933 resultados para Hall Angle
Resumo:
PURPOSE: To report the results of a Latin American consensus panel regarding the diagnosis and management of primary open-angle glaucoma and to compare these results with those from a similar panel in the United States. DESIGN: A RAND-like (Research and Development) appropriateness methodology was used to assess glaucoma practice in Latin America. METHODS: The 148 polling statements created for the RAND-like analysis in the United States and 10 additional statements specific to glaucoma care in Latin America were presented to a panel of Latin American glaucoma experts. Panelists were polled in private using the RAND-like methodology before and after the panel meeting. RESULTS: Consensus agreement or disagreement among Latin American experts was reached for 51.3% of statements before the meeting and increased to 66.5% in the private, anonymous meeting after polling (79.0% agreement, 21.0% disagreement). Although there was a high degree of concordance (111 of 148 statements; 75%) between the results of this Latin American panel and the United States panel, there were some notable exceptions relating to diagnostic and therapeutic decision making. CONCLUSIONS: This RAND-like consensus methodology provides a perspective of how Latin American glaucoma practitioners view many aspects of glaucoma and compares these results with those obtained using a similar methodology from practitioners in the United States. These findings may be helpful to ophthalmologists providing glaucoma care in Latin America and in other regions of the world. (Am J Ophthalmol 2012;154: 460-465. (C) 2012 by Elsevier Inc. All rights reserved.)
Resumo:
An experimental study on Vortex-Induced Motion (VIM) of the semi-submersible platform concept with four square columns is presented. Model tests were carried out to check the influence of different headings and hull appendages (riser supports located at the pontoons; fairleads and the mooring stretches located vertically at the external column faces; and hard pipes located vertically at the internal column faces). The results comprise in-line, transverse and yaw motions, as well as combined motions in the XY plane, drag and lift forces and spectral analysis. The main results showed that VIM in the transverse direction occurred in a range of reduced velocity 4.0 up to 14.0 with amplitude peaks around reduced velocities around 7.0 and 8.0. The largest transverse amplitudes obtained were around 40% of the column width for 30 degrees and 45 degrees incidences. Another important result observed was a considerable yaw motion oscillation, in which a synchronization region could be identified as a resonance phenomenon. The largest yaw motions were verified for the 0 degrees incidence and the maxima amplitudes around 4.5 degrees. The hull appendages located at columns had the greatest influence on the VIM response of the semi-submersible. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The origin of the trigger-angle dependence of the ridge structure in two-hadron long-range correlations, as observed at RHIC, is discussed as due to an interplay between the elliptic flow caused by the initial state global geometry and flow produced by fluctuations.
Resumo:
The mechanism of forward angle incoherent photoproduction of pseudoscalar mesons off nuclei is revisited via the time-dependent multicollisional Monte Carlo (MCMC) intranuclear cascade model. Our results-combined with recent developments to address coherent photoproduction-reproduce with good accuracy recent JLab data of pi(0) photoproduction from carbon and lead at an average photon energy k similar to 5.2 GeV. For the case of. photoproduction, our results for k = 9 GeV suggest that future measurements to extract the eta ->gamma gamma decay width via the Primakoff method should be focused on light nuclei, where the disentanglement between the Coulomb and strong amplitudes is more easily achieved. The prospects to use heavy nuclei data to access the unknown eta N cross section in cold nuclear matter are also presented.
Resumo:
Polarized magnetophotoluminescence is employed to study the energies and occupancies of four lowest Landau levels in a couple quantum Hall GaAs/AlGaAs double quantum well. As a result, a magnetic field-induced redistribution of charge over the Landau levels manifesting to the continuous formation of the charge density wave and direct evidence for the symmetric-antisymmetric gap shrinkage at v = 3 are found. The observed interlayer charge exchange causes depolarization of the ferromagnetic ground state.
Resumo:
Proton nuclear magnetic resonance (H-1 NMR) spectroscopy for detection of biochemical changes in biological samples is a successful technique. However, the achieved NMR resolution is not sufficiently high when the analysis is performed with intact cells. To improve spectral resolution, high resolution magic angle spinning (HR-MAS) is used and the broad signals are separated by a T-2 filter based on the CPMG pulse sequence. Additionally, HR-MAS experiments with a T-2 filter are preceded by a water suppression procedure. The goal of this work is to demonstrate that the experimental procedures of water suppression and T-2 or diffusing filters are unnecessary steps when the filter diagonalization method (FDM) is used to process the time domain HR-MAS signals. Manipulation of the FDM results, represented as a tabular list of peak positions, widths, amplitudes and phases, allows the removal of water signals without the disturbing overlapping or nearby signals. Additionally, the FDM can also be used for phase correction and noise suppression, and to discriminate between sharp and broad lines. Results demonstrate the applicability of the FDM post-acquisition processing to obtain high quality HR-MAS spectra of heterogeneous biological materials.
