921 resultados para Flavor–nutrient conditioning
Resumo:
The conventional Newton's method has been considered inadequate to obtain the maximum loading point (MLP) of power systems. It is due to the Jacobian matrix singularity at this point. However, the MLP can be efficiently computed through parameterization techniques of continuation methods. This paper presents and tests new parameterization schemes, namely the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, the reactive power at shunts (capacitor or reactor), the transmission lines power losses (real and reactive), and transmission lines power (real and reactive). Besides their clear physical meaning, which makes easier the development and application of continuation methods for power systems analysis, the main advantage of some of the proposed parameters is that its not necessary to change the parameter in the vicinity of the MLP. Studies on the new parameterization schemes performed on the IEEE 118 buses system show that the ill-conditioning problems at and near the MLP are eliminated. So, the characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2003 Elsevier B.V. B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os métodos de fluxo de carga por Newton-Raphson e fluxo de carga desacoplado rápido convencionais são considerados inadequados para a obtenção do ponto de máximo carregamento de sistemas de potência, devido à problemas de mal-condicionamento neste ponto crítico e na sua vizinhança. Neste ponto a matriz Jacobiana do método de Newton-Raphson torna-se singular e considera-se que não são mais válidas as hipóteses de desacoplamento P-V e Q-teta utilizadas para a formulação do método fluxo de carga desacoplado rápido. No entanto, mostra-se neste trabalho, que com pequenas modificações, as versões XB e BX do fluxo de carga desacoplado rápido tornam-se adequadas para a obtenção do ponto de máximo carregamento. Estas novas versões modificadas são comparadas entre si com o intuito de explicitar suas características, assim como da influência da atuação dos limites de geração de potência reativa e de tap's de transformadores. Os resultados obtidos para os sistemas testes do IEEE (14, 30, 57 e 118 barras) mostram que as características de convergência das versões originais são preservadas. Além disso, durante o traçado das curvas PV, os diversos métodos podem ser comutados entre si possibilitando o cálculo de todos os pontos da curva com um número reduzido de iterações.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Continuation methods have been long used in P-V curve tracing due to their efficiency in the resolution of ill-conditioned cases, with close to singular Jacobian matrices, such as the maximum loading point of power systems. Several parameterization techniques have been proposed to avoid matrix singularity and successfully solve those cases. This paper presents a simple geometric parameterization technique to overcome the singularity of the Jacobian matrix by the addition of a line equations located at the plane determined by a bus voltage magnitude and the loading factor. This technique enlarges the set of voltage variables that can be used to whole P-V curve tracing, without ill-conditioning problems and no need of parameter changes. Simulation results, obtained for large realistic Brazilian and American power systems, show that the robustness and efficiency of the conventional power flow are not only preserved but also improved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.
Resumo:
CONTEXTUALIZAÇÃO: Diagnosticar os parâmetros clínicos associados com as quedas em idosos tornou-se um grande desafio para a comunidade científica. Apesar da existência de diversos instrumentos direcionados à avaliação do equilíbrio corporal em idosos, ainda é escasso o número de trabalhos que investigaram e discutiram a concordância entre os diversos métodos. OBJETIVO: Analisar a correlação entre alguns testes usados para avaliar o equilíbrio corporal no idoso. MÉTODOS: Tratou-se de um estudo transversal, observacional, realizado com 30 voluntárias idosas comunitárias, hígidas, com diferentes níveis de condicionamento físico. Foram utilizados o Teste de Alcance Funcional Anterior (TAF), a Escala de Equilíbrio de Berg (EEB), o teste Timed Up and Go (TUG) e o Teste de Equilíbrio de Tinetti (Performance Oriented Mobility Assessment - POMA). A correlação dos dados foi realizada por meio da aplicação do Coeficiente de Correlação de Spearman, com nível de significância de 5% (p<0,05). RESULTADOS: Observou-se correlação positiva e moderada entre o TAF e a EEB (r=0,4845; p=0,0067), entre o TAF e a POMA (r=0,4136; p= 0,0231), entre a EEB e a POMA (r=0,6088; p=0,0004). CONCLUSÃO: Os testes são complementares, dado que se mostraram com particularidades e limitações distintas. Torna-se razoável, portanto, a aplicação conjunta desses instrumentos para melhor avaliar o equilíbrio de idosas.
Resumo:
OBJETIVO: Investigar os fatores associados à diferença clinicamente significativa da qualidade de vida (DCSQV) após condicionamento físico em pacientes com DPOC. MÉTODOS: Trinta e cinco pacientes foram submetidos a 12 semanas de condicionamento físico, envolvendo treinamento de força e exercício aeróbio leve. Composição corporal, teste incremental e de endurance em esteira, teste de caminhada de seis minutos, força muscular periférica, PImáx, baseline dyspnea index (BDI) e Saint George's Respiratory Questionnaire (SGRQ) foram avaliados antes e após o treinamento, e suas alterações (Δ) foram calculadas. A DCSQV foi definida como a redução > 4% no escore total do SGRQ. Os pacientes que responderam ao treinamento, apresentando DCSQV, foram alocados no grupo respondedores (R; n = 24), e os demais pacientes foram alocados no grupo não-respondedores (NR; n = 11). RESULTADOS: Os seguintes resultados foram significativamente maiores no grupo R que no grupo NR (p < 0,05): VEF1 (1,48 ± 0,54 L vs. 1,04 ± 0,34 L), VEF1/CVF (47,9 ± 11,7% vs. 35,5 ± 10,7%), PaO2 (74,1 ± 9,7 mmHg vs. 65,0 ± 8,9mmHg) e ΔBDI [mediana (interquartil); 2,0 (0,0-3,5) vs. 0,0 (0,0-1,0)]. Houve correlação significativa (p < 0,01) de ΔSGRQ-sintomas (r = 0,44), ΔSGRQ-atividade (r = 0,62) e ΔSGRQ-total (r = 0,60) com ΔBDI. Após regressão logística, apenas ΔBDI foi selecionado como determinante da DCSQV. CONCLUSÕES: A DCSQV após o condicionamento físico está associada principalmente à redução da dispneia nos pacientes com DPOC. Portanto, são necessárias estratégias de tratamento visando interromper o ciclo dispneia-sedentarismo-dispneia nesses pacientes.
