927 resultados para Endovascular Presence
Resumo:
OBJECTIVES: To evaluate the influence of secondary infection on major amputation in chronic critical leg ischemia (CLI). DESIGN: Prospective, controlled observational study. MATERIALS AND METHODS: Sixty-seven patients with CLI and ischemic lesions participated in the study. Presence of infection was defined by clinical, laboratory and radiological criteria. Patients were categorized as having no local infection, soft tissue infection or osteomyelitis treated without antibiotics, amoxicillin/clavulanacid for 1 month or ciprofloxacin and clindamycin for 3 months, respectively. Clinical outcome was assessed at 2, 6 and 12 months. Study endpoints were major amputation and mortality. Analyses were performed using the Kaplan-Meier method. RESULTS: Forty-seven of 67 patients had a local infection. Major amputation was lower in patients with successful revascularization as compared to patients unsuitable for or with failed (without) revascularization (0% vs 26%, p<0.01). In patients with successful revascularization the probability of complete healing was lower with secondary infection (23% vs 71%, p=0.03). In patients without revascularization complete healing was rare (<10%), but secondary infection did not influenced major amputation, mortality or serious adverse events. CONCLUSION: Secondary infection reduces the likelihood of successful healing following revascularisation of CLI.
Resumo:
In evaluating the accuracy of diagnosis tests, it is common to apply two imperfect tests jointly or sequentially to a study population. In a recent meta-analysis of the accuracy of microsatellite instability testing (MSI) and traditional mutation analysis (MUT) in predicting germline mutations of the mismatch repair (MMR) genes, a Bayesian approach (Chen, Watson, and Parmigiani 2005) was proposed to handle missing data resulting from partial testing and the lack of a gold standard. In this paper, we demonstrate an improved estimation of the sensitivities and specificities of MSI and MUT by using a nonlinear mixed model and a Bayesian hierarchical model, both of which account for the heterogeneity across studies through study-specific random effects. The methods can be used to estimate the accuracy of two imperfect diagnostic tests in other meta-analyses when the prevalence of disease, the sensitivities and/or the specificities of diagnostic tests are heterogeneous among studies. Furthermore, simulation studies have demonstrated the importance of carefully selecting appropriate random effects on the estimation of diagnostic accuracy measurements in this scenario.
Resumo:
PURPOSE: To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS: Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS: IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS: The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.
Resumo:
The treatment of complex aortic pathologies involving the ascending aorta, the aortic arch, and the descending aorta remains a challenging issue in aortic surgery. The frozen elephant trunk procedure effectively combines surgical and interventional technologies in the treatment of extensive aortic aneurysms and dissections. We present two patients with complex aortic lesions involving all three segments of the thoracic aorta. The device used in our series is the new E-vita open hybrid prosthesis consisting of a proximal woven polyester tube and a distal self-expandable nitinol stent graft, which can be delivered antegrade into the descending aorta.
Resumo:
Endovascular therapy is a rapidly evolving field for the treatment of patients with peripheral arterial disease, and a magnitude of studies reporting on various modern revascularization concepts have been recently published. Thus, studies assessing the efficacy of endovascular therapy of peripheral arteries do not operate with uniformly defined endpoints, rendering a direct comparison of studies difficult. The purpose of this consensus statement is to highlight differences in the terminology used in the current literature and to propose some standardized criteria that must be considered when reporting results of endovascular revascularization for chronic ischaemia of lower limb arteries.
Resumo:
Abnormal morphology of the hip has been associated with primary osteoarthrosis. We evaluated the morphology of 464 consecutive hips contralateral to hips treated by THA. We excluded all hips with known diagnoses leading to secondary osteoarthritis and all hips with advanced arthrosis to eliminate the effect of arthritic remodeling on the morphologic measurements. Of the remaining 119 hips, 25 were in patients aged 60 years or older who had no or mild arthrosis (Tönnis Grade 0 or 1) and 94 hips had Tönnis Grade 2 osteoarthrosis. We quantified morphologic parameters on plain radiographs and CT images and simulated range of motion using virtual bone models from the CT data. The nonarthritic hips had fewer pathomorphologic findings. High alpha angles and high lateral center edge angles were strongly associated with the presence of arthritis; decreased internal and external rotation in 90 degrees flexion showed lesser correlation. The data confirm previous observations that abnormal hip morphology predates arthrosis and is not secondary to the osteoarthritic process. Hips at risk for developing arthrosis resulting from pathomorphologic changes may potentially be identified at the cessation of growth, long before the development of osteoarthrosis.
Resumo:
The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days +/- 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P = 0.005) compared to pre-EVAR measurements. One-month follow-up demonstrated a 47% decrease in systolic sac pressure (P = 0.05). On follow-up CT scans, the average maximum aneurysm diameter pre-EVAR was 6.3 +/- 1.6 cm and post-EVAR 6.0 +/- 1.7 cm (P=0.05). The diameter of the aneurysm sac was larger only in one patient with a type-III endoleak. Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans.