942 resultados para Enrique IV, Rey de Castilla
Resumo:
Recent R-matrix calculations of electron impact excitation rates in Ar IV are used to calculate the emission-line ratio: ratio diagrams (R1, R2), (R1, R3), and (R1, R4), where K1 = I(4711 Å)/I(4740 Å), R2 = I(7238 Å)/I(4711 + 4740 Å), R3 = I(7263 Å)/I(4711 + 4740 Å), and R4 = I(7171 Å)/I(4711 + 4740 Å), for a range of electron temperatures (Te = 5000-20,000 K) and electron densities (Ne = 10-106 cm-3) appropriate to gaseous nebulae. These diagrams should, in principle, allow the simultaneous determination of Te and Ne from measurements of the [Ar IV] lines in a spectrum. Plasma parameters deduced for a sample of planetary nebulae from (R1, R3) and (R1, R4), using observational date obtained with the Hamilton echelle spectrograph on the 3 m Shane Telescope at the Lick Observatory, are found to show excellent internal consistency and to be in generally good agreement with the values of Te and Ne estimated from other line ratios in the echelle spectra. These results provide observational support for the accuracy of the theoretical ratios and, hence, the atomic data adopted in their derivation. In addition, they imply that the 7171 Å line is not as seriously affected by telluric absorption as previously thought. However, the observed values of R2 are mostly larger than the theoretical high-temperature and density limit, which is due to blending of the Ar IV 7237.54 Å line with the strong C II transition at 7236 Å.
Resumo:
Background: Nateglinide restores early-phase insulin secretion to feeding and reduces postprandial hyperglycaemia in type 2 diabetes. This study evaluated the effects of nateglinide on dipeptidyl peptidase-IV (DPP-IV) activity and glucose-dependent insulinotropic polypeptide (GIP) degradation
Resumo:
Background In recent years there has been an increase in the provision of conscious sedation, which is said to be a safe and effective means of managing the anxious patient. However, there are no guidelines to aid the dental practitioner in assessing the patient's need for sedation based on their level of anxiety.
Aims and methods The present study investigated the importance of patient anxiety as an indicator for IV sedation, using focus groups to inform the development of narrative vignettes. Ninety-nine practitioners responded to a series of scenarios to determine whether the level of patient anxiety and the patient's demand for IV sedation influenced their decision making.
Results Level of dental anxiety had a stronger influence on the clinician's decision making than patient demand, with increasing levels of dental anxiety being positively associated with the likelihood of clinicians indicating a need for IV patient sedation and also, the likelihood of clinicians providing IV sedation to these patients. Only 14% (n = 14) of respondents reported formally assessing dental anxiety.
Conclusions While dental anxiety is considered to be a key factor in determining the need for IV sedation, there is a lack of guidance regarding the assessment of anxiety among patients.
Resumo:
The oxidation of six charged iron(III) tetraarylporphyrins with chemical oxidants has been investigated. In aqueous solution each can be converted by tert-butyl hydroperoxide or monopersulphate into its corresponding oxoiron(IV) porphyrin, whereas in methanol only the iron(III) tetra(N-methylpyridyl)porphyrins form detectable ferryl porphyrins at ambient temperatures. On standing, the iron species revert to the parent porphyrin with a small loss due to non-reversible oxidative destruction. That the oxidised porphyrin intermediates are oxoiron(IV) species has been determined using UV-VIS, resonance Raman, H1 NMR and EPR spectroscopy.
Resumo:
We report calculations for energy levels, radiative rates and electron impact excitation rates for transitions in He-like Li II, Be III, B IV and C V. grasp (general-purpose relativistic atomic structure package) is adopted for calculating energy levels and radiative rates. For determining the collision strengths and subsequently the excitation rates, the Dirac atomic R-matrix code (darc) is used. Oscillator strengths, radiative rates and line strengths are reported for all E1, E2, M1 and M2 transitions among the lowest 49 levels of each ion. Collision strengths have been averaged over a Maxwellian velocity distribution and the effective collision strengths so obtained are reported over a wide temperature range up to 10(6) K. Comparisons have been made with similar data obtained from the flexible atomic code (FAC) to highlight the importance of resonances, included in calculations from darc, in the determination of effective collision strengths. Discrepancies between the collision strengths from darc and fac, particularly for weak transitions and at low energies, have also been discussed. Additionally, lifetimes are also listed for all calculated levels of the above four ions.
Resumo:
A description of the radiation emitted by impurities from within a plasma is crucial if spectral line intensities are to be used in detailed studies, such as the analysis of impurity transport. The simplest and most direct check that can be made on measurements of line intensities is to analyse their ratios with other lines from the same ion. This avoids uncertainties in determining the volume of the emitting plasma and the absolute sensitivity calibration of the spectrometer and, in some cases, the need even for accurate measurements of parameters such as electron density. Consistency is required between the measured line intensity ratios and the theoretical values. The expected consistency has not been found for radiation emitted from the JET scrape-off layer (e.g. Lawson et al 2009a JINST 4 P04013), meaning that the description of the spectral line intensities of impurity emission from the plasma edge is incomplete. In order to gain further understanding of the discrepancies, an analysis has been carried out for emission from the JET divertor plasma and this is reported in this paper. Carbon was the main low Z intrinsic impurity in JET and an analysis of spectral line intensity ratios has been made for the C (IV) radiation emitted from the JET divertor. In this case, agreement is found between the measured and theoretical ratios to a very high accuracy, namely to within the experimental uncertainty of similar to +/- 10%. This confirms that the description of the line intensities for the present observations is complete. For some elements and ionization stages, an analysis of line intensity ratios can lead to the determination of parameters such as the electron temperature of the emitting plasma region and estimates of the contribution of recombination to the electron energy level populations. This applies to C (IV) and, to show the value and possibilities of the spectral measurements, these parameters have been calculated for a database of Ohmic and additionally heated phases of a large number of pulses. The importance of dielectronic, radiative and charge-exchange recombination as well as ionization has been investigated. In addition, the development of T-e throughout two example discharges is illustrated. The presented results indicate a number of areas for further investigation.
Resumo:
A UVB specific dosimeter is described comprising: a redox dye (2,6-dichloroindophenol, DCIP), a semiconductor ( tin(IV) oxide, SnO2) and a sacrificial electron donor ( glycerol) dispersed in a polymer ( hydroxy ethyl cellulose, HEC) film. The dosimeter is blue in the absence of UVB light but rapidly loses colour on exposure to UVB light. The spectral characteristics of a typical UVB dosimeter film and the mechanism by which the colour change occurs are detailed. DCIP UVB dosimeter films exhibit a response that is related to the irradiance level and duration of UVB exposure, the level of SnO2 present and to a lesser extent the level of glycerol present. The response of the dosimeter appears to be independent of dye concentration and film thickness. Furthermore, DCIP UVB dosimeter films respond to solar simulated light, exhibiting a colour loss that can be simply related to the Minimal Erythemal Dose (MED) exposure for skin type II. As a consequence, such indicators have potential for measuring solar radiation exposure and providing an early warning of erythema for most Caucasian skin (i.e. skin type II).