Resumo:
Composites formed of a polymer-embedded layer of sub-10 nm gold nanoclusters were fabricated by very low energy (49 eV) gold ion implantation into polymethylmethacrylate. We used small angle x-ray scattering to investigate the structural properties of these metal-polymer composite layers that were fabricated at three different ion doses, both in their original form (as-implanted) and after annealing for 6 h well above the polymer glass transition temperature (150 degrees C). We show that annealing provides a simple means for modification of the structure of the composite by coarsening mechanisms, and thereby changes its properties. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4720464]
Resumo:
The Carr-Purcell pulse sequence, with low refocusing flip angle, produces echoes midway between refocusing pulses that decay to a minimum value dependent on T*(2). When the refocusing flip angle was pi/2 (CP90) and tau > T*(2), the signal after the minimum value, increased to reach a steady-state free precession regime (SSFP), composed of a free induction decay signal after each pulse and an echo, before the next pulse. When tau < T*(2), the signal increased from the minimum value to the steady-state regime with a time constant (T*) = 2T(1)T(2)/(T-1 + T-2). identical to the time constant observed in the SSFP sequence, known as the continuous wave free precession (CWFP). The steady-state amplitude obtained with M-cp90 = M0T2/(T-1+T-2) was identical to CWFP. Therefore, this sequence was named CP-CWFP because it is a Carr-Purcell sequence that produces results similar to the CWFP. However, CP-CWFP is a better sequence for measuring the longitudinal and transverse relaxation times in single scan, when the sample exhibits T-1 similar to T-2. Therefore, this sequence can be a useful method in time domain NMR and can be widely used in the agriculture, food and petrochemical industries because those samples tend to have similar relaxation times in low magnetic fields. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.
Resumo:
Objective: To assess the effects produced by the MARA appliance in the treatment of Angle’s Class II, division 1 malocclusion. Methods: The sample consisted of 44 young patients divided into two groups: The MARA Group, with initial mean age of 11.99 years, treated with the MARA appliance for an average period of 1.11 years, and the Control Group, with initial mean age of 11.63 years, monitored for a mean period of 1.18 years with no treatment. Lateral cephalograms were used to compare the groups using cephalometric variables in the initial and final phases. For these comparisons, Student’s t test was employed. Results: MARA appliance produced the following effects: Maxillary growth restriction, no change in mandibular development, improvement in maxillomandibular relationship, increased lower anterior facial height and counterclockwise rotation of the functional occlusal plane. In the upper arch, the incisors moved lingually and retruded, while the molars moved distally and tipped distally. In the lower arch, the incisors proclined and protruded, whereas the molars mesialized and tipped mesially. Finally, there was a significant reduction in overbite and overjet, with an obvious improvement in molar relationship. Conclusions: It was concluded that the MARA appliance proved effective in correcting Angle’s Class II, division 1 malocclusion while inducing skeletal changes and particularly dental changes.
Resumo:
Objective: This study evaluated the variations in the anterior cranial base (S-N), posterior cranial base (S-Ba) and deflection of the cranial base (SNBa) among three different facial patterns (Pattern I, II and III). Method: A sample of 60 lateral cephalometric radiographs of Brazilian Caucasian patients, both genders, between 8 and 17 years of age was selected. The sample was divided into 3 groups (Pattern I, II and III) of 20 individuals each. The inclusion criteria for each group were the ANB angle, Wits appraisal and the facial profile angle (G’.Sn.Pg’). To compare the mean values obtained from (SNBa, S-N, S-Ba) each group measures, the ANOVA test and Scheffé’s Post-Hoc test were applied. Results and Conclusions: There was no statistically significant difference for the deflection angle of the cranial base among the different facial patterns (Patterns I, II and III). There was no significant difference for the measures of the anterior and posterior cranial base between the facial Patterns I and II. The mean values for S-Ba were lower in facial Pattern III with statistically significant difference. The mean values of S-N in the facial Pattern III were also reduced, but without showing statistically significant difference. This trend of lower values in the cranial base measurements would explain the maxillary deficiency and/or mandibular prognathism features that characterize the facial Pattern III.
