926 resultados para Hydraulic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The coatings mortars are essential elements of building structures because they execute an important role in protecting walls and are particularly exposed to aggressive action responsible for its degradation over time. The importance of wall coverings has been the subject of discussion and analysis in the conservation and rehabilitation of old buildings. Are sometimes removed and replaced with inappropriate solutions of constructive point of view or architecture. The most commonly used coatings on walls of old buildings is based on traditional hydraulic lime mortars. The present study aims at the formulation of new lime- based mortars and aerial fine aggregate, in order to contribute to a better field of conservation and restoration mortar coating of old buildings. Residue was used for polishing porcelain as fine aggregate, replacing the aggregate (sand), in percentages 05-30% by mass. We conducted a thorough evaluation of the mortar properties in fresh and hardened state by comparing the performance of the same with a reference mortar. The residue used was characterized as the density, bulk density, and particle size laser, scanning electron microscopy, X-ray diffraction and X-ray fluorescence. Formulations were produced 7, 6 with residue and one commonly used formulation, which served as a reference. In the formulations of lime mortars air (hydrated lime powder CH-I) has been adopted a stroke volume (1:3) with constant binder, was varied and the water / binder and aggregate and waste. For evaluation of mortars fresh, proceeded to consistency analysis, specific gravity, water retention and air content embedded. In the hardened state assays were performed in specific gravity, water retention, modulus of elasticity, tensile strength in bending, compressive strength, water absorption by capillary action, adhesion, tensile strength, resistance to shrinkage and salts by of crystallization trials with resources chloride solution, nitrate and sulfate all sodium in prismatic at 90 days of age, in addition to the micro structural analysis of mortars. Based on the results we can see that the mortar formulated with 10% content of waste and the reference free retraction feature more stable closer to neutrality. The composition of 10% was obtained better performance against the action of the salt crystallization. The mortar with 15% residue obtained better density, lower air content embedded and high capacity for water retention developing good workability. The replacement of 20% of waste generates a satisfactory utilization of resistance to compression, flexion and traction grip the base. And, finally, it can be seen that the mortar with 10, 15 and 20% residual show, in principle, good suitability as coatings, thus enabling a final result consistent with durability, workability and aesthetics developing therefore a material with better performance to repair or replace existing mortars in old buildings

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The primary cementing is an important step in the oilwell drilling process, ensuring the mechanical stability of the well and the hydraulic isolation between casing and formation. For slurries to meet the requirements for application in a certain well, some care in the project should be taken into account to obtain a cement paste with the proper composition. In most cases, it is necessary to add chemicals to the cement to modify its properties, according to the operation conditions and thus obtain slurries that can move inside the jacket providing a good displacement to the interest area. New technologies of preparation and use of chemicals and modernization of technological standards in the construction industry have resulted in the development of new chemical additives for optimizing the properties of building materials. Products such as polycarboxylate superplasticizers provide improved fluidity and cohesion of the cement grains, in addition to improving the dispersion with respect to slurries without additives. This study aimed at adapting chemical additives used in civil construction to be used use in oilwell cement slurries systems, using Portland cement CPP-Special Class as the hydraulic binder. The chemical additives classified as defoamer, dispersant, fluid loss controller and retarder were characterized by infrared absorption spectroscopy, thermogravimetric analyses and technological tests set by the API (American Petroleum Institute). These additives showed satisfactory results for its application in cement slurries systems for oil wells. The silicone-based defoamer promoted the reduction of air bubbles incorporated during the stirring of the slurries. The dispersant significantly reduced the rheological parameters of the systems studied. The tests performed with the fluid loss controller and the retarder also resulted in suitable properties for application as chemical additives in cement slurries

