999 resultados para ELECTRON PUMP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical and structural characteristics of tantalum-titanium bilayers on silicon reacted by electron beam heating have been investigated over a wide range of temperature and time conditions. The reacted layers exhibit low sheet resistance and stable electrical characteristics up to at least 1100℃. Titanium starts reacting from 750℃ onwards for 100 milliseconds reaction times whereas tantalum starts reacting only above 900℃ for such short reaction times. RBS results confirm that silicon is the major diffusing species and there is no evidence for the formation of ternary silicides. Reactions have also been explored on millisecond time scales by non-isothermal heating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxygen vacancy has been inferred to be the critical defect in HfO 2, responsible for charge trapping, gate threshold voltage instability, and Fermi level pinning for high work function gates, but it has never been conclusively identified. Here, the electron spin resonance g tensor parameters of the oxygen vacancy are calculated, using methods that do not over-estimate the delocalization of the defect wave function, to be g xx = 1.918, g yy = 1.926, g zz = 1.944, and are consistent with an observed spectrum. The defect undergoes a symmetry lowering polaron distortion to be localized mainly on a single adjacent Hf ion. © 2012 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Space heating accounts for a large portion of the world's carbon dioxide emissions. Ground Source Heat Pumps (GSHPs) are a technology which can reduce carbon emissions from heating and cooling. GSHP system performance is however highly sensitive to deviation from design values of the actual annual energy extraction/rejection rates from/to the ground. In order to prevent failure and/or performance deterioration of GSHP systems it is possible to incorporate a safety factor in the design of the GSHP by over-sizing the ground heat exchanger (GHE). A methodology to evaluate the financial risk involved in over-sizing the GHE is proposed is this paper. A probability based approach is used to evaluate the economic feasibility of a hypothetical full-size GSHP system as compared to four alternative Heating Ventilation and Air Conditioning (HVAC) system configurations. The model of the GSHP system is developed in the TRNSYS energy simulation platform and calibrated with data from an actual hybrid GSHP system installed in the Department of Earth Science, University of Oxford, UK. Results of the analysis show that potential savings from a full-size GSHP system largely depend on projected HVAC system efficiencies and gas and electricity prices. Results of the risk analysis also suggest that a full-size GSHP with auxiliary back up is potentially the most economical system configuration. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a variation of the thermally actuated flux pump and the linear type magnetic flux pump (LTMFP), the circular type magnetic flux pump (CTMFP) device is proposed to magnetize a circular shape type-II superconducting thin film and bulk. The basic concept is the same as the thermally actuated flux pump: a circularly symmetric traveling magnetic field is generated below a circular shape superconductor to increase its trapping field. However, this traveling field is created by the three phase windings instead of heating gadolinium block. Apart from the LTMFP, the three phase windings are wound concentrically instead of linearly. The speed of the traveling field is controlled by the AC frequency and the magnitude of the field is controlled by the magnitudes of AC currents. In addition, a coil with DC current is wound around the three phase windings to provide a background field. The concept design is presented in this paper. The magnetic waveforms are analysed numerically by the COMSOL 3.5a software. The impedances of the three phase windings are calculated and a corresponding circuit design is presented. This rig can be used as an advanced tool to study the flux pump behavior of a circular shape superconductor. © 2002-2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superconductors have a bright future; they are able to carry very high current densities, switch rapidly in electronic circuits, detect extremely small perturbations in magnetic fields, and sustain very high magnetic fields. Of most interest to large-scale electrical engineering applications are the ability to carry large currents and to provide large magnetic fields. There are many projects that use the first property, and these have concentrated on power generation, transmission, and utilization; however, there are relatively few, which are currently exploiting the ability to sustain high magnetic fields. The main reason for this is that high field wound magnets can and have been made from both BSCCO and YBCO, but currently, their cost is much higher than the alternative provided by low-Tc materials such as Nb3Sn and NbTi. An alternative form of the material is the bulk form, which can be magnetized to high fields. This paper explains the mechanism, which allows superconductors to be magnetized without the need for high field magnets to perform magnetization. A finite-element model is presented, which is based on the E-J current law. Results from this model show how magnetization of the superconductor builds up cycle upon cycle when a traveling magnetic wave is induced above the superconductor. