921 resultados para Gap


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of remote labs in undergraduate courses has been reported in literature several times since the mid 90's. Nevertheless, very few articles present results about the correspondent learning gains obtained by students, and in what conditions those systems can be more efficient, thus suggesting a lack of data concerning their pedagogical effectiveness. This paper addresses such a gap by presenting some initial findings concerning the use of a remote lab (VISIR), in a large undergraduate course on Physics, with over 550 students enrolled.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of remote labs in undergraduate courses has been reported in literature several times since the mid 90's. Nevertheless, very few articles present results about the learning gains obtained by students using them, especially with a large number of students, thus suggesting a lack of data concerning their pedagogical effectiveness. This paper addresses such a gap by presenting some preliminary results concerning the use of a remote laboratory, known as VISIR, in a large undergraduate course on Applied Physics, with over 500 students enrolled.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado em Engenharia Informática

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we present results about the functioning of a multilayered a-SiC:H heterostructure as a device for wavelength-division demultiplexing of optical signals. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photogenerated carriers. Band gap engineering was used to adjust the photogeneration and recombination rates profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption and carrier collection in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. This photocurrent is used as an input for a demux algorithm based on the voltage controlled sensitivity of the device. The device functioning is explained with results obtained by numerical simulation of the device, which permit an insight to the internal electric configuration of the double heterojunction.These results address the explanation of the device functioning in the frequency domain to a wavelength tunable photocapacitance due to the accumulation of space charge localized at the internal junction. The existence of a direct relation between the experimentally observed capacitive effects of the double diode and the quality of the semiconductor materials used to form the internal junction is highlighted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) mu m have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanate nanotubes (TNT) with different sodium contents have been synthesised using a hydrothermal approach and a swift and highly controllable post-washing processes. The influence of the sodium/proton replacement on the structural and morphological characteristics of the prepared materials was analysed. Different optical behaviour was observed depending on the Na+/H+ samples’ content. A band gap energy of 3.27±0.03 eV was estimated for the material with higher sodium content while a value of 2.81±0.02 eV was inferred for the most protonated material, which therefore exhibits an absorption edge in the near visible region. The point of zero charge of the materials was determined and the influence of the sodium content on the adsorption of both cationic and anionic organic dyes was studied. The photocatalytic performance of the TNT samples was evaluated in the rhodamine 6G degradation process. Best photodegradation results were obtained when using the most protonated material as catalyst, although this material has shown the lowest R6G adsorption capability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A vulgarização do uso de dispositivos móveis promoveu a proliferação de aplicações dos mais diversos âmbitos para estes dispositivos não sendo a área clínica uma excepção. Tanto a nível profissional, como a nível de ensino, as tecnologias móveis foram já há muito adoptadas nesta área para as mais diversas finalidades. O trabalho aqui apresentado pretende essencialmente provar a real importância desempenhada pelo mobile learning no contexto da aprendizagem clínica. Mais do que implementar um simples recurso educativo, pretendeu-se conceber um sistema integrado que respondesse a todas as necessidades do aluno quer durante o estudo nas suas diversas fases e locais, como também no próprio serviço hospitalar onde se encontre a desempenhar funções como interno da especialidade. Após uma exaustiva análise das aplicações móveis relevantes da área médica, verificou-se a inexistência de uma ferramenta integradora de vários módulos de aprendizagem com um custo comportável para a maioria dos alunos. Desta forma, idealizou-se uma aplicação capaz de superar esta lacuna que será detalhada ao longo desta tese. Para o desenvolvimento deste trabalho contou-se com a preciosa colaboração dos possíveis utilizadores finais desta ferramenta uma vez que a