953 resultados para Flame tomography
Resumo:
Objectives: To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. Design: A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. Setting: All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. Participants: Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. Interventions: Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. Main outcome measures: (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). Results: Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Conclusions: Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. © Queen's Printer and Controller of HMSO 2013.
Resumo:
2000 Mathematics Subject Classification: 53C24, 53C65, 53C21.
Resumo:
PurposeTo develop and validate a classification system for focal vitreomacular traction (VMT) with and without macular hole based on spectral domain optical coherence tomography (SD-OCT), intended to aid in decision-making and prognostication.MethodsA panel of retinal specialists convened to develop this system. A literature review followed by discussion on a wide range of cases formed the basis for the proposed classification. Key features on OCT were identified and analysed for their utility in clinical practice. A final classification was devised based on two sequential, independent validation exercises to improve interobserver variability.ResultsThis classification tool pertains to idiopathic focal VMT assessed by a horizontal line scan using SD-OCT. The system uses width (W), interface features (I), foveal shape (S), retinal pigment epithelial changes (P), elevation of vitreous attachment (E), and inner and outer retinal changes (R) to give the acronym WISPERR. Each category is scored hierarchically. Results from the second independent validation exercise indicated a high level of agreement between graders: intraclass correlation ranged from 0.84 to 0.99 for continuous variables and Fleiss' kappa values ranged from 0.76 to 0.95 for categorical variables.ConclusionsWe present an OCT-based classification system for focal VMT that allows anatomical detail to be scrutinised and scored qualitatively and quantitatively using a simple, pragmatic algorithm, which may be of value in clinical practice as well as in future research studies.
Resumo:
Optical imaging is an emerging technology towards non-invasive breast cancer diagnostics. In recent years, portable and patient comfortable hand-held optical imagers are developed towards two-dimensional (2D) tumor detections. However, these imagers are not capable of three-dimensional (3D) tomography because they cannot register the positional information of the hand-held probe onto the imaged tissue. A hand-held optical imager has been developed in our Optical Imaging Laboratory with 3D tomography capabilities, as demonstrated from tissue phantom studies. The overall goal of my dissertation is towards the translation of our imager to the clinical setting for 3D tomographic imaging in human breast tissues. A systematic experimental approach was designed and executed as follows: (i) fast 2D imaging, (ii) coregistered imaging, and (iii) 3D tomographic imaging studies. (i) Fast 2D imaging was initially demonstrated in tissue phantoms (1% Liposyn solution) and in vitro (minced chicken breast and 1% Liposyn). A 0.45 cm3 fluorescent target at 1:0 contrast ratio was detectable up to 2.5 cm deep. Fast 2D imaging experiments performed in vivo with healthy female subjects also detected a 0.45 cm3 fluorescent target superficially placed ∼2.5 cm under the breast tissue. (ii) Coregistered imaging was automated and validated in phantoms with ∼0.19 cm error in the probe’s positional information. Coregistration also improved the target depth detection to 3.5 cm, from multi-location imaging approach. Coregistered imaging was further validated in-vivo , although the error in probe’s positional information increased to ∼0.9 cm (subject to soft tissue deformation and movement). (iii) Three-dimensional tomography studies were successfully demonstrated in vitro using 0.45 cm3 fluorescence targets. The feasibility of 3D tomography was demonstrated for the first time in breast tissues using the hand-held optical imager, wherein a 0.45 cm3 fluorescent target (superficially placed) was recovered along with artifacts. Diffuse optical imaging studies were performed in two breast cancer patients with invasive ductal carcinoma. The images showed greater absorption at the tumor cites (as observed from x-ray mammography, ultrasound, and/or MRI). In summary, my dissertation demonstrated the potential of a hand-held optical imager towards 2D breast tumor detection and 3D breast tomography, holding a promise for extensive clinical translational efforts.
