967 resultados para Dynamic Contrast Enhanced Magnetic Resonance Imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We advocate the use of a novel compressed sensing technique for accelerating the magnetic resonance image acquisition process, coined spread spectrum MR imaging or simply s2MRI. The method resides in pre-modulating the signal of interest by a linear chirp, resulting from the application of quadratic phase profiles, before random k-space under-sampling with uniform average density. The effectiveness of the procedure is theoretically underpinned by the optimization of the coherence between the sparsity and sensing bases. The application of the technique for single coil acquisitions is thoroughly studied by means of numerical simulations as well as phantom and in vivo experiments on a 7T scanner. The corresponding results suggest a favorable comparison with state-of-the-art variable density k-space under-sampling approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dystonia is associated with impaired somatosensory ability. The electrophysiological method of repetitive transcranial magnetic stimulation (rTMS) can be used for noninvasive stimulation of the human cortex and can alter cortical excitability and associated behavior. Among others, rTMS can alter/improve somatosensory discrimation abilities, as shown in healthy controls. We applied 5Hz-rTMS over the left primary somatosensory cortex (S1) in 5 patients with right-sided writer's dystonia and 5 controls. We studied rTMS effects on tactile discrimination accuracy and concomitant rTMS-induced changes in hemodynamic activity measured by functional magnetic resonance imaging (fMRI). Before rTMS, patients performed worse on the discrimination task than controls even though fMRI showed greater task-related activation bilaterally in the basal ganglia (BG). In controls, rTMS led to improved discrimination; fMRI revealed this was associated with increased activity of the stimulated S1, bilateral premotor cortex and BG. In dystonia patients, rTMS had no effect on discrimination; fMRI showed similar cortical effects to controls except for no effects in BG. Improved discrimination after rTMS in controls is linked to enhanced activation of S1 and BG. Failure of rTMS to increase BG activation in dystonia may be associated with the lack of effect on sensory discrimination in this group and may reflect impaired processing in BG-S1 connections. Alternatively, the increased BG activation seen in the baseline state without rTMS may reflect a compensatory strategy that saturates a BG contribution to this task.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On the basis of MRI examinations in 88 neonates and infants with perinatal asphyxia, we defined 6 different patterns on T2-weighted images: pattern A--scattered hyperintensity of both hemispheres of the telencephalon with blurred border zones between cortex and white matter, indicating diffuse brain injury; pattern B--parasagittal hyperintensity extending into the corona radiata, corresponding to the watershed zones; pattern C--hyper- and hypointense lesions in thalamus and basal ganglia, which relate to haemorrhagic necrosis or iron deposition in these areas; pattern D--periventricular hyperintensity, mainly along the lateral ventricles, i.e. periventricular leukomalacia (PVL), originating from the matrix zone; pattern E--small multifocal lesions varying from hyper--to hypointense, interpreted as necrosis and haemorrhage; pattern F--periventricular centrifugal hypointense stripes in the centrum semiovale and deep white matter of the frontal and occipital lobes. Contrast was effectively inverted on T1-weighted images. Patterns A, B and C were found in 17%, 25% and 37% of patients, and patterns D, E and F in 19%, 17% and 35%, respectively. In 49 patients a combination of patterns was observed, but 30% of the initial images were normal. At follow-up, persistent abnormalities were seen in all children with patterns A and D, but in only 52% of those with pattern C. Myelination was retarded most often in patients with diffuse brain injury and PVL (patterns A and D).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The importance of the right ventricle as a determinant of clinical symptoms, exercise capacity, peri-operative survival and postoperative outcome has been underestimated for a long time. Right ventricular ejection fraction has been used as a measure of right ventricular function but has been found to be dependent on loading conditions, ventricular interaction as well as on myocardial structure. Altered left ventricular function in patients with valvular disease influences right ventricular performance mainly by changes in afterload but also by ventricular interaction. Right ventricular function and regional wall motion can be determined with right ventricular angiography, radionuclide ventriculography, two-dimensional echocardiography or magnetic resonance imaging. However, the complex structure of the right ventricle and its pronounced translational movements render quantification difficult. True regional wall motion analysis is, however, possible with myocardial tagging based on magnetic resonance techniques. With this technique a baso-apical shear motion of the right ventricle was observed which was enhanced in patients with aortic stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the diagnostic value of 18F-FDG PET/CT versus contrastenhanced CT in identifying chest wall invasion by NSCLC. Methods and Materials: The primary selection criterion was a peripheral tumor of any size with contact to the chest wall. A total of 25 patients with pathologically proven NSCLC satisfied these criteria. Chest wall invasion was interpreted upon PET/CT when a frank costal or intercostal 18F-FDG uptake was identified