escolha dos módulos a integrar foi essencialmente baseada nas suas opiniões. Ainda no âmbito desta tese, encontra-se a avaliação do protótipo por parte dos alunos. Esta avaliação pretende validar a efectiva importância de uma ferramenta desta natureza para um aluno de medicina assim como o impacto que o protótipo teve na sua opinião acerca do conceito de mobile learning na aprendizagem clínica. Com vista a uma futura implementação de um recurso educativo deste âmbito, foram também recolhidos os pontos negativos e positivos mais relevantes para o aluno. Em suma, este trabalho valida a importância do papel que as aplicações de aprendizagem para dispositivos móveis podem desempenhar para um aluno de medicina tanto nos seus locais de estudo, como no serviço onde se possa encontrar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports on a new and swift hydrothermal chemical route to prepare titanate nanostructures (TNS) avoiding the use of crystalline TiO2 as starting material. The synthesis approach uses a commercial solution of TiCl3 as titanium source to prepare an amorphous precursor, circumventing the use of hazardous chemical compounds. The influence of the reaction temperature and dwell autoclave time on the structure and morphology of the synthesised materials was studied. Homogeneous titanate nanotubes with a high length/diameter aspect ratio were synthesised at 160 degrees C and 24 h. A band gap of 3.06 +/- 0.03 eV was determined for the TNS samples prepared in these experimental conditions. This value is red shifted by 0.14 eV compared to the band gap value usually reported for the TiO2 anatase. Moreover, such samples show better adsorption capacity and photocatalytic performance on the dye rhodamine 6G (R6G) photodegradation process than TiO2 nanoparticles. A 98% reduction of the R6G concentration was achieved after 45 min of irradiation of a 10 ppm dye aqueous solution and 1 g L-1 of TNS catalyst.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Relatório de estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1.º e 2.º Ciclo do Ensino Básico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação teve como objetivo o estudo de uma central de climatização adiabática, que tem como finalidade controlar a temperatura e a humidade de um salão com equipamentos de torcedura e de bobinagem, pertencente à Continental - ITA. Foi realizado um levantamento de dados relativamente à temperatura e humidade interior e exterior do referido salão. Verificou-se que estes parâmetros não estavam dentro dos valores ótimos desejados, 26 ± 1˚C e 50 ± 5%, e por isso foi necessário estimar as necessidades nominais de arrefecimento. Este valor foi determinado a partir do Regulamento das Características de Comportamento Térmico dos Edifícios (RCCTE), obtendo-se o valor de 79 kWh/m2.˚C. No sentido de avaliar se as centrais de climatização instaladas no salão em estudo satisfaziam estas necessidades, calcularam-se as suas capacidades de arrefecimento obtendo-se um valor máximo de 64 kWh/m2.˚C. Paralelamente a este estudo, foi calculada a eficiência de humidificação para cada central nos meses de março e setembro. Os valores obtidos foram oscilantes obtendo-se um valor máximo de 100% em setembro. Este fato deve-se à temperatura exterior neste mês ser mais alta e, por consequência, a eficiência de humidificação da central é maior, pois a quantidade de água que o ar pode conter na sua composição é também mais elevada. Com o objetivo de colmatar a diferença entre as necessidades nominais de arrefecimento e a capacidade de arrefecimento das centrais, foram analisadas algumas soluções que, a serem implementadas, poderiam ajudar na poupança energética. Uma dessas soluções era a substituição do sistema atual de humidificação por um sistema mais eficiente de alta pressão. Com o estudo económico deste investimento obteve-se um período de retorno de dois anos. Foram ainda apresentados mais dois investimentos onde foi alterado o sistema de controlo automático existente, obtendo-se para um, dois anos de período de retorno e para o outro três anos e meio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background - Medical image perception research relies on visual data to study the diagnostic relationship between observers and medical images. A consistent method to assess visual function for participants in medical imaging research has not been developed and represents a significant gap in existing research. Methods - Three visual assessment factors appropriate to observer studies were identified: visual acuity, contrast sensitivity, and stereopsis. A test was designed for each, and 30 radiography observers (mean age 31.6 years) participated in each test. Results - Mean binocular visual acuity for distance was 20/14 for all observers. The difference between observers who did and did not use corrective lenses was not statistically significant (P = .12). All subjects had a normal value for near visual acuity and stereoacuity. Contrast sensitivity