986 resultados para Evaluate image retention
Resumo:
This letter presents a lossless data hiding scheme for digital images which uses an edge detector to locate plain areas for embedding. The proposed method takes advantage of the well-known gradient adjacent prediction utilized in image coding. In the suggested scheme, prediction errors and edge values are first computed and then, excluding the edge pixels, prediction error values are slightly modified through shifting the prediction errors to embed data. The aim of proposed scheme is to decrease the amount of modified pixels to improve transparency by keeping edge pixel values of the image. The experimental results have demonstrated that the proposed method is capable of hiding more secret data than the known techniques at the same PSNR, thus proving that using edge detector to locate plain areas for lossless data embedding can enhance the performance in terms of data embedding rate versus the PSNR of marked images with respect to original image.
Resumo:
Peer-reviewed
Resumo:
Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.
Resumo:
The objective of this work was to evaluate the seasonal variation of soil cover and rainfall erosivity, and their influences on the revised universal soil loss equation (Rusle), in order to estimate watershed soil losses in a temporal scale. Twenty-two TM Landsat 5 images from 1986 to 2009 were used to estimate soil use and management factor (C factor). A corresponding rainfall erosivity factor (R factor) was considered for each image, and the other factors were obtained using the standard Rusle method. Estimated soil losses were grouped into classes and ranged from 0.13 Mg ha-1 on May 24, 2009 (dry season) to 62.0 Mg ha-1 on March 11, 2007 (rainy season). In these dates, maximum losses in the watershed were 2.2 and 781.5 Mg ha-1 , respectively. Mean annual soil loss in the watershed was 109.5 Mg ha-1 , but the central area, with a loss of nearly 300.0 Mg ha-1 , was characterized as a site of high water-erosion risk. The use of C factor obtained from remote sensing data, associated to corresponding R factor, was fundamental to evaluate the soil erosion estimated by the Rusle in different seasons, unlike of other studies which keep these factors constant throughout time.
Resumo:
Background: We examined one's own body image perception and its association with reported weight-related behavior among adolescents of a rapidly developing country in the African region. Methods: We conducted a school-based survey of 1432 students aged 11-17 years in the Seychelles. Weight and height were measured, and thinness, normal weight and overweight were assessed along standard criteria. A self-administered and anonymous questionnaire was administered. Perception of body image was assessed using both a closed-ended question (CEQ) and the Stunkard's pictorial silhouettes (SPS). Finally, a question assessed voluntary attempts to change weight. Results: Overall, 14.1% of the students were thin, 63.9% were normal-weight, and 22.0% were overweight or obese. There was fair agreement between actual weight status and self-perceived body image based on either CEQ or SPS. However, a substantial proportion of the overweight students did not consider themselves as overweight (SPS: 24%, CEQ: 34%) and, inversely, a substantial proportion of the normal-weight students considered themselves as too thin (SPS: 29%, CEQ: 15%). Among the overweight students, an adequate attempt to lose weight was reported more often by boys and girls who perceived themselves as overweight vs. not overweight (72-88% vs. 40-71%, p <0.05 for most comparisons). Among the normal-weight students, an inadequate attempt to gain weight was reported more often by boys and girls who perceived themselves as thin vs. not thin (27-68% vs. 11-19%, p <0.05). Girls had leaner own body ideals than boys. Conclusions: We found that substantial proportions of overweight students did not perceive themselves as overweight and/or did not want to lose weight and, inversely, that many normalweight students perceived themselves as too thin and/or wanted to gain weight: this points to forces that can drive the upwards overweight trends. Appropriate perception of one's weight was associated with adequate weight-control behavior, although not strongly, emphasizing that appropriate weight perception is only one of several factors driving adequate weight-related behavior. These findings emphasize the need to address appropriate perception of one's own weight and adequate weight-related behavior in adolescents for both individual and community weight-related interventions.