with or without concomitant morphologic alterations. On the other hand, the existence of periosteal rib reaction/erosion, chest wall thickening or obliteration of the pleural fat layer either separately or combined were considered essential diagnostic criteria for disease extension into the chest wall upon contrast-enhanced CT. The results were correlated with the final histological analysis. Results: Among the studied cohort, 13/25 (52%) patients had chest wall invasion consistent with T3 disease. Both PET/CT and contrast-enhanced CT successfully identified 12/13 (92%) of these patients. The single false-negative result was due to parietal pleural invasion. On the other hand, one false-positive result was encountered by PET/CT in a dyspneic patient; whereas, CT analysis revealed false-positive results in six patients. In these patients, periosteal rib reaction (n = 2) or asymmetric enlargement of adjacent chest wall muscles (n = 1) were identified along with an obliterated pleural fat layer (n = 6). The sensitivity, specificity, and accuracy of PET/CT and contrast-enhanced CT were 92, 91 and 92% versus 92, 50 and 72%. Conclusion: 18F-FDG PET/CT is an accurate diagnostic modality in identifying.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To describe low mechanical index grey scale contrast enhanced breast ultrasound in patients with intraductal echogenic material in the differentiation of papillomas from intraductal secretions. Methods and materials: In five patients with echographically detected ductal dilatation containing echogenic material low mechanical index grey scale contrast enhanced ultrasonography was performed. No patient had nipple discharge. The examination was performed with a 9 MHz linear transducer after injection of 4 ml of Sonovue. It was assessed if contrast enhancement was present or not. The results were correlated with histologic results after surgical resection or percutaneous biopsy when performed. Results: In 3 patients contrast enhancement was observed. These patients were operated and the papillomas confirmed by histology. In two patients no contrast enhancement was observed. In one of these two patients percutaneous biopsy was performed without evidence of a papillary lesion. The second patient presented with multiple dilated ducts containing echogenic material. No biopsy was performed but breast MRI showed no intraductal enhancement supporting the non papillary nature of the intraductal material. Conclusion: This pilot study shows that contrast enhanced ultrasound is able to detect the vascularisation of papillomas and that it may differentiate intraductal papillomas from secretions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of the SAOP potential for the calculation of NMR chemical shifts was evaluated. SAOP results show considerable improvement with respect to previous potentials, like VWN or BP86, at least for the carbon, nitrogen, oxygen, and fluorine chemical shifts. Furthermore, a few NMR calculations carried out on third period atoms (S, P, and Cl) improved when using the SAOP potential

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the University Medical Center, Swiss, from 2010 to 2012. Abundant evidence suggests that negative emotional stimuli are prioritized in the perceptual systems, eliciting enhanced neural responses in early sensory regions as compared with neutral information. This facilitated detection is generally paralleled by larger neural responses in early sensory areas, relative to the processing of neutral information. In this sense, the amygdala and other limbic regions, such as the orbitofrontal cortex, may play a critical role by sending modulatory projections onto the sensory cortices via direct or indirect feedback.The present project aimed at investigating two important issues regarding these mechanisms of emotional attention, by means of functional magnetic resonance imaging. In Study I, we examined the modulatory effects of visual emotion signals on the processing of task-irrelevant visual, auditory, and somatosensory input, that is, the intramodal and crossmodal effects of emotional attention. We observed that brain responses to auditory and tactile stimulation were enhanced during the processing of visual emotional stimuli, as compared to neutral, in bilateral primary auditory and somatosensory cortices, respectively. However, brain responses to visual task-irrelevant stimulation were diminished in left primary and secondary visual cortices in the same conditions. The results also suggested the existence of a multimodal network associated with emotional attention, presumably involving mediofrontal, temporal and orbitofrontal regions Finally, Study II examined the different brain responses along the low-level visual pathways and limbic regions, as a function of the number of retinal spikes during visual emotional processing. The experiment used stimuli resulting from an algorithm that simulates how the visual system perceives a visual input after a given number of retinal spikes. The results validated the visual model in human subjects and suggested differential emotional responses in the amygdala and visual regions as a function of spike-levels. A list of publications resulting from work in the host laboratory is included in the report.