953 resultados para Emergency water supply
Resumo:
The south region of São Paulo city hosts the Guarapiranga dam, responsible for water supply to 25% of the city population. Their surroundings have been subject to intense and irregular occupation by people from very low socioeconomics classes. Measurements undertaken on sediment and particulate materials in the dam revealed concentrations of lead. copper, zinc and cadmium above internationally accepted limits. Epidemiological and toxicological studies undertaken by the World Health Organization in individuals exhibiting lead concentrations in blood, near or below the maximum recommended (10 mu g dl(-1)), surprisingly revealed that toxic effects are more intense in individuals belonging to low socioeconomics classes. Motivated by these facts, we aimed at the investigation of chronic incorporation of lead. as well as the use of our BIOKINETICS code, which is based on an accepted ICRP biokinetics model for lead, in order to extrapolate the results from teeth to other organs. The focus of our data taking was children from poor families, living in a small, restrict and allegedly contaminated area in São Paulo city. Thus, a total of 74 human teeth were collected. The average concentration of lead in teeth of children 5 to 10 years old was determined by means of a high-resolution inductively coupled plasma mass spectrometer (ICP-MS). For standardization of the measurements, an animal bone certified material (H-Animal Bone), from the International Atomic Energy Agency, was analyzed. The amount of lead in children living in the surroundings of the dam, was approximately 40% higher than those from the control region, and the average lead concentration was equal to 1.3 mu g g(-1) approximately. Grouping the results in terms of gender, tooth type and condition, it was concluded that a carious molar of boys is a much more efficient contamination pathway for lead, resulting in concentrations 70% higher than in the control region. We also inferred the average concentrations of lead in other organs of these children, by making use of our BIOKINETIC code. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Aiming to know the influence of the pluviometric precipitation over the physical chemical and bacteriological characteristics of the water coming from three sources of public supply, and to verify the probable origin of faecal contamination, tests of total coliforms, faecal coliforms, faecal streptococci and mesophilic microorganisms, as well as the determination of pH, temperature and turbidity of 156 water samples were done. The samples were taken from a stream, a drain and an artesian well, located in the city of Jaboticabal, SP, Brazil. The results obtained showed that the occurrence of pluviometric precipitation determined a significant increase of the number of total coliforms in the water samples from the stream. The use of the ratio CF/EF, indicate the probable origin of the faecal contamination only in the samples of the water coming from the stream, which were defined as being of human origin. In relation to the physical-chemical composition it was noticed that the influence of the pluviometric precipitation over the turbidity appeared to be higher and significant in the samples of water of the stream.
Resumo:
The first studies with constructed wetlands undertaken in Brazil were the result of observations made from the Amazon flood plains. The first attempt to use this capacity to change the quality of the water, in the sense of purification performed in Brazil using constructed wetland systems, was made by Salati et al. After that, new technologies were developed in a focused attempt to increase the efficiency of the system and reduce investments. Over these 18 years, persuading the Brazilian scientific community as well as the environmental control agencies to give due attention to this kind of research has required endless efforts. Only in recent years have major institutions responsible for sewage treatment and potable water supply been concerned with this type of technology for solving real problems. These institutions are as follows: SABESP (Basic Sanitation Company of Sao Paulo State), SANEPAR (Sanitation Company of Parana State) and CESP (Electric Company of Sao Paulo State). One of the private institutions that has systematically worked in the design and projects of constructed wetlands is the Institute of Applied Ecology. This institution has enhanced and developed a water depuration system based on the purifying capacity of the soil. The wetlands with filtering soils are systems formed by overlapping layers of crushed stone, gravel and soil planted with rice. This technology has been used in sewage treatment and also in water supply systems.
Resumo:
Riparian forest restoration projects in the Tropics are complex, demanding longterm research, continuous human efforts and correct use of financial resources. This paper presents an approach to rank priority areas for riparian forest restoration on the upper section of the Pardo River watershed, in São Paulo, Brazil, using remote sensing and GIS techniques. Pardo River watershed is specially important, since it is the major source of drinking water supply for the region and water for domestic and industrial use within Botucatu and surrounding. Results indicated that riparian restoration should involve 81,27% of the protected area and could be made in three phases, allocating resources according to a priority scale.