Resumo:
RESUME Les fibres textiles sont des produits de masse utilisés dans la fabrication de nombreux objets de notre quotidien. Le transfert de fibres lors d'une action délictueuse est dès lors extrêmement courant. Du fait de leur omniprésence dans notre environnement, il est capital que l'expert forensique évalue la valeur de l'indice fibres. L'interprétation de l'indice fibres passe par la connaissance d'un certain nombre de paramètres, comme la rareté des fibres, la probabilité de leur présence par hasard sur un certain support, ainsi que les mécanismes de transfert et de persistance des fibres. Les lacunes les plus importantes concernent les mécanismes de transfert des fibres. A ce jour, les nombreux auteurs qui se sont penchés sur le transfert de fibres ne sont pas parvenus à créer un modèle permettant de prédire le nombre de fibres que l'on s'attend à retrouver dans des circonstances de contact données, en fonction des différents paramètres caractérisant ce contact et les textiles mis en jeu. Le but principal de cette recherche est de démontrer que la création d'un modèle prédictif du nombre de fibres transférées lors d'un contact donné est possible. Dans le cadre de ce travail, le cas particulier du transfert de fibres d'un tricot en laine ou en acrylique d'un conducteur vers le dossier du siège de son véhicule a été étudié. Plusieurs caractéristiques des textiles mis en jeu lors de ces expériences ont été mesurées. Des outils statistiques (régression linéaire multiple) ont ensuite été utilisés sur ces données afin d'évaluer l'influence des caractéristiques des textiles donneurs sur le nombre de fibres transférées et d'élaborer un modèle permettant de prédire le nombre de fibres qui vont être transférées à l'aide des caractéristiques influençant significativement le transfert. Afin de faciliter la recherche et le comptage des fibres transférées lors des expériences de transfert, un appareil de recherche automatique des fibres (liber finder) a été utilisé dans le cadre de cette recherche. Les tests d'évaluation de l'efficacité de cet appareil pour la recherche de fibres montrent que la recherche automatique est globalement aussi efficace qu'une recherche visuelle pour les fibres fortement colorées. Par contre la recherche automatique perd de son efficacité pour les fibres très pâles ou très foncées. Une des caractéristiques des textiles donneurs à étudier est la longueur des fibres. Afin de pouvoir évaluer ce paramètre, une séquence d'algorithmes de traitement d'image a été implémentée. Cet outil permet la mesure de la longueur d'une fibre à partir de son image numérique à haute résolution (2'540 dpi). Les tests effectués montrent que les mesures ainsi obtenues présentent une erreur de l'ordre du dixième de millimètre, ce qui est largement suffisant pour son utilisation dans le cadre de cette recherche. Les résultats obtenus suite au traitement statistique des résultats des expériences de transfert ont permis d'aboutir à une modélisation du phénomène du transfert. Deux paramètres sont retenus dans le modèle: l'état de la surface du tissu donneur et la longueur des fibres composant le tissu donneur. L'état de la surface du tissu est un paramètre tenant compte de la quantité de fibres qui se sont détachées de la structure du tissu ou qui sont encore faiblement rattachées à celle-ci. En effet, ces fibres sont les premières à se transférer lors d'un contact, et plus la quantité de ces fibres par unité de surface est importante, plus le nombre de fibres transférées sera élevé. La longueur des fibres du tissu donneur est également un paramètre important : plus les fibres sont longues, mieux elles sont retenues dans la structure du tissu et moins elles se transféreront. SUMMARY Fibres are mass products used to produce numerous objects encountered everyday. The transfer of fibres during a criminal action is then very common. Because fibres are omnipresent in our environment, the forensic expert has to evaluate the value of the fibre evidence. To interpret fibre evidence, the