917 resultados para Dissolved air Flotation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of different cleaning media on the adhesion of resin cement to feldspathic ceramic after etching.Materials and Methods: The cementation surfaces of ceramic blocks (N = 20, n = 5 per group) were etched with 10% hydrofluoric acid (HF) gel for 20 s and rinsed for 60 s. They were then randomly assigned to 4 groups: G1: air-water spray+drying (control); G2: ultrasonic cleaning in distilled water for 4 min+drying; G3: ultrasonic cleaning in 99.5% acetone for 4 min+drying; G4: ultrasonic cleaning in 70% alcohol for 4 min+drying. The ceramic blocks were silanized and cemented (RelyX ARC) to the composite blocks. Subsequently, the microtensile bond strength test (mu TBS) was performed. In addition, EDS analysis was made to assess the elemental composition of the conditioned and cleaned ceramic surfaces.Results: A significantly higher mean mu TBS was obtained when specimens had been ultrasonically cleaned in distilled water (G2: 18.8 +/- 0.4 MPa) (p < 0.05) compared to other groups (G1: 16.6 +/- 0.5; G3: 16.1 +/- 0.9; G4: 15.8 +/- 1.4) (one-way ANOVA). EDS analysis indicated the presence of F- only in G1. Dissolved precipitates after HF etching were removed by ultrasonic cleaning.Conclusion: Cleaning the HF-etched ceramic surface ultrasonically in distilled water is recommended, instead of rinsing it with air-water spray only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No Córrego do Sapateiro, situado no Parque Municipal do Ibirapuera, na cidade de São Paulo, SP, Brasil, amostras de água (50 mL) na profundidade de 10 centímetros foram coletadas em locais antes (local 1) e depois (local 2) da estação de tratamento de flotação, durante os meses da estação chuvosa e quente (janeiro, fevereiro e março) e da estação seca e fria (junho, julho e agosto) de 2008. Além disso, a temperatura, oxigênio dissolvido, condutividade e pH da água foram medidos com um equipamento Horiba U10. Coliformes totais e fecais foram analisados com o kit Aquatest®. A partir de cada amostra de água, alíquotas de 1 mL foram inoculadas em meio batata-dextrose-ágar, totalizando 10 placas de Petri para cada local de coleta. Após incubação por 10 dias a 22 ºC, as colônias fúngicas foram quantificadas, purificadas e identificadas. Os parâmetros abióticos da água não foram limitantes para a presença de geofungos, sendo influenciados pelo tratamento de flotação. Nos dois locais o número de coliformes totais e fecais foi predominantemente superior a 8 NMP dL-1 durante o período estudado. Vinte e sete táxons de fungos foram obtidos, distribuídos em 136 ocorrências. de acordo com o índice de similaridade de Sörensen, a micota dos dois locais coletados foram consideravelmente diferentes, apesar da semelhança entre o número de táxons e ocorrências. Os resultados indicam que o tratamento da água do Córrego do Sapateiro pelo sistema de flotação possivelmente causa modificações na composição taxonômica e na quantidade de UFC de fungos, ao contrário do que ocorreu com os coliformes totais e fecais, cujos resultados apresentaram-se menos conclusivos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. on predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alterações na densidade do substrato durante o cultivo das plantas modificam suas propriedades físicas. O trabalho teve como objetivos caracterizar fisicamente dois substratos hortícolas e avaliar o efeito da densidade na relação ar/água dos mesmos, elaborando funções matemáticas que permitam estimar tal relação a partir da densidade do substrato. Para tanto, determinou-se a distribuição do tamanho das partículas, a densidade e a curva de retenção de água. Procedeu-se o acondicionamento dos substratos em três valores de densidade: 10 (D1), 20 (D2) e 30% (D3) maior que a densidade (D) determinada na fase de caracterização. Partindo das amostras com diferentes densidades, determinou-se a curva de retenção de água dos substratos. A influência do aumento da densidade do substrato na porosidade total (PT), no espaço de aeração (EA), na água disponível (AD), na água facilmente disponível (AFD), na água tamponante (AT) e na água remanescente (AR) foi avaliada pela análise de regressão linear simples e análise polinomial. A composição granulométrica e a curva de retenção de água foram significativamente diferentes para os dois substratos. O aumento da densidade diminuiu a PT e o EA e aumentou a AT e AR. Os maiores valores de AD e AFD foram observados para D1. Foram obtidas equações de regressão que podem auxiliar na escolha da relação ar/água mais adequada para cada condição.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cultura da batata possui grande expressão econômica dentro do cenário agrícola. Para isso, equipamentos e técnicas de aplicação de produtos fitossanitários vêm sendo desenvolvidos visando melhorar o rendimento econômico da cultura. Neste sentido, experimentos foram conduzidos no delineamento em blocos ao acaso na cultura da batata cv. Ágata. Objetivando avaliar o efeito da assistência de ar combinada a diferentes ângulos de aplicação sobre a deposição da pulverização, bem como as perdas da calda para o solo utilizou-se um pulverizador com e sem assistência de ar junto à barra de pulverização posicionada a +30º, 0º e -30º (sinal + a favor e - contrário ao deslocamento) em relação a vertical. O volume de calda foi 400 L ha-1 utilizando-se pontas de jato cônico vazio JA-4 na pressão de 633 kPa. Para a avaliação dos depósitos utilizou-se um traçador cúprico. Os depósitos foram removidos dos folíolos por lavagem com água destilada, em ambas as superfícies foliares, nas posições superior e inferior das plantas de batata e quantificados por espectrofotometria de absorção atômica. As perdas da pulverização foram avaliadas em coletores plásticos colocados nas entrelinhas das parcelas experimentais. Os níveis dos depósitos do traçador cúprico nas diferentes posições da planta foram analisados pelo teste estatístico T² de Hotteling. Os maiores depósitos foram obtidos com a barra posicionada a 0º e +30º, em presença da assistência de ar, tanto na posição superior quanto inferior da planta. A presença do ar, além de propiciar maiores depósitos na parte inferior das plantas, possibilitou maior uniformidade na distribuição deles. As perdas da pulverização ficaram abaixo de 4%.