Resumo:
Activity profiles of excess 210Pb measured in four sediment cores from the Corumbataí River basin, São Paulo State, Brazil, provided an opportunity to evaluate sedimentation rates that are helpful for defining appropriate management strategies for the hydrological resources in the basin. This is because Rio Claro city and other municipalities make extensive use of surface waters for drinking water supply. The radiochemical analysis of the sediment cores yielded apparent sediment mass accumulation rates of between 406 and 1014 mg cm-2 year-1 for secondary drainage lines, whereas an intermediate value of 546 mg cm-2 year-1 was found in the Corumbataí River, the main drainage system of the studied area. These values provided estimates of average linear sedimentation rates of between 3.1 and 16.2 mm year-1 that are compatible with field evidence, with the highest value corresponding with an area characterized by accumulation of sediment.
Resumo:
This project has been developed to evaluate the possible relationship between the cesspit (pit latrine) in as far as it degrades the quality of underground water. Its importance is due to the fact that in the rural communities in the State of São Paulo (Brazil) this type of cesspit is very common as a means of sewage disposal and these communities use underground water for their supply of drinking water. Rural properties distributed over the rural area in the municipality of São José do Rio Preto were selected. A preliminary study was then set up to determine the social situation and health of the households as well as qualitative evaluations on the type of water supply and sewage disposal of these communities. Campaigns of water sampling then followed and laboratory analyses of water taken from wells were carried out. Parameters were set up to evaluate the potability according to Brazilian legislation (2004) paying attention to microbiologic (coliforms, Crytosporidium sp., and adenovirus). The analyses showed evidence of possible interaction between the wells and the sewage effluents and drainage in these communities. A PCR reaction to detect adenovirus showed a presence in 53.3% of the samples. The tests for the detection of Cryotosporidium sp all showed a negative result.
Resumo:
This work had as objective verifies the water quality used for irrigation by the vegetables producers of Botucatu-SP area. They were interviewed 27 producers that sell vegetables in the street markets of Botucatu. Among these producers, ten were selected, being one of each place. Three samples of water of each source were collected. The main standard to evaluate the obtained results were the CONAMA Resolution (National Environment Council) N° 357, March 17, 2005, that it establishes the standard for water classification. The Electric Conductivity was evaluated of agreement value suggested by CETESB and the color was verified according to OMS (Health World Organization), for potable water due to CONAMA Resolution not to stipulate a value for classification. For the public health, just the coliformes and nitrate are the preoccupying variables for they be related with the incidence of diseases, so, the analyzed waters, 40% of them (A, F, H and J producers) offer some risk for the health of Botucatu population, second established standard for CONAMA. We can to conclude that in a general way, those waters, are in conditions no alarming, because they don't present values very different from those established by the legislation.
Resumo:
Purpose - This paper seeks to address the issue of persistent and widespread drought conditions during 2000 and 2001, which were the apparent cause of the decline of water levels in the reservoirs of Brazilian hydroelectric power plants. Design/methodology/approach - This issue is addressed here through a case study of the hydroclimatology of the Paraíba river basin, in Southeast Brazil, home to four large multi-purpose operational reservoirs. Findings - The data analysis shows that neither changes in the frequency nor magnitude of extreme hydrological events (droughts and floods) nor in annual rainfall amounts can be detected from the existing climate record. The explanation is consistent with the fact that the terrestrial water and energy cycles are tightly, and non-linearly, coupled through evapotranspiration. Research limitations/implications - Therefore small change in the seasonality of rainfall can have a significant impact on the basin's overall hydrologic regime, and thus on the availability of water resources. Originality/value - Often, adaptation and resilience to climate variability are discussed in the context of catastrophic events such as floods and droughts. This study suggests that a different type of impacts, those associated with subtle, yet persistent changes of seasonality in the terrestrial water cycle, cannot be ignored in studies of long-term sustainability of water resources. © Emerald Group Publishing Limited.