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
Resumo:
OBJECTIVE: Define and compare numbers and types of occlusal contacts in maximum intercuspation. METHODS: The study consisted of clinical and photographic analysis of occlusal contacts in maximum intercuspation. Twenty-six Caucasian Brazilian subjects were selected before orthodontic treatment, 20 males and 6 females, with ages ranging between 12 and 18 years. The subjects were diagnosed and grouped as follows: 13 with Angle Class I malocclusion and 13 with Angle Class II Division 1 malocclusion. After analysis, the occlusal contacts were classified according to the established criteria as: tripodism, bipodism, monopodism (respectively, three, two or one contact point with the slope of the fossa); cuspid to a marginal ridge; cuspid to two marginal ridges; cuspid tip to opposite inclined plane; surface to surface; and edge to edge. RESULTS: The mean number of occlusal contacts per subject in Class I malocclusion was 43.38 and for Class II Division 1 malocclusion it was 44.38, this difference was not statistically significant (p>0.05). CONCLUSIONS: There is a variety of factors that influence the number of occlusal contacts between a Class I and a Class II, Division 1 malocclusion. There is no standardization of occlusal contact type according to the studied malocclusions. A proper selection of occlusal contact types such as cuspid to fossa or cuspid to marginal ridge and its location in the teeth should be individually defined according to the demands of each case. The existence of an adequate occlusal contact leads to a correct distribution of forces, promoting periodontal health.
Resumo:
Questo progetto di ricerca, è stato sviluppato per studiare le caratteristiche anatomofunzionali che definiscono l’articolazione del gomito, ed in modo articolare la presenza dell’angolazione valga che origina dalla diversa orientazione degli assi meccanici dell’avambraccio e del braccio e, denominata in letteratura come carrying angle. L’obiettivo principale di questo lavoro - meglio espresso nei diversi capitoli - è stato, quello di identificare un nuovo approccio di misura per la stima di questo angolo, utilizzabile sia per gli studi di biomeccanica articolare, che per gli studi di analisi del movimento per l’arto superiore. Il primo obiettivo è stato quello di scegliere un algoritmo di calcolo che rispettasse le caratteristiche dell’articolazione, ed in modo particolare abile a minimizzare gli errori introdotti sia nella fase di acquisizione dei punti di repere anatomici, che in quella legata alla predizione del movimento di flesso-estensione, con un modello matematico. Per questo motivo abbiamo dovuto realizzare una serie di misure in un primo tempo su due cadaveri di arto superiore, poi, seguendo le regole classiche per la validazione dell’approccio metodologico adottato, si sono realizzate misure in-vivo, prima in massima estensione e poi durante il movimento. Inizialmente abbiamo pensato di comparare le misure lineari relative alle ampiezze del braccio (ampiezza tra l’epicondilo laterale e mediale) e dell’avambraccio (ampiezza tra lo stiloide ulnare e radiale) con quelle ottenute mediante un antropometro; successivamente dopo aver verificato la ripetibilità tra i diversi operatori nell’ acquisizione dei punti di repere anatomici con il digitalizzatore Faro Arm, abbiamo comparato le misure ottenute relative al carrying angle con quelle di un goniometro standard, classicamente utilizzato nella pratica clinica per la definizione dei range di movimento dell’arto superiore. Infine, considerando la bontà delle misure ottenute, abbiamo riproposto tale metodologia con stumenti stereofotogrammetrici per l’analisi del movimento (VICON System), ottenendo la stessa stabilit`a nell’andamento del carrying angle in funzione della flessione, sia come riportato dagli studi in letteratura, sia come riscontrato nel nostro studio in-vitro. In conclusione, questo lavoro di ricerca ha evidenziato (sia per i risultati ottenuti, che per la elevata numerosità dei soggetti testati), come gli esseri umani presentino una grande variabilità individuale nel valore di questo angolo, e di come questo possa aiutare per la corretta definizione di un modello 3-D dell’arto superiore. Pertanto, gli studi futuri sulla biomeccanica dell’arto superiore dovrebbero includere sempre la valutazione di questa misura.