Resumo:
Tumor functional volume (FV) and its mean activity concentration (mAC) are the quantities derived from positron emission tomography (PET). These quantities are used for estimating radiation dose for a therapy, evaluating the progression of a disease and also use it as a prognostic indicator for predicting outcome. PET images have low resolution, high noise and affected by partial volume effect (PVE). Manually segmenting each tumor is very cumbersome and very hard to reproduce. To solve the above problem I developed an algorithm, called iterative deconvolution thresholding segmentation (IDTS) algorithm; the algorithm segment the tumor, measures the FV, correct for the PVE and calculates mAC. The algorithm corrects for the PVE without the need to estimate camera's point spread function (PSF); also does not require optimizing for a specific camera. My algorithm was tested in physical phantom studies, where hollow spheres (0.5-16 ml) were used to represent tumors with a homogeneous activity distribution. It was also tested on irregular shaped tumors with a heterogeneous activity profile which were acquired using physical and simulated phantom. The physical phantom studies were performed with different signal to background ratios (SBR) and with different acquisition times (1-5 min). The algorithm was applied on ten clinical data where the results were compared with manual segmentation and fixed percentage thresholding method called T50 and T60 in which 50% and 60% of the maximum intensity respectively is used as threshold. The average error in FV and mAC calculation was 30% and -35% for 0.5 ml tumor. The average error FV and mAC calculation were ~5% for 16 ml tumor. The overall FV error was ∼10% for heterogeneous tumors in physical and simulated phantom data. The FV and mAC error for clinical image compared to manual segmentation was around -17% and 15% respectively. In summary my algorithm has potential to be applied on data acquired from different cameras as its not dependent on knowing the camera's PSF. The algorithm can also improve dose estimation and treatment planning.^
Resumo:
Brominated flame retardants (BFRs) have been found in Arctic wildlife, lake sediment, and air. To identify the atmospheric BFR deposition history on Svalbard, Norway, we analyzed 19 BFRs, including hexabromocyclododecane (HBCD), 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenyl ethane (DBDPE), pentabromoethylbenzene (PBEB),and 15 polybrominated diphenyl ether congeners (PBDE) in the upper 34 m of an ice core (representing 1953-2005) from Holtedahlfonna, the western-most ice sheet on Svalbard. All of the non-PBDE compounds were detected in nearly continuous profiles in the core. Seven PBDEs were not observed above background (28,47,66,100,99,154,153), while 4 were found in 1 or 2 of 6 segments (17,85,138,183). BDEs-49,71,190,209 had nearly continuous profiles but only BDE-209 in large amounts. The greatest inputs were HBCD and BDE-209, 910, and 320 pg/cm**2/yr from 1995-2005. DBDPE, BTBPE, and PBEB show nearly continuous input growth in recent core segments, but all were <6 pg/cm**2/yr. Long-range atmospheric processes may have moved these particle-bound BFRs to the site, probably during the Arctic haze season. Average air mass trajectories over 10 years show >75% of atmospheric flow to Holtedahlfonna coming from Eurasia during haze periods (March and April).
Resumo:
Radiolarians in the Arctic Ocean have been studied lately in both plankton and sediment trap samples in the Chukchi Sea area. These studies have shed light on new radiolarian taxa, especially within the order Entactinaria, including two new species of Joergensenium, Joergensenium arcticum from the western Arctic Ocean, so far restricted to the Pacific Winter Water in the Chukchi Sea, and Joergensenium clevei hitherto found in the northern part of the Norwegian Sea south of the Fram Strait. The taxonomic position of the order Entactinaria is discussed and the genus Joergensenium has been emended. We have also observed in detail the internal structure of J. arcticum using Microfocus X-ray Computed Tomography and have utilized three-dimensional imaging for the first time in a species description.
Resumo:
Tra le patologie ossee attualmente riconosciute, l’osteoporosi ricopre il ruolo di protagonista data le sua diffusione globale e la multifattorialità delle cause che ne provocano la comparsa. Essa è caratterizzata da una diminuzione quantitativa della massa ossea e da alterazioni qualitative della micro-architettura del tessuto osseo con conseguente aumento della fragilità di quest’ultimo e relativo rischio di frattura. In campo medico-scientifico l’imaging con raggi X, in particolare quello tomografico, da decenni offre un ottimo supporto per la caratterizzazione ossea; nello specifico la microtomografia, definita attualmente come “gold-standard” data la sua elevata risoluzione spaziale, fornisce preziose indicazioni sulla struttura trabecolare e corticale del tessuto. Tuttavia la micro-CT è applicabile solo in-vitro, per cui l’obiettivo di questo lavoro di tesi è quello di verificare se e in che modo una diversa metodica di imaging, quale la cone-beam CT (applicabile invece in-vivo), possa fornire analoghi risultati, pur essendo caratterizzata da risoluzioni spaziali più basse. L’elaborazione delle immagini tomografiche, finalizzata all’analisi dei più importanti parametri morfostrutturali del tessuto osseo, prevede la segmentazione delle stesse con la definizione di una soglia ad hoc. I risultati ottenuti nel corso della tesi, svolta presso il Laboratorio di Tecnologia Medica dell’Istituto Ortopedico Rizzoli di Bologna, mostrano una buona correlazione tra le due metodiche quando si analizzano campioni definiti “ideali”, poiché caratterizzati da piccole porzioni di tessuto osseo di un solo tipo (trabecolare o corticale), incluso in PMMA, e si utilizza una soglia fissa per la segmentazione delle immagini. Diversamente, in casi “reali” (vertebre umane scansionate in aria) la stessa correlazione non è definita e in particolare è da escludere l’utilizzo di una soglia fissa per la segmentazione delle immagini.
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
The imaging findings of a case of metastasing meningioma are described. The case illustrates a number of rare and interesting features. The patient presented with haemoptysis 22 years after the initial resection of an intracranial meningioma. CT demonstrated heterogeneous masses with avid peripheral enhancement without central enhancement. Blood supply to the larger lesion was partially from small feeding vessels from the inferior pulmonary vein. These findings correlate with a previously published case in which there was avid uptake of fluoro-18-deoxyglucose peripherally with lesser uptake centrally. The diagnosis of metastasing meningioma was confirmed on percutaneous lung tissue biopsy.