Resumo:
The sowing of soybean out of the conventional period is an option for the production of seeds with high physiological quality. On the other hand, this fact makes necessary the search for cultivars adapted to new environmental conditions. Therefore, additional research is needed to supply more information to producers related to the choice of the most suited cultivars with regard to high seed quality. This research was conducted in Selvíria, MS, Brazil in which the cultivars FT-2000, FT-Inaê, Embrapa 20 (Doko RC), CAC-1, IAC-17, IAC-18, IAC-19, IAC-8-2, FT-101, FT-109, MT/ BR 45 (Paiaguás), MT/BR 50 (Parecis), MT/BR 52 (Curió), MT/BR 53 (Tucano), MT/BR 47 (Canário), MT/BR 49 (Pioneira), BRSMT Uirapuru, BR Emgopa 314 (Garça Branca), MG/BR 46 (Conquista), FT-Estrela, FT-Cometa, Dourados, JAB-11, BR 9 (Savana), FT-Abyara, Embrapa 30 (Vale do Rio Doce), Embrapa 9 (Bays), Embrapa 31 (Mina), IAC-16; IAS 5, EMGOPA-304, and IAC-Foscarin 31 were studied. These cultivars were sown on June 5, 1998, and evaluated both for agronomic characteristics and the physiological potential of the seeds. The experimental units were arranged in the field according to a randomized complete block design with five replicates. The cultivars more adapted to the climatic conditions were Parecis, Bays, CAC-1, Garça Branca, Paiaguás, Pioneira, and IAC-16. It was concluded that winter sowing should start at the beginning of May, with water supply, since June was found to be too late.
Resumo:
An experiment with four treatments was carried out on the experimental area of ADEI to compare three methods of water use requirement: ETc (T1) - irrigation based on crop evapotranspiration (ETc); Tensiometers (T2 and T3) - irrigations were made through reading of tensiometers installed at 40 cm deep and, Control (T4) - only one irrigation to promote the seedlings emergence. Both Class A pan and soil water depletion methods presented good results when the crop was developed without restraint of water. The Katerji method can be utilized in conditions of water restriction. Irrigation frequency was more important than amount of applied water for higher yield.
Resumo:
The efficiency of systems composed of two species of floating aquatic macrophyte (Eichhornia crassipes and Pistia stratiotes) to treat effluents from shrimp culture was evaluated in this research. The effluent originated from a pond populated with Macrobrachium amazonicum. Treatment systems consisted of 12 experimental tanks with aquatic macrophyte and three tanks without plants (control). Water samples were collected from the fresh water supply and before and after passing through the treatment systems. There are no differences in the removal of nutrients between the two species. The higher nutrient removal was observed for total phosphorus (41.9% by control; 71.6% by E. crassipes; 69.9 by P. stratiotes; 72.5% by E. crassipes + P. stratiotes and 72.1 by P. stratiotes + E. crassipes) and turbidity (30.6% by control; 80.2% by E. crassipes; 75.2 by P. stratiotes; 79.8% by E. crassipes + P. stratiotes and 81.5 by P. stratiotes + E. crassipes). The systems containing aquatic macrophytes were efficient in nitrogen and phosphorus removal from M. amazonicum culture. © 2008 Sociedade Brasileira de Zootecnia.
Resumo:
The need for a rational use of water and supply of food for a growing world population have led to the development of research in the area of irrigation systems. Thus, some irrigation systems which join efficiency with low cost of material have been developed. Although some technical characteristics are provided by the manufacturers, tests are required to verify functioning of the system and uniformity of water distribution. Continuous research on uniformity, characteristics of the materials and design of water distribution systems is essential for system improvement. Therefore, the objective of this work was to evaluate the CV (manufacturer's coefficient of variation) of Amanco microsprinkler (1.0 mm light green nipple) using bench testing in the laboratory of Irrigation at UNESP - FCA campus of Botucatu-SP. Twenty-five microsprinklers in a sequential design were used in the tests. Three flow systems were tested as follows: a Coil system based on serial connected pipes; a Lateral system, the most common system in which secondary lines are fed by a main line; and a Mesh system used in the urban water supply. The results showed that 4.17% CVf met the production standards and the Lateral and Mesh systems were similar regarding outflow using bench testing. The Mesh system presented the highest mean value of outflow and the lowest range of variation.
