879 resultados para Electricity generation performance test
Resumo:
Climate change is expected to have significant impact on the future thermal performance of buildings. Building simulation and sensitivity analysis can be employed to predict these impacts, guiding interventions to adapt buildings to future conditions. This article explores the use of simulation to study the impact of climate change on a theoretical office building in the UK, employing a probabilistic approach. The work studies (1) appropriate performance metrics and underlying modelling assumptions, (2) sensitivity of computational results to identify key design parameters and (3) the impact of zonal resolution. The conclusions highlight the importance of assumptions in the field of electricity conversion factors, proper management of internal heat gains, and the need to use an appropriately detailed zonal resolution. © 2010 Elsevier B.V. All rights reserved.
Resumo:
Purpose: This paper seeks to measure in a quantitative way the degree of alignment among a set of performance measures between two organizations. Design/methodology/approach: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. The authors applied the test and present coefficients of misalignment across three sets of measures: those used by a service provider involved in the research, those used by customers contracting the services, and those documented in 11 contracts studied. Findings: Results confirmed a high degree of alignment between target and actual operational performance in the contracts. The alignment of customers' financial objectives and contracts' operational metrics was low. Calculations show poor alignment between the objectives of the provider and the contribution received from the contracts. Research limitations/implications: Some limitations of the conclusions include the small sample of contracts used in the calculations. Further research should include not only actual contracts, but also failed ones. Practical implications: It is possible that misaligned goals, represented in misaligned performance measures, lead to tensions in intra-firm relationships. If these tensions are not addressed properly the relationship could be unstable or terminated prematurely. This method of measuring alignment could detect early potential dangers in intra-firm relationships. Originality/value: This paper extends Venkatraman's test of coalignment to assess the alignment of a set of performance measures governing a contractual inter-organizational relationship. Management researchers and business professionals may use this methodology when exploring degrees of alignment of performance measures in intra-functional and inter-firm relationships. © Emerald Group Publishing Limited.
Resumo:
A host of methods and tools to support designing are being developed in Cambridge EDC. These range from tools for design management to those for the generation and selection of design ideas, layouts, materials and production processes. A project, to develop a device to improve arm mobility of muscular dystrophy sufferers, is undertaken as a test-bed to evaluate and improve these methods and tools as well as to observe and modify its design and management processes. This paper presents the difficulties and advantages of using design methods and tools within this rehabilitation design context, with special focus on the evolution of the designs, tools, and management processes.
Resumo:
This paper presents an investigation of the mode-locking performance of a two-section external-cavity mode-locked InGaAs quantum-dot laser diode, focusing on repetition rate, pulse duration and pulse energy. The lowest repetition rate to-date of any passively mode-locked semiconductor laser diode is demonstrated (310 MHz) and a restriction on the pulse energy (at 0.4 pJ) for the shortest pulse durations is identified. Fundamental mode-locking from 310 MHz to 1.1 GHz was investigated, and harmonic mode-locking was achieved up to a repetition rate of 4.4 GHz. Fourier transform limited subpicosecond pulse generation was realized through implementation of an intra-cavity glass etalon, and pulse durations from 930fs to 8.3ps were demonstrated for a repetition rate of 1 GHz. For all investigations, mode-locking with the shortest pulse durations yielded constant pulse energies of ∼0.4 pJ, revealing an independence of the pulse energy on all the mode-locking parameters investigated (cavity configuration, driving conditions, pulse duration, repetition rate, and output power). © 2011 IEEE.
Resumo:
This paper considers next-generation optical datacommunication standards and discusses the types of modulation formats that are relevant. The performance of several schemes is considered over multimode fibre. The trade-offs between the different modulation formats are considered in terms of link length, receiver sensitivity and complexity of implementation. © 2011 IEEE.
Resumo:
Optimisation of cooling systems within gas turbine engines is of great interest to engine manufacturers seeking gains in performance, efficiency and component life. The effectiveness of coolant delivery is governed by complex flows within the stator wells and the interaction of main annulus and cooling air in the vicinity of the rim seals. This paper reports the development of a test facility which allows the interaction of cooling air and main gas paths to be measured at conditions representative of those found in modern gas turbine engines. The test facility features a two stage turbine with an overall pressure ratio of approximately 2.6:1. Hot air is supplied to the main annulus using a Rolls-Royce Dart compressor driven by an aero-derivative engine plant. Cooling air can be delivered to the stator wells at multiple locations and at a range of flow rates which cover bulk ingestion through to bulk egress. The facility has been designed with adaptable geometry to enable rapid changes of cooling air path configuration. The coolant delivery system allows swift and accurate changes to the flow settings such that thermal transients may be performed. Particular attention has been focused on obtaining high accuracy data, using a radio telemetry system, as well as thorough through-calibration practices. Temperature measurements can now be made on both rotating and stationary discs with a long term uncertainty in the region of 0.3 K. A gas concentration measurement system has also been developed to obtain direct measurement of re-ingestion and rim seal exchange flows. High resolution displacement sensors have been installed in order to measure hot running geometry. This paper documents the commissioning of a test facility which is unique in terms of rapid configuration changes, non-dimensional engine matching and the instrumentation density and resolution. Example data for each of the measurement systems is presented. This includes the effect of coolant flow rate on the metal temperatures within the upstream cavity of the turbine stator well, the axial displacement of the rotor assembly during a commissioning test, and the effect of coolant flow rate on mixing in the downstream cavity of the stator well. Copyright © 2010 by ASME.
Resumo:
Repeated daily treatment with the catecholamine-depleting agent, reserpine, dramatically reduced performance on the delayed response task, a test of spatial working memory that depends upon the integrity of the prefrontal cortex. Delayed response performance fell from an average of 27.2/30 trials correct before reserpine treatment to an average of 20.4/30 trials correct after repeated reserpine administration. Injection of the alpha2-adrenergic agonist, clonidine (0.0001-0.05 mg/kg), to chronic reserpine-treated monkeys significantly restored performance on the delayed response task; performance after an optimal dose averaged 27.8/30 trials correct. Clonidine's beneficial effects on delayed response performance were longlasting; monkeys remained improved for more than 24 h after a single clonidine injection. The finding that clonidine is efficacious in reserpinized animals supports the hypothesis that alpha2-adrenergic agonists improve cognitive function through actions at postsynaptic, alpha2-adrenergic receptors on non-adrenergic cells. In contrast to the delayed response task, reserpine had little effect on performance of a visual discrimination task, a reference memory task which does not depend on the prefrontal cortex. These results emphasize the importance of postsynaptic alpha2-adrenergic mechanisms in the regulation of working memory,
Resumo:
As a result of their morphology, nanowires bring new properties and the promise of performance for a range of electronic devices. This review looks into the properties of nanowires and the multiple ways in which they have been exploited for energy generation, from photovoltaics to piezoelectric generators. © 2012 IOP Publishing Ltd.
Resumo:
In recent years we have been developing a meshing system which is aimed at eliminating the bottleneck represented by building meshes for real-world, complex turbomachinery configurations. This system is based on a rapid octree meshing technology which is then made conformal to the bodies present. The objective of this paper is to demonstrate that this class of mesh is not only very fast to produce but also fit-for-purpose in the sense that simulations generated with third-party commercial flow solvers like Fluent have the same accuracy as those performed on more conventional meshes. A range of standard examples and test cases will be presented. Copyright © 2011 by ASME.