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the University Medical Center, Swiss, from 2010 to 2012. Abundant evidence suggests that negative emotional stimuli are prioritized in the perceptual systems, eliciting enhanced neural responses in early sensory regions as compared with neutral information. This facilitated detection is generally paralleled by larger neural responses in early sensory areas, relative to the processing of neutral information. In this sense, the amygdala and other limbic regions, such as the orbitofrontal cortex, may play a critical role by sending modulatory projections onto the sensory cortices via direct or indirect feedback.The present project aimed at investigating two important issues regarding these mechanisms of emotional attention, by means of functional magnetic resonance imaging. In Study I, we examined the modulatory effects of visual emotion signals on the processing of task-irrelevant visual, auditory, and somatosensory input, that is, the intramodal and crossmodal effects of emotional attention. We observed that brain responses to auditory and tactile stimulation were enhanced during the processing of visual emotional stimuli, as compared to neutral, in bilateral primary auditory and somatosensory cortices, respectively. However, brain responses to visual task-irrelevant stimulation were diminished in left primary and secondary visual cortices in the same conditions. The results also suggested the existence of a multimodal network associated with emotional attention, presumably involving mediofrontal, temporal and orbitofrontal regions Finally, Study II examined the different brain responses along the low-level visual pathways and limbic regions, as a function of the number of retinal spikes during visual emotional processing. The experiment used stimuli resulting from an algorithm that simulates how the visual system perceives a visual input after a given number of retinal spikes. The results validated the visual model in human subjects and suggested differential emotional responses in the amygdala and visual regions as a function of spike-levels. A list of publications resulting from work in the host laboratory is included in the report.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blunt chest traumas are a clinical challenge, both for diagnosis and treatment. The use ofCardiovascular Magnetic Resonance can play a major role in this setting. We present two cases: a12-year-old boy and 45-year-old man. Late gadolinium enhancement imaging enabled visualizationof myocardial damage resulting from the trauma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate magnetization transfer (MT) effects as a new source of contrast for imaging and tracking of peripheral foot nerves. MATERIALS AND METHODS: Two sets of 3D spoiled gradient-echo images acquired with and without a saturation pulse were used to generate MT ratio (MTR) maps of 260 μm in-plane resolution for eight volunteers at 3T. Scan parameters were adjusted to minimize signal loss due to T2 dephasing, and a dedicated coil was used to improve the inherently low signal-to-noise ratio of small voxels. Resulting MTR values in foot nerves were compared with those in surrounding muscle tissue. RESULTS: Average MTR values for muscle (45.5 ± 1.4%) and nerve (21.4 ± 3.1%) were significantly different (P < 0.0001). In general, the difference in MTR values was sufficiently large to allow for intensity-based segmentation and tracking of foot nerves in individual subjects. This procedure was termed MT-based 3D visualization. CONCLUSION: The MTR serves as a new source of contrast for imaging of peripheral foot nerves and provides a means for high spatial resolution tracking of these structures. The proposed methodology is directly applicable on standard clinical MR scanners and could be applied to systemic pathologies, such as diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Machine learning and pattern recognition methods have been used to diagnose Alzheimer's disease (AD) and mild cognitive impairment (MCI) from individual MRI scans. Another application of such methods is to predict clinical scores from individual scans. Using relevance vector regression (RVR), we predicted individuals' performances on established tests from their MRI T1 weighted image in two independent data sets. From Mayo Clinic, 73 probable AD patients and 91 cognitively normal (CN) controls completed the Mini-Mental State Examination (MMSE), Dementia Rating Scale (DRS), and Auditory Verbal Learning Test (AVLT) within 3months of their scan. Baseline MRI's from the Alzheimer's disease Neuroimaging Initiative (ADNI) comprised the other data set; 113 AD, 351 MCI, and 122 CN subjects completed the MMSE and Alzheimer's Disease Assessment Scale-Cognitive subtest (ADAS-cog) and 39 AD, 92 MCI, and 32 CN ADNI subjects completed MMSE, ADAS-cog, and AVLT. Predicted and actual clinical scores were highly correlated for the MMSE, DRS, and ADAS-cog tests (P<0.0001). Training with one data set and testing with another demonstrated stability between data sets. DRS, MMSE, and ADAS-Cog correlated better than AVLT with whole brain grey matter changes associated with AD. This result underscores their utility for screening and tracking disease. RVR offers a novel way to measure interactions between structural changes and neuropsychological tests beyond that of univariate methods. In clinical practice, we envision using RVR to aid in diagnosis and predict clinical outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past 20 years, BOLD fMRI has developed towards a central and fundamental tool in neuroscience. It has been shown that the BOLD response provides an indicator of neuronal activity in the brain. Consequently, for an accurate interpretation of findings in BOLD MRI experiments and to draw meaningful conclusions about the temporal evolution of neural events, a deep understanding of the nature of the BOLD contrast has become of essential importance. Since the dynamics of the major direct determinants of the BOLD signal (CBF, CBV and CMRO(2)) range between seconds and minutes, long duration stimulation was an early key strategy needed to study and understand the BOLD characteristics. This paper summarizes and discusses the thoughts and rationales of the long duration stimulation studies.