Resumo:
Purpose: To determine the prevalence of trachoma in Sao Gabriel da Cachoeira (SGC), the only urban community of the upper Rio Negro Basin of the Amazon state in Brazil, near the Colombian border, and to investigate the risk factors associated with the active forms of the disease. Methods: A total of 1702 people (440 children up to 9 years and 1069 adults aged 15 years and above) were examined. The sample was selected from a probabilistic household sampling procedure based on census data and a previous study of trachoma prevalence in Sao Gabriel da Cachoeira. A two-stage probabilistic household cluster sample was drawn. Household units were randomly selected within each cluster. A variety of socioeconomic and hygiene variables were studied in order to determine the risk factors for active trachoma in a household. Results: The total prevalence of trachoma was 8.9%. Prevalence of active trachoma (TF and/or TI) in children aged 1-9 years was 11.1% and trachomatous trichiasis in adults aged 15 years and above was 0.19%. Trachomatous scarring reached a peak of 22.4% for subjects between 50 to 60 years of age. Corneal opacity occurred in subjects aged 50 years and older with a prevalence of 2.0%. No sex effect was found on the overall prevalence of trachoma in SGC. Risk factors associated with active trachoma were mainly related to poor socioeconomic indicators. Conclusions: Despite the ubiquitous presence of water, the analysis of the risk factors associated with the active forms of the disease supports the idea that a low personal standard of hygiene and not water availability per se, is the key factor associated with trachoma. Copyright © 2008 Informa Healthcare USA, Inc.
Resumo:
This work introduces an innovative urinal for public convenience, that promotes at the same time water reuse and personal higiene, in a safe and economical way . Furthermore it demonstrates the latest technology and its technical and economical viabillity of utilization in new and already existing buildings facilities. This new model of personal higiene equipment offers as main benefits the improved economy with subsequent decrease in drinkable water consumption, sanitary safety, low cost and easy installation due to its simplicity and to the fact that it can be installed in already existing facilities. The proposal is constituted by a higienic, ecological and smart system for flushing of public urinals. It is a conjugated system of lavatory and urinal that reuses hands higienization water from the lavatory for flushing purpose. The proposed urinal can be operated manually or automatically by means of a presential sensor. The system promotes drinkable water economy by a rational utilization by avoiding the use of waste water from hand washing in place of clean water for flushing. The proposed equipment increases the economy of clean water in a simple and economical way and it can be installed in any type of public lavatory facilitie such as schools, public buildings, hospitals, commercial buildings, bus terminals, airports, stadiums, parking buildings and shopping centers. Additional benefits of the proposed system is the suggestion of hands washing before and after the use of the urinal without contamination risks from focet handling.and render more attractive the installation for a rational use of clean water in commercial and industrial buildings. Pay-back has shown to be very attractive for a number of internal return rates and also very attractive from the point of view of environmental protection.
Resumo:
This paper focuses on the drinking-water fluoridation process in Araçatuba region water supply systems by means of 5.157 fluoride concentration data from 2001 to 2005. These data were studied based on the water source, the administration and the structure of the water supply system, according to the population of the county and the type of management. Almost half of samples did not comply the fluoridation standard and the higher compliance was verified in the water supply systems operated by Sabesp (69%), followed by the group of Large counties (52%), statistically similar to the Medium ones (51.4%), and better than the Small ones (28%). The systems with surface intakes showed statistically higher performance in the compliance to the standard (60%) compared to the ones that use groundwater (42.9%). In this last group, those that explore the Guarani aquifer were superior (52.3%) than the others (46.6%).