin d'améliorer les performances de ce test de dépistage. Cette troisième question rend le test négatif si le patient répond négativement à la question suivante : « Souhaitez-vous de l'aide pour cela ? ». Une étude avait indiqué que l'ajout de la question supplémentaire améliorait la spécificité du test sans réduire sa sensibilité. Objectifs Il s'agissait de décrire la performance de deux tests de dépistage de la dépression majeure, composés, respectivement, de deux et de trois questions, dans une population de patients consultant dans un cabinet de médecine générale pour une plainte physique, et de les valider. Méthode Les réponses aux questions des tests de dépistage de la dépression dans la population de la cohorte SODA (Somatisation, Depression, Anxiety) ont été utilisées. Il s'agissait de patients de plus de 18 ans, sélectionnés aléatoirement, consultant pour au moins une plainte physique auprès de 24 médecins généralistes de Suisse Romande, réexaminés une année après l'inclusion dans la cohorte. Le questionnaire validé « Full Patient Health Questionnaire » a été utilisé, le même jour, pour diagnostiquer une dépression majeure. Ce résultat a été utilisé pour évaluer les performances des deux tests de dépistage en calculant la sensibilité et la spécificité, notamment. Résultats Les données de 724 / 937 patients inclus ont pu être utilisées. Un diagnostic de dépression majeure a été posé chez 9.5% des patients (n = 69). La sensibilité et la spécificité des deux questions de dépistage étaient de 91.3% (IC95% : 81.4-96.4%) et 65.0% (IC95% : 61.2-68.6%), respectivement. En ajoutant la troisième question, la sensibilité des deux questions de dépistage a diminué à 59.4% (IC95% : 47.0-70.9%) et la spécificité a augmenté à 88.2% (IC95% : 85.4-90.5%). Conclusions L'utilisation des deux questions pour le dépistage de la dépression majeure est associée à une haute sensibilité et à une basse spécificité chez des patients se présentant en cabinet de médecine générale pour une plainte physique. En ajoutant la troisième question, la spécificité augmente, mais la sensibilité diminue. Ainsi, en ajoutant la troisième question, quatre patients dépressifs majeurs sur dix ne sont pas détectés, alors que seulement un patient sur dix n'est pas détecté avec les deux questions de dépistage. Notre étude montre que le test composé de deux questions reste une méthode de choix pour le dépistage de la dépression majeure et que l'ajout de la troisième question n'est pas recommandée. Celle-ci reste toutefois pertinente dans l'incitation au dialogue sur le sujet de la dépression entre le médecin et son patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schistosomiasis in Americawith the exception of Brazil, behaves as a chronic mild disease with few clinical manifestations due to low parasite burden. These features restrict the clinical and parasitological diagnosis. The most commonly used stool examination method, Kato-Katz, becomes intensitive when the majority of individuals excrete less than 100 eggs/g of feces. In view that antigen-detecting techniques have not been able to reveal light infections, the antibody detecting assays remain as a very valuable diagnostic tool for epidemiological surveillance. The Venezuelan Schistosomiasis Research group (CECOICE) has designed a mass chemotherapy strategy based on sero-diagnosis. Since blood sampling is one of the important limitating factors for large seroepidemiological trials we developed a simple capillary technique that sucessfully overcomed most of the limitations of blood drawing. In this sense, ELISA seems to be the most adecuate test for epidemiological studies. Soluble egg Schistosoma mansoni antigen (SEA) has been largely used in Venezuela. The sensitivity ELISA-SEA in our hands is 90% moreover its specific reach 92% when populations from non-endemic areas but heavily infected with other intestinal parasites are analyzed. The Schistosomiasis Control Program is currently carrying out the surveillance of endemic areas using ELISA-SEA as the first screening method, followed by the Circumoval Precipitin test for validation assay. The results with these two serological techniques allowed us to defined the criteria of chemotherapy in populations of the endemic areas. On the search of better diagnostic technique, Alkaline Phosphatase Immunoenzyme Assay (APIA) is being evaluated in field surveys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot enzyme linked immunosorbent assay (dot-ELISA) was previously developed to detect specific antibodies in rabbits sera immunized against FIA protein obtained from Yersina pestis. This antigen was covalently linked onto the surface of dacron (polyethyleneterephthalate). Here, standard conditions are described for the optimization of this procedure: an amount of 20 ng of FIA protein was fixed onto dacron; anti-rabbit IgG peroxidase conjugate diluted 1:8,000 and 30% non-fat instant milk as blocking substance were used throughout the method. This procedure was compared with that employing nitrocellulose as solid-phase which showed to be more sensitive. However, the method based on dacron did not show false positive reactions against non-immunized rabbits sera at low antigen amount and diluted anti-IgG peroxidase conjugate.