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although there are a wide variety of additives that act in fresh state, to adjust the properties of cement, there is also a search by additions that improve the tenacity of the cement in the hardened state. This, in turn, can often be increased by inserting fibers, which act on the deflection of microcracks. This study aimed to use a microfiber glass wool (silica-based) as an additive reinforcing the cement matrix, improving the rupture tenacity, in order to prevent the propagation of microcracks in the cement sheath commonly found in oil wells submitted to high temperatures. The fibers were added at different concentrations, 2 to 5% (BWOC) and varied average sizes, grinding for 90 s, 180 s, 300 s, 600 s. The cement slurries were made with a density of 1,90 g/ cm3 (15,6 lb/gal), using Portland cement CPP- Special Class as the hydraulic binder and 40% silica flour. The characterization of the fiber was made by scanning electron microscopy (SEM), particle size by sieving, X-ray fluorescence (XRF), X-ray diffraction (XRD) and thermogravimetry (TG / DTG). Were performed technological tests set by the API (American Petroleum Institute) by rheology, stability, free water, compressive strength, as well as testing rupture energy, elastic modulus and permeability. The characterization results showed good thermal stability of the microfiber glass wool for application in oil wells submitted to steam injection and, also, that from the particle size data, it was possible to suggest that microfibers milled up to 300 s, are ideal to act as reinforcement to the cement slurries. The rheological parameters, there was committal of plastic viscosity when larger lengths were inserted of microfiber (F90). The values obtained by free water and stability were presented according to API. The mechanical properties, the incorporation of microfiber to the cement slurries gave better rupture tenacity, as compared to reference cement slurries. The values of compressive strength, elastic modulus and permeability have been maintained with respect to the reference cement slurries. Thus, cement slurries reinforced with microfiber glass wool can ensure good application for cementing oil wells submitted to steam injection, which requires control of microcracks, due to the thermal gradients

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cementing operation is one of the most important stages in the oil well drilling processes and has main function to form hydraulic seal between the various permeable zones traversed by the well. However, several problems may occur with the cement sheath, either during primary cementing or during the well production period. Cements low resistance can cause fissures in the cement sheath and compromise the mechanical integrity of the annular, resulting in contamination of groundwater and producing zones. Several researches show that biomass ash, in particular, those generated by the sugarcane industry have pozzolanic activity and can be added in the composition of the cementing slurries in diverse applications, providing improvements in mechanical properties, revenue and cement durability. Due to the importance of a low cost additive that increases the mechanical properties in a well cementing operations, this study aimed to potentiate the use of sugarcane bagasse ash as pozzolanic material, evaluate the mechanisms of action of this one on cement pastes properties and apply this material in systems slurries aimed to cementing a well with 800 m depth and geothermal gradient of 1.7 °F/100 ft, as much primary cementing operations as squeeze. To do this, the ash beneficiation methods were realized through the processes of grinding, sifting and reburning (calcination) and then characterization by X-ray fluorescence, XRD, TG / DTG, specific surface area, particle size distribution by laser diffraction and mass specific. Moreover, the ash pozzolanic activity added to the cement at concentrations of 0%, 20% and 40% BWOC was evaluated by pozzolanic activity index with lime and with Portland cement. The evaluation of the pozzolanic activity by XRD, TG / DTG and compressive strength confirmed the ash reactivity and indicated that the addition of 20% in the composition of cement slurries produces improvement 34% in the mechanical properties of the slurry cured. Cement slurries properties evaluated by rheological measurements, fluid loss, free fluid, slurry sedimentation, thickening time and sonic strength (UCA) were satisfactory and showed the viability of using the sugarcane ash in cement slurries composition for well cementing

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increasing of energetic consumption in the worldwile, conventional reservoirs, known by their easy exploration and exploitation, are not being enough to satisfy this demand, what has made necessary exploring unconventional reservoirs. This kind of exploration demands developing more advanced technologies to make possible to exploit those hydrocarbons. Tight gas is an example of this kind of unconventional reservoir. It refers to sandstone fields with low porosity, around 8%, and permeabilities between 0.1 and 0.0001 mD, which accumulates considerable amounts of natural gas. That natural gas can only be extracted by applying hydraulic fracturing, aiming at stimulating the reservoir, by creating a preferential way through the reservoir to the well, changing and making easier the flow of fluids, thus increasing the productivity of those reservoirs. Therefore, the objective of this thesis is analyzing the recovery factor of a reservoir by applying hydraulic fracturing. All the studies were performed through simulations using the IMEX software, by CMG (Computer Modelling Group), in it 2012.10 version

