927 resultados para HARMONIC IMPEDANCE
Resumo:
An optical autocorrelator grown on a (211)B GaAs substrate that uses visible surface-emitted second-harmonic generation is demonstrated. The (211)B orientation needs TE mode excitation only, thus eliminating the problem of the beating between the TE and TM modes that is required for (100)-grown devices; it also has the advantage of giving higher upconversion efficiency than (111) growth. Values of waveguide loss and the difference in the effective refractive index between the TE(0) and TE(1) modes were also obtained from the autocorrelation experiment.
Resumo:
The technology of low-loss orientation-patterned gallium arsenide (OP-GaAs) waveguided crystals was developed and realized by reduction of diffraction scattering on the waveguide pattern. The propagation losses in the OP-GaAs waveguide were estimated to be as low as 2.1 dB/cm, thus demonstrating the efficient second harmonic generation at 1621 nm under an external pumping. © 2013 Optical Society of America.
Resumo:
The rhythm created by spacing a series of brief tones in a regular pattern can be disguised by interleaving identical distractors at irregular intervals. The disguised rhythm can be unmasked if the distractors are allocated to a separate stream from the rhythm by integration with temporally overlapping captors. Listeners identified which of 2 rhythms was presented, and the accuracy and rated clarity of their judgment was used to estimate the fusion of the distractors and captors. The extent of fusion depended primarily on onset asynchrony and degree of temporal overlap. Harmonic relations had some influence, but only an extreme difference in spatial location was effective (dichotic presentation). Both preattentive and attentionally driven processes governed performance. (PsycINFO Database Record (c) 2012 APA, all rights reserved)
Resumo:
In this paper, we investigated the effect of hydrogen termination on the electrical properties and impedance spectra of detonation nanodiamond. The impedance spectra revealed that the hydrogen-termination process increases the electrical conductivity by four orders of magnitude at room temperature. An equivalent circuit has been proposed to correlate with the conduction mechanism. Arrhenius plot showed that there were two different activation energy levels located at 0.089 eV and 0.63 eV between 50 °C and 400 °C. The possible physical mechanism corresponding to these activation energy levels has been discussed. Hydrogen-terminated detonation nanodiamond has been further annealed at different temperatures prior to FTIR and XPS measurements in order to understand their thermal stability. The results demonstrated that the surface oxidization occurred between 100 °C and 150 °C. However, the C-H bonds could partially survive when the temperature reaches 400 °C in air. © 2013 American Institute of Physics.
Resumo:
We present a novel optical comb generation technique based on the use of a multi-harmonic electrical signal for driving the MZM. The proposed scheme is highly power efficient and gives rise to square shaped combs of advanced flatness and side mode suppression ratio while maintaining a stable performance over a long time period. © 2012 OSA.
Resumo:
Bio-impedance analysis (BIA) provides a rapid, non-invasive technique for body composition estimation. BIA offers a convenient alternative to standard techniques such as MRI, CT scan or DEXA scan for selected types of body composition analysis. The accuracy of BIA is limited because it is an indirect method of composition analysis. It relies on linear relationships between measured impedance and morphological parameters such as height and weight to derive estimates. To overcome these underlying limitations of BIA, a multi-frequency segmental bio-impedance device was constructed through a series of iterative enhancements and improvements of existing BIA instrumentation. Key features of the design included an easy to construct current-source and compact PCB design. The final device was trialled with 22 human volunteers and measured impedance was compared against body composition estimates obtained by DEXA scan. This enabled the development of newer techniques to make BIA predictions. To add a ‘visual aspect’ to BIA, volunteers were scanned in 3D using an inexpensive scattered light gadget (Xbox Kinect controller) and 3D volumes of their limbs were compared with BIA measurements to further improve BIA predictions. A three-stage digital filtering scheme was also implemented to enable extraction of heart-rate data from recorded bio-electrical signals. Additionally modifications have been introduced to measure change in bio-impedance with motion, this could be adapted to further improve accuracy and veracity for limb composition analysis. The findings in this thesis aim to give new direction to the prediction of body composition using BIA. The design development and refinement applied to BIA in this research programme suggest new opportunities to enhance the accuracy and clinical utility of BIA for the prediction of body composition analysis. In particular, the use of bio-impedance to predict limb volumes which would provide an additional metric for body composition measurement and help distinguish between fat and muscle content.
Resumo:
We present a compact, all-room-temperature continuous-wave laser source in the visible spectral region between 574 and 647 nm by frequency doubling of a broadly tunable InAs/GaAs quantum-dot external-cavity diode laser in a periodically poled potassium titanyl phosphate crystal containing three waveguides with different cross-sectional areas (4 × 4, 3 × 5, and 2 μm × 6 μm). The influence of a waveguide's design on tunability, output power, and mode distribution of second-harmonic generated light, as well as possibilities to increase the conversion efficiency via an optimization of a waveguide's cross-sectional area, was systematically investigated. A maximum output power of 12.04 mW with a conversion efficiency of 10.29% at 605.6 nm was demonstrated in the wider waveguide with the cross-sectional area of 4 μm × 4 μm.
Resumo:
Impedance spectroscopy (IS) analysis is carried out to investigate the electrical properties of the metal-oxide-semiconductor (MOS) structure fabricated on hydrogen-terminated single crystal diamond. The low-temperature atomic layer deposition Al2O3 is employed as the insulator in the MOS structure. By numerically analysing the impedance of the MOS structure at various biases, the equivalent circuit of the diamond MOS structure is derived, which is composed of two parallel capacitive and resistance pairs, in series connection with both resistance and inductance. The two capacitive components are resulted from the insulator, the hydrogenated-diamond surface, and their interface. The physical parameters such as the insulator capacitance are obtained, circumventing the series resistance and inductance effect. By comparing the IS and capacitance-voltage measurements, the frequency dispersion of the capacitance-voltage characteristic is discussed.
Resumo:
Mathematics Subject Classification: 35J05, 35J25, 35C15, 47H50, 47G30
Resumo:
MSC 2010: 30C45, 30C55
Resumo:
MSC 2010: 30C45, 30C55
Resumo:
MSC 2010: 30C45, 30C55
Resumo:
MSC 2010: 30C55, 30C45
Resumo:
We report experimental study of vector solitons for the fundamental and harmonic mode-locked operation in erbiumdoper fiber lasers with carbon nanotubes based saturable absorbers and anomalous dispersion cavities. We measure evolution of the output pulses polarization and demonstrate vector solitons with various polarization attractors, including locked polarization, periodic polarization switching, and polarization precession.
Resumo:
We study polarization dynamics of a harmonic mode-locked erbium-doped fiber laser with carbon nanotubes absorber. New types of vector solitons are shown for multi-pulse and harmonic mode-locked operation with locked, switching and precessing polarization states. © 2014 OSA.