expert has to know some parameters as frequency of fibres,' probability of finding extraneous fibres by chance on a given support, and transfer and persistence mechanisms. Fibre transfer is one of the most complex parameter. Many authors studied fibre transfer mechanisms but no model has been created to predict the number of fibres transferred expected in a given type of contact according to parameters as characteristics of the contact and characteristics of textiles. The main purpose of this research is to demonstrate that it is possible to create a model to predict the number of fibres transferred during a contact. In this work, the particular case of the transfer of fibres from a knitted textile in wool or in acrylic of a driver to the back of a carseat has been studied. Several characteristics of the textiles used for the experiments were measured. The data obtained were then treated with statistical tools (multiple linear regression) to evaluate the influence of the donor textile characteristics on the number of úbers transferred, and to create a model to predict this number of fibres transferred by an equation containing the characteristics having a significant influence on the transfer. To make easier the searching and the counting of fibres, an apparatus of automatic search. of fibers (fiber finder) was used. The tests realised to evaluate the efficiency of the fiber finder shows that the results obtained are generally as efficient as for visual search for well-coloured fibres. However, the efficiency of automatic search decreases for pales and dark fibres. One characteristic of the donor textile studied was the length of the fibres. To measure this parameter, a sequence of image processing algorithms was implemented. This tool allows to measure the length of a fibre from it high-resolution (2'540 dpi) numerical image. The tests done shows that the error of the measures obtained are about some tenths of millimetres. This precision is sufficient for this research. The statistical methods applied on the transfer experiment data allow to create a model of the transfer phenomenon. Two parameters are included in the model: the shedding capacity of the donor textile surface and the length of donor textile fibres. The shedding capacity of the donor textile surface is a parameter estimating the quantity of fibres that are not or slightly attached to the structure of the textile. These fibres are easily transferred during a contact, and the more this quantity of fibres is high, the more the number of fibres transferred during the contact is important. The length of fibres is also an important parameter: the more the fibres are long, the more they are attached in the structure of the textile and the less they are transferred during the contact.
Resumo:
Orgaanisten yhdisteiden negatiivinen retentio nanosuodatuksessa on ilmiö, jota eiole kovin paljon tutkittu. Negatiivisen retentioon vaikuttavat syyt tai tekijäteivät ole kovin hyvin tiedossa. Erotusmenetelmänä negatiivinen retentio voi olla käyttökelpoinen tietyissä sovelluksissa. Työn kirjallisuusosa käsittelee nanosuodatuksen erotusmekanismeja ja retentioon vaikuttavia tekijöitä. Myös joitakin malleja on esitetty. Nanosuodatus on monimutkainen prosessi, josta ei voida löytää vain yhtä erotusmekanismia tai retentioon vaikuttavaa tekijää. Prosessit ovat kokonaisuuksia, joissa erottumiseen vaikuttavat syöttöliuoksen, erotettavan komponentin ja kalvon ominaisuudet, ja niiden väliset vuorovaikutukset. Työn kokeellisessa osassa koottiin mahdollisimman paljon esimerkkejä, joissa monosakkaridien negatiivinen retentio ilmenee. Muita orgaanisia ja epäorgaanisia yhdisteitä käytettiin 'häiriöyhdisteinä' syöttöliuoksessa monosakkaridien kanssa. Kokeet suoritettiin kahdella laboratoriomittakaavan suodatuslaitteella käyttäen kahta kaupallista nanosuodatuskalvoa. Negatiivinen retentio ilmeni useissa tapauksissa. Permeaattivuon ja 'häiriöyhdisteiden' pitoisuuksien havaittiin vaikuttavan voimakkaasti negatiivisen retention ilmenemiseen.