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increase hydrocarbons production is the main goal of the oilwell industry worldwide. Hydraulic fracturing is often applied to achieve this goal due to a combination of attractive aspects including easiness and low operational costs associated with fast and highly economical response. Conventional fracturing usually involves high-flowing high-pressure pumping of a viscous fluid responsible for opening the fracture in the hydrocarbon producing rock. The thickness of the fracture should be enough to assure the penetration of the particles of a solid proppant into the rock. The proppant is driven into the target formation by a carrier fluid. After pumping, all fluids are filtered through the faces of the fracture and penetrate the rock. The proppant remains in the fracture holding it open and assuring high hydraulic conductivity. The present study proposes a different approach for hydraulic fracturing. Fractures with infinity conductivity are formed and used to further improve the production of highly permeable formations as well as to produce long fractures in naturally fractured formations. Naturally open fractures with infinite conductivity are usually encountered. They can be observed in rock outcrops and core plugs, or noticed by the total loss of circulation during drilling (even with low density fluids), image profiles, pumping tests (Mini-Frac and Mini Fall Off), and injection tests below fracturing pressure, whose flow is higher than expected for radial Darcian ones. Naturally occurring fractures are kept open by randomly shaped and placed supporting points, able to hold the faces of the fracture separate even under typical closing pressures. The approach presented herein generates infinite conductivity canal held open by artificially created parallel supporting areas positioned both horizontally and vertically. The size of these areas is designed to hold the permeable zones open supported by the impermeable areas. The England & Green equation was used to theoretically prove that the fracture can be held open by such artificially created set of horizontal parallel supporting areas. To assess the benefits of fractures characterized by infinite conductivity, an overall comparison with finite conductivity fractures was carried out using a series of parameters including fracture pressure loss and dimensionless conductivity as a function of flow production, FOI folds of increase, flow production and cumulative production as a function of time, and finally plots of net present value and productivity index

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se avaliar a produção e a qualidade do biogás e do biofertilizante obtidos em biodigestores abastecidos com dejetos de suínos, nas fases inicial, crescimento e terminação, alimentados com dietas formuladas à base de milho ou sorgo. Foram utilizados 20 biodigestores de bancada, com tempo de retenção hidráulica de 30 dias, e cargas diárias que continham 4,0 a 6,0% de sólidos totais (ST) e 3,6 a 5,2% de sólidos voláteis (SV). Nos efluentes dos biodigestores, foram verificados teores médios de ST variando de 1,6 a 2,0% e de SV entre 1,2 e 1,6%. As reduções médias de ST foram de 57,7 a 64,7% e de SV de 61,7 a 69,0%, sendo que houve diferença somente na fase de terminação, na qual as maiores reduções médias foram para biodigestores abastecidos com dejetos de animais alimentados com dietas à base de milho. Nos biodigestores abastecidos com dejetos de animais em fase inicial e de crescimento, alimentados com dietas formuladas à base de milho, foram verificadas maiores produções médias de biogás e os maiores potenciais médios de produção de biogás. Os potenciais médios obtidos foram 0,033; 0,181; 0,685; 0,788 e 1,132 m³ por kg de afluente, estrume, ST adicionados, SV adicionados e SV reduzidos, respectivamente. Não foram verificadas diferenças quanto ao teor médio de metano no biogás entre dietas e fases. As concentrações médias dos nutrientes N, P, K, Ca, Mg, Na, Fe, Mn, Zn e Cu no afluente e efluente dos biodigestores variaram entre as dietas e fases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A maioria das instalações de abastecimento de água utiliza bombas hidráulicas do tipo turbobombas, requerendo que o interior de sua carcaça e da tubulação de sucção esteja preenchido com água (escorvados) para que a sucção da água possa ser efetivada. O escorvamento das bombas pode ser efetuado instalando-as abaixo do reservatório de captação (bomba afogada). Quando a bomba está acima do reservatório e o escorvamento é manual, é necessário usar válvulas-de-pé, que são suscetíveis ao mau funcionamento, limitando a confiabilidade do sistema, principalmente em caso de automação. Como alternativa à válvula-de-pé, neste trabalho, foram estudados dois tanques escorva, testados no Laboratório de Hidráulica e Irrigação da FCAV/UNESP - Jaboticabal, avaliando-se situações de altura manométrica de sucção de bomba centrífuga e relações entre volume útil do tanque e volume do tubo de sucção, tendo-se concluído: a) o volume do tanque de escorva é função do volume do tubo de sucção da instalação de bombeamento e da altura manométrica de sucção; b) o volume do tanque de escorva pode ser calculado seguindo-se a Lei de Boyle, com percentagem de acréscimo que, neste estudo, foi de 10% para um modelo de tanque e de 30% para o segundo modelo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study aimed to evaluate the radial profile and the uniformity of water distribution of sprinkler manufactured by the company NaanDanJain, model 427 1/2 '' M and nozzle with 2.8 mm of internal diameter, operating at pressures of 150, 200, 300 and 400 kPa and five positions of the deflector (0, 20, 50, 80 and 100%). For the determination of the parameters evaluated, the grid method was used and with the help of computer application CATCH 3D, overlapping layers