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents numerical analysis of the thermally actuated superconducting flux pump. Visualization of the behavior of the magnetic flux helps our understanding of flux injection mechanism. In addition, in order to confirm validity of the result, we conducted a preliminary flux pump experiment. This result qualitatively agrees well with the experimental one. The flux pump system utilizes a particular behavior that permeability of some materials such as Gadolinium is sensitive to the temperature. In this paper a simple heater is used to control the flux pump system. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of a superconducting flux pump is relatively straightforward. A small magnetic field repeatedly applied will lead to a much larger field being trapped within the superconductor. This field is limited by the volume of the superconductor and by its critical current but not by the excitation field. Here we will describe a new technique which facilitates the creation of high magnetic fields and where the magnitude of the trapped field is limited by the superconductor not the magnetising field. The technique is demonstrated using measurements taken using samples of bulk YBCO as YBCO has a very high irreversibility field and has the potential to trap high magnetic fields. The technique could be applied to other superconductors such as BSCCO or MgB2 and in other forms such as thin or thick films. © 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A circular-type magnetic flux pump (CTMFP) device was built to study the flux dynamics on a 2-inch-diameter YBCO thin film. This CTMFP is composed of two CTMFP coils, with each CTMFP coil containing concentric three-phase windings and a dc winding. We connected the three-phase windings to the output of a commercial inverter. By changing the output frequency of the inverter, the sweeping speed of the circular-shaped travelling magnetic wave can be changed. The connection of the phase coils follows the forward consequence, so that the circular-shaped travelling magnetic wave travels inward to the center. The output frequency f was changed from f = 0.01 to 1000.0 Hz. The YBCO sample was sandwiched between the two CTMFP coils to experience the circular-shaped travelling magnetic wave. It was found that the increase of the flux density in the center of the film is independent of the sweeping frequency. In high frequency f = 1000.0Hz, even if the waveform had changed a lot, the increment is still the same as in low frequencies. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron multiplication charge-coupled devices (EMCCD) are widely used for photon counting experiments and measurements of low intensity light sources, and are extensively employed in biological fluorescence imaging applications. These devices have a complex statistical behaviour that is often not fully considered in the analysis of EMCCD data. Robust and optimal analysis of EMCCD images requires an understanding of their noise properties, in particular to exploit fully the advantages of Bayesian and maximum-likelihood analysis techniques, whose value is increasingly recognised in biological imaging for obtaining robust quantitative measurements from challenging data. To improve our own EMCCD analysis and as an effort to aid that of the wider bioimaging community, we present, explain and discuss a detailed physical model for EMCCD noise properties, giving a likelihood function for image counts in each pixel for a given incident intensity, and we explain how to measure the parameters for this model from various calibration images. © 2013 Hirsch et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication and functionality of a 21 cm graphene-based transverse electron emission display panel is presented. A screen-printed triode edge electron emission geometry has been developed based on chemical vapor deposited (CVD) graphene supported on vertically aligned carbon nanotubes (CNT) necessary to minimize electrostatic shielding induced by the proximal bulk substrate. Integrated ZnO tetrapod electron scatterers have been shown to increase the emission efficiency by more than 90%. Simulated electron trajectories validate the observed emission characteristics with driving voltages less than 60 V. Fabricated display panels have shown real-time video capabilities that are hysteresis free (<0.2%), have extremely stable lifetimes (<3% variation over 10 h continuous operation) in addition to rapid temporal responses (<1 ms). © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermally actuated flux pump is an efficient method to magnetize the high-temperature superconductor (HTS) bulk without applying a strong magnetic field. A thermal material is employed as a magnetic switch, which decides the efficiency of the system. To measure the Curie temperatures of those samples without destroying them, the nondestructive Curie temperature (NDT) measurement was developed. The Curie temperature of gadolinium (Gd) was measured by the NDT method and compared to the results from superconducting quantum interference device (SQUID). Because the SQUID tests require the sample to be cut into small piece, a constant shape of the testing sample could not be guaranteed. The demagnetizing effect was considered to remove the shape effect. The intrinsic permeability was modified from the apparent susceptibility by considering demagnetization. A thermal material with low Curie temperature, Mg 0.15Cu0.15Zn0.7Ti0.04Fe 1.96O4, was synthesized and its performance was tested and compared with previous thermal materials. Comparisons of three thermal materials, including the Curie temperature and the permeability, will be detailed in the paper. © 2002-2011 IEEE.