was better than population norms. Conclusion - All observers had normal visual function and could participate in medical imaging visual analysis studies. Protocols of evaluation and populations norms are provided. Further studies are necessary to understand fully the relationship between visual performance on tests and diagnostic accuracy in practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intent of this dissertation is to review relevant existing management systems and chemical industry initiatives to identify synergies, overlaps and gaps with Sustainability best practices, to map the barriers to the incorporation of Sustainability and formulate recommendations to facilitate execution of Sustainability practices within existing management systems. A chemical industry Sustainability survey was conducted through APEQ, the Portuguese association of chemical companies, which constitutes the first baseline on the topic for this national industry association. The commonly used international standards and the Responsible Care® (RC) initiative were cross-referenced against the United Nations Global Compact Assessment Tool. Guidance on how to incorporate Sustainability into a company‘s modus operandi was collapsed into Sustainability Playbooks. The survey revealed that 73% of the APEQ member companies that participated in the survey have a Sustainability Plan. Both large and small/medium APEQ member companies see the market not willing to pay extra for ‗greener‘ products as one of the main barriers. APEQ large enterprise see complexity of implementation and low return on investment as the other most significant barriers while small/medium enterprise respond that the difficulty to predict customer sustainability needs is the other most significant barrier. Amongst many other insights from this survey reported to APEQ, Life Cycle Assessment practices were found to have a low level of implementation and were also considered of low importance, thus identifying a very important opportunity in Sustainability practices to be addressed by APEQ. Two hundred and seventy three assessment points from United Nations Global Compact Assessment Tool plus five additional items were cross-referenced with international standard requirements. With the authorization of the intellectual property owners, the United Nations Global Compact Assessment Tool was modified to introduce actionable recommendations for each gap identified by management standard. This tool was automated to output specific recommendations for 63 possible combinations after simply selecting from a list of commonly used management standards and the RC initiative. Finally this modified tool was introduced into Playbooks for Incorporation of Sustainability at two levels: a ―Get Started Playbook‖ for beginners or small/medium size enterprise and an ―Advanced Playbook‖ as a second advancement stage or for large enterprise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A satisfação profissional é um tema atual, sendo alvo de diversas investigações, devido a este ter sido reconhecido como parte integrante nos cuidados de saúde como indicador de qualidade. De acordo com Spector (1997), a satisfação profissional pode ser explicada como medida no qual o trabalhador gosta do seu trabalho (satisfação profissional) ou não gosta do ser trabalho (insatisfação profissional). No entanto devido a conjuntura socioeconómica em que o país se encontra, e as constantes alterações vigentes no setor da saúde, parece fundamental avaliar as consequências destas alterações na satisfação profissional dos profissionais da saúde. Delineou-se este estudo, não experimental, descritivo e transversal com o objetivo principal de comparar e avaliar os níveis de satisfação profissional dos Técnicos de Radiologia a exercer funções no setor privado e público. Analisou-se também a relação da satisfação profissional com algumas variáveis sociodemográficas, nomeadamente a idade, género, remuneração e a experiência profissional. Para a recolha dos dados utilizou-se o questionário Minnesota Satisfaction Questionnaire-short version (Martins, 2012), sendo divulgado através de um inquérito on-line. No estudo participaram 110 técnicos de radiologia a nível nacional (40 a exercer funções no setor privado e 42 a exercer funções no setor público). Os resultados do presente estudo evidenciaram uma ligeira satisfação profissional (na autonomia, realização profissional, ambiente e chefia) nos técnicos de radiologia. Os técnicos de radiologia a exercer funções no setor público apresentam uma maior satisfação com a sua autonomia, que os técnicos de radiologia a exercer funções no setor privado. Foram evidenciadas correlações entre a satisfação profissional com a remuneração, a experiência profissional, a idade e o género. A escassez de estudos sobre a satisfação profissional dos técnicos de radiologia no setor privado e público é uma lacuna, fazendo deste estudo um estudo importante e revolucionário para direcionar novos estudos.