Resumo:
PURPOSE OF REVIEW: Recent findings in the physiology and neurobiology of ejaculation have expanded our understanding of male sexual function and have allowed the development of new instruments to investigate ejaculatory and orgasmic disorders. RECENT FINDINGS: The evidence-based definition of lifelong premature ejaculation has set a model in the evaluation and treatment outcome of sexual dysfunction. New instruments to objectively assess arousal, orgasm and the expulsion phase of ejaculation such as functional MRI, dynamic pelvic ultrasound, PET scans and validated questionnaires have lead to a better understanding of sexual dysfunction in men. Animal models, developments in neurobiology and clinical experience have transformed a purely psychoanalytical approach to ejaculatory and orgasmic function into a novel multidisciplinary, scientifically sound and evidence-based discipline of medicine. SUMMARY: Ejaculation is an integral part of normal sexual function. Ejaculatory dysfunction is common and may cause substantial disruption to the quality of a patient's life. A better understanding of the epidemiology, pathophysiology, neuroscience and genetics of ejaculatory and orgasmic function will eventually lead to the development of new, effective methods of treatment of disorders of ejaculation and orgasm in men.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
Image filtering is a highly demanded approach of image enhancement in digital imaging systems design. It is widely used in television and camera design technologies to improve the quality of an output image to avoid various problems such as image blurring problem thatgains importance in design of displays of large sizes and design of digital cameras. This thesis proposes a new image filtering method basedon visual characteristics of human eye such as MTF. In contrast to the traditional filtering methods based on human visual characteristics this thesis takes into account the anisotropy of the human eye vision. The proposed method is based on laboratory measurements of the human eye MTF and takes into account degradation of the image by the latter. This method improves an image in the way it will be degraded by human eye MTF to give perception of the original image quality. This thesis gives a basic understanding of an image filtering approach and the concept of MTF and describes an algorithm to perform an image enhancement based on MTF of human eye. Performed experiments have shown quite good results according to human evaluation. Suggestions to improve the algorithm are also given for the future improvements.
Resumo:
The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.
Resumo:
We study the impact of sampling theorems on the fidelity of sparse image reconstruction on the sphere. We discuss how a reduction in the number of samples required to represent all information content of a band-limited signal acts to improve the fidelity of sparse image reconstruction, through both the dimensionality and sparsity of signals. To demonstrate this result, we consider a simple inpainting problem on the sphere and consider images sparse in the magnitude of their gradient. We develop a framework for total variation inpainting on the sphere, including fast methods to render the inpainting problem computationally feasible at high resolution. Recently a new sampling theorem on the sphere was developed, reducing the required number of samples by a factor of two for equiangular sampling schemes. Through numerical simulations, we verify the enhanced fidelity of sparse image reconstruction due to the more efficient sampling of the sphere provided by the new sampling theorem.
Resumo:
In this paper, we consider active sampling to label pixels grouped with hierarchical clustering. The objective of the method is to match the data relationships discovered by the clustering algorithm with the user's desired class semantics. The first is represented as a complete tree to be pruned and the second is iteratively provided by the user. The active learning algorithm proposed searches the pruning of the tree that best matches the labels of the sampled points. By choosing the part of the tree to sample from according to current pruning's uncertainty, sampling is focused on most uncertain clusters. This way, large clusters for which the class membership is already fixed are no longer queried and sampling is focused on division of clusters showing mixed labels. The model is tested on a VHR image in a multiclass classification setting. The method clearly outperforms random sampling in a transductive setting, but cannot generalize to unseen data, since it aims at optimizing the classification of a given cluster structure.
Resumo:
The topic of this thesis is studying how lesions in retina caused by diabetic retinopathy can be detected from color fundus images by using machine vision methods. Methods for equalizing uneven illumination in fundus images, detecting regions of poor image quality due toinadequate illumination, and recognizing abnormal lesions were developed duringthe work. The developed methods exploit mainly the color information and simpleshape features to detect lesions. In addition, a graphical tool for collecting lesion data was developed. The tool was used by an ophthalmologist who marked lesions in the images to help method development and evaluation. The tool is a general purpose one, and thus it is possible to reuse the tool in similar projects.The developed methods were tested with a separate test set of 128 color fundus images. From test results it was calculated how accurately methods classify abnormal funduses as abnormal (sensitivity) and healthy funduses as normal (specificity). The sensitivity values were 92% for hemorrhages, 73% for red small dots (microaneurysms and small hemorrhages), and 77% for exudates (hard and soft exudates). The specificity values were 75% for hemorrhages, 70% for red small dots, and 50% for exudates. Thus, the developed methods detected hemorrhages accurately and microaneurysms and exudates moderately.