Resumo:
In the current work are presented the results about the study of digital mapping of analogs referents the fluvial oil reservoirs in the Açu Formation. With the regional recognizing in the south corner of Potiguar Basin was selected a area of 150 Km square in the west of Assu city. In this area was chosen the outcrops for the digital mapping and from the data fields and remote sensors were done the depositional architectural for the fluvial deposits, which it was named coarse meandering fluvial systems. In the deposits were individualized 3 (three) fluvial cycles, which they was separated by bounding surface of fifth order. Such cycles are preferentially sandy, with fining-upward sequence finished in flood plain deposits. Inner of the sandy levels of the filling channels were characterized least cycles, normaly incomplete, constituted by braided sandy bodies and bounding surfaces of fourth order. In the mapped area was chosen a outcrop with great exposition, where it was possible to see tipical deposits of filling channel and was in this outcrop that was done the digital mapping. In this outcrop was used diverse technics and tools, which they integrated sedimentological, altimetric (GPS, Total Station), LIDAR (Light Detection and Ranging), digital photomosaic of high resolution and of the inner geometries (Ground Penetration Radar) data sets. For the integrating, interpretation and visualization of data was used software GoCAD®. The final product of the outcrop digital mapping was the photorealistic model of part of the cliff (or slope) because the observed reflectors in the radargrams were absents. A part of bar oblique accretion was modeled according to GPR gride of 200x200 meters in the alluvial Assu river probable recent analog. With the data of inner geometries was developed the three-dimentional sedimentary architectural, where it was possible characterize sand sheet deposits and many hierarchy of braided channels. At last, simulations of sedimentary geometries and architectures of the Potiguar Basin Fluvial Reservoirs were done with PetBool software, in order to understand the capacity of this program in simulations with a lot of numbers of conditioning wells. In total, 45 simulations was acquired, where the time and the channel numbers increase in relation of the conditioning wells quantity. The deformation of the meanders was detected from the change of simulated dominion dimensions. The presence of this problem was because the relationship between the simulated dominion and the width of the meander
Resumo:
This work aims to check whether there is a congruence between the purposes of regulations imposed by SIAB and the materiality constitution of places where your information is produced, since our hypothesis is that there is a mismatch between the rules and forms, which means, between reality as it is in places and how the territory is scrutinized by the Family Health Strategy (FHS) as for the performance of their teams as to the generation of their information. For this, the methodology used was the literature, documentary and empirical research, in special about territorialization of the Family Health strategy of Natal-RN. From the empirical mediation was possible to see the gap between full exploration and information produced by the ESF and the reality of the places. Thus, we highlight the importance of considering the conditioning of geographical forms as a guiding principle of the strategy for Family Health
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pacientes com doença pulmonar obstrutiva crônica apresentam comumente fraqueza muscular periférica associada à intolerância ao exercício. Embora efetivo, o exercício aeróbio apresenta pouco ou nenhum efeito na fraqueza e atrofia muscular, além de não ser tolerado pela maioria dos pacientes com DPOC. Nesse sentido, o treinamento de força é opção racional para aumentar a força muscular, além de já ter se mostrado mais tolerável que o exercício aeróbio. O aumento de força muscular periférica é o benefício mais consistente do treinamento de força e, quando este é associado ao exercício aeróbio, não resulta em melhora adicional da capacidade de exercício, da dispnéia e da qualidade de vida. Contudo, observa-se que o treinamento combinado é fisiologicamente mais completo e pode ser uma opção de condicionamento físico mais diversificado. O treinamento de moderada a alta intensidade resulta em maiores adaptações fisiológicas, entretanto o exercício de baixa intensidade é tolerável, simples, de fácil execução domiciliar, não requer equipamentos sofisticados e resulta em benefícios significativos. Este exercício é indicado, sobretudo, para os pacientes com DPOC mais avançada. Finalmente, há evidências recentes de que o treinamento de força para os músculos do tronco é alternativa válida para melhorar a capacidade funcional de exercício e a função pulmonar em pacientes com DPOC. A presente revisão de literatura sugere a incorporação do treinamento de força como estratégia de rotina nos programas de reabilitação pulmonar. Pesquisas futuras são necessárias para avaliar os efeitos do treinamento de força na saúde mental, no desempenho em atividades de vida diária, na saúde osteoarticular, no risco de quedas e na função pulmonar, entre outros.
Resumo:
To evaluate the participation of the larynx and cervical trachea in conditioning inspired gases, we randomly allocated 16 mixed-breed dogs to two groups: group TT (tracheal tube; n = 8) and group LMA (laryngeal mask airway; n = 8). The dogs were anesthetized with pentobarbital sodium and mechanically ventilated for 3 hours. The parameters studied were temperature and absolute humidities of ambient, inhaled, and tracheal air. There was a small increase in tracheal air temperature compared to inhaled air temperature, but no significant difference between groups. The absolute humidity of tracheal air was greater in group LMA than in group TT (23 mg H2O center dot L-1 and 14 mg H2O center dot L-1, respectively; p < .0001). The difference in absolute humidity between the tracheal air and the inhaled air was higher in group LMA at all times (p < .0001). We conclude that the larynx and cervical trachea of the dog participate in humidification and heating of inhaled air by means of air contact with mucosa in this airway segment.