of water depths was calculated with ten spacing. The results show that the deflector adjustment influences the radius of wetness and the distribution profile while the uniformity of water application showed as an important mechanism, since it permits different behavior for the sprinkler, ensuring wide track of utilization of the equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El conocimiento de las características de las diferentes boquillas de pulverización tiene una importancia imprescindible para la adecuada y correcta recomendación de su uso. El objetivo de este trabajo fue determinar el espaciamiento máximo en la barra horizontal de pulverización, la simetría del chorro y el diámetro de gotas en boquillas de pulverización TF-VS2. El trabajo fue realizado en mesa de deposición, en donde fueron utilizadas las presiones de 100, 200 y 300 kPa en las alturas de trabajo de 40 y 50 cm. La simetría del chorro fue determinada en función de dos metodologías (empírica y trigonométrica). También se determinó el tamaño de las gotas, utilizando el método de difracción de rayos laser, en función de dos caldos de pulverización constituidos por agua y por agua con adyuvante en las tres presiones de trabajo ya descritas. Los espaciamientos máximos entre las boquillas en la barra de pulverización no pueden rebasar los 70 y 82 cm, admitiéndose el CV de un 10% para las alturas de 40 y de 50 cm respectivamente. La mayor presión proporcionó el menor diámetro mediano volumétrico (DMV) y la peor uniformidad de gotas, además del mayor porcentaje de gotas susceptibles a deriva, así como también aumentó la simetría entre los chorros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho teve como objetivo avaliar a distribuição de calda por pontas de pulverização hidráulicas para a aplicação de herbicidas em pré-emergência das plantas daninhas, em função do espaçamento na barra utilizada em áreas de reflorestamento com eucalipto. O experimento foi realizado no Laboratório de Ciência das Plantas Daninhas do Departamento de Fitossanidade da UNESP, Câmpus de Jaboticabal. Foram utilizados os modelos com indução de ar AIUB 025, AI 110025, TTI 110015 e DB 12002, considerando o espaçamento de 0,8; 1,0; 1,2 e 1,5 m entre eles. A avaliação da distribuição da calda pulverizada foi realizada em mesa de deposição. Pulverizou-se água com 0,1% do adjuvante não iônico alquilfenol. Os valores observados foram utilizados para a obtenção das curvas de deposição e do coeficiente de variação. Para a sobreposição de dois exemplares de pontas, conclui-se que o modelo AIUB 025 possui menores coeficientes de variação, resultando em melhores características operacionais em relação à AI 110025, TTI 110015 e DB 12002. Para a utilização de três exemplares de pontas, seguindo somente o critério da distribuição da calda, a melhor combinação foi entre AIUB 025 e DB 12002, como intercalar. A utilização da ponta intercalar aumentou significativamente o consumo de calda.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was aimed to evaluate the spectrum and uniformity of droplets in function of sprayers, spraying volumes and rates of chemical insecticide on the mortality of Pseudoplusia includens in laboratory. The work was carried out at UNESP, Jaboticabal, SP, Brazil. The following treatments were applied over the caterpillars: two equipments (atomizer and hydraulic nozzle); two spray volumes (17 and 50 L ha(-1) for the atomizer and 50 and 100 L ha(-1) for the hydraulic nozzle); and two dosages of the insecticide endosulfan (0.5 and 1.0 L pc ha(-1)), in fully randomized plots, in a factorial scheme 2x2x2 and 1 untreated check. The caterpillars mortality was evaluated until the 6(th) day after the application of treatments. The spectrum of the droplets was evaluated in a particle size analyzer in real time determining the diameter and spectrum of droplets sprayed through the laser beam of the analyser. It was verified that the spray volume can be reduced by 17 L ha(-1) without losses on the P. includens control. The doses of 0.5 L pc ha(-1) (recommended for Anticarsia gemmatalis) did not satisfactorily control the caterpillar soybean looper. The atomizer produces droplets of higher uniformity (SPAN: 0.52) and lower percentage of droplets susceptible to drift (3.3%) compared to hydraulic nozzle (SPAN: 1.34 e % droplets <= 100 mu m: 15.2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em experimento de campo, avaliou-se o potencial de impacto ambiental de águas residuárias de suinocultura, acondicionadas em um tanque de estocagem, com distintos tempos de retenção hidráulica e aplicadas, posteriormente, em lisímetros preenchidos com solos arenosos, argilosos e de texturas médias. Para tal, foram determinados os valores de pH nos solos e as quantificações das concentrações de zinco e cobre na água residuária in natura e, após os quatro tempos de retenção hidráulica do tanque de estocagem, nos percolados dos lisímetros e nos solos. Os resultados mostram que a estocagem não foi eficiente na redução, aos níveis exigidos pela legislação, das concentrações de zinco e cobre nos efluentes do tanque de estocagem. A aplicação no solo gerou reduções eficientes nas concentrações de zinco e cobre. Por fim, enfocando a contribuição fertilizante destas águas residuárias, o solo argiloso foi o mais beneficiado com este sistema integrado de tratamento, contribuindo para a redução das concentrações de zinco e cobre para valores abaixo dos permitidos pelas legislações, o que protegeria o lençol freático da contaminação por esses dois metais pesados.