984 resultados para Función ventricular
Resumo:
VT Ablation in Apical Hypertrophic Cardiomyopathy.
Resumo:
The aim of this study was to perform a systematic evaluation of safety and midterm complications after epicardial ventricular tachycardia (VT) ablation.
Resumo:
As the population ages, recurrent ventricular tachycardia (VT) is increasingly encountered in elderly patients with ischemic heart disease. Radiofrequency catheter ablation is useful for reducing VT therapy in patients with an implantable defibrillator. The utility of radiofrequency catheter ablation in the elderly is not well defined.
Resumo:
To assess cardiac morphologic and functional adaptations in elite triathletes with magnetic resonance (MR) imaging and to compare findings to those in recreationally active control subjects.
Resumo:
Recent data have suggested a relation among long-term endurance sport practice, left atrial remodeling, and atrial fibrillation. We investigated the influence of an increased vagal tone, represented by the early repolarization (ER) pattern, on diastolic function and left atrial size in professional soccer players. Fifty-four consecutive athletes underwent electrocardiography, echocardiography, and exercise testing as part of their preparticipation screening. Athletes were divided into 2 groups according to presence or absence of an ER pattern, defined as a ST-segment elevation at the J-point (STE) > or =0.1 mm in 2 leads. For linear comparisons average STE was calculated. Mean age was 24 +/- 4 years. Twenty-five athletes (46%) showed an ER pattern. Athletes with an ER pattern had a significant lower heart rate (54 +/- 9 vs 62 +/- 11 beats/min, p = 0.024), an increased E/e' ratio (6.1 +/- 1.2 vs 5.1 +/- 1.0, p = 0.002), and larger volumes of the left atrium (25.6 +/- 7.3 vs 21.8 +/- 5.0 ml/m(2), p = 0.031) compared to athletes without an ER pattern. There were no significant differences concerning maximum workload, left ventricular dimensions, and systolic function. Univariate regression analysis revealed significant correlations among age, STE, and left atrial volume. In a stepwise multivariate regression analysis age, STE and e' contributed independently to left atrial size (r = 0.659, p <0.001). In conclusion, athletes with an ER pattern had an increased E/e' ratio, reflecting a higher left atrial filling pressure, contributing to left atrial remodeling over time.
Resumo:
ABSTRACT: Horse kicks are rare incidents-especially, if they end in fatality. In this case, a 13-year-old girl collapsed 3 minutes after sustaining a kick to the chest from a pony. Resuscitation attempts were unsuccessful. Postmortem computed tomography and magnetic resonance imaging were performed before autopsy.Imaging revealed a 3-cm long laceration of the left ventricle and a large pericardial effusion. Using segmentation techniques, the amount of blood inside the pericardium was determined. These findings correlated well with the autopsy findings. Pericardial tamponade was determined at autopsy to be the cause of death.Postmortem imaging may prove useful for the diagnosis of these types of injury, but further studies are needed to document accuracy.
Resumo:
Patients with left ventricular noncompaction (LVNC) have an increased risk for life-threatening ventricular arrhythmias. The benefit from implantable cardioverter-defibrillators (ICD) in these patients has been investigated only in small series. Therefore, the aim of the present study was to analyze the clinical outcome of a larger population of patients with LVNC who were treated with an ICD.
Resumo:
The accurate position of the ventricular catheter inside the frontal horn of the lateral ventricle is essential to prevent proximal failure in shunt surgery. For optimal placement, endoscopic- and image-guided techniques are available.
Resumo:
Catheter-related infection of CSF is a potentially life-threatening complication of external ventricular drainage (EVD). When using EVD catheters, contact between the ventricular system and skin surface occurs and CSF infection is possible. The aim of this analysis was to compare the efficacy of silver-bearing EVD catheters for reducing the incidence of infection with standard nonimpregnated EVD catheters in neurosurgical patients with acute hydrocephalus.
Resumo:
Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.
Resumo:
Introduction Reduced left ventricular function in patients with severe symptomatic valvular aortic stenosis is associated with impaired clinical outcome in patients undergoing surgical aortic valve replacement (SAVR). Transcatheter Aortic Valve Implantation (TAVI) has been shown non-inferior to SAVR in high-risk patients with respect to mortality and may result in faster left ventricular recovery. Methods We investigated clinical outcomes of high-risk patients with severe aortic stenosis undergoing medical treatment (n = 71) or TAVI (n = 256) stratified by left ventricular ejection fraction (LVEF) in a prospective single center registry. Results Twenty-five patients (35%) among the medical cohort were found to have an LVEF≤30% (mean 26.7±4.1%) and 37 patients (14%) among the TAVI patients (mean 25.2±4.4%). Estimated peri-interventional risk as assessed by logistic EuroSCORE was significantly higher in patients with severely impaired LVEF as compared to patients with LVEF>30% (medical/TAVI 38.5±13.8%/40.6±16.4% versus medical/TAVI 22.5±10.8%/22.1±12.8%, p <0.001). In patients undergoing TAVI, there was no significant difference in the combined endpoint of death, myocardial infarction, major stroke, life-threatening bleeding, major access-site complications, valvular re-intervention, or renal failure at 30 days between the two groups (21.0% versus 27.0%, p = 0.40). After TAVI, patients with LVEF≤30% experienced a rapid improvement in LVEF (from 25±4% to 34±10% at discharge, p = 0.002) associated with improved NYHA functional class at 30 days (decrease ≥1 NYHA class in 95%). During long-term follow-up no difference in survival was observed in patients undergoing TAVI irrespective of baseline LVEF (p = 0.29), whereas there was a significantly higher mortality in medically treated patients with severely reduced LVEF (log rank p = 0.001). Conclusion TAVI in patients with severely reduced left ventricular function may be performed safely and is associated with rapid recovery of systolic left ventricular function and heart failure symptoms.
Resumo:
Surgical treatment of mitral leaflet prolapse using artificial neochordae shows excellent outcomes. Upcoming devices attempt the same treatment in a minimally invasive way but target the left ventricular apex as an anchoring point, rather than the tip of the corresponding papillary muscle. In this study, cine cardiac magnetic resonance imaging was used to compare these 2 different anchoring positions and their dynamic relationship with the mitral leaflets.
Resumo:
The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.