948 resultados para Dental polymers
Resumo:
This article reports clinical procedures used to remove residual bonded resin and enamel stains following bracket debonding at the conclusion of orthodontic treatment. A water-cooled fine-tapered diamond bur was used for resin removal, followed by enamel surface finishing using a commercially available microabrasion paste. It was noted that residual tooth coloration remained yellowish because of enamel translucency; the yellow dentin shade showed through. Additional tooth shade lightening was achieved using carbamide peroxide dental bleaching solution in custom-formed trays. This report describes a safe and effective technique that optimizes tooth appearance at the conclusion of orthodontic therapy. Mechanical resin removal, enamel microabrasion, and tooth bleaching are employed.
Resumo:
This study determined the presence of mutans streptococci and Candida spp. in supragingival. dental plaque and infected dentine of caries-free children, with early childhood caries and caries. Pooled samples of dental plaque and infected dentine were collected from 56 children aged 1-5 years, which were divided into 3 groups: early childhood caries (ECC); caries and caries-free. Infected dentine was collected in ECC and caries groups to compare the frequency of these microorganisms in the collected sites. The samples were inoculated in SB20 and SA medium, for mutans streptococci and Candida spp., respectively, and incubated at 37 degrees C for 48 h. Colony growth was verified and the identification was performed by biochemical tests and CHROMagar Candida. Fisher's test or chi-square (chi(2)) were applied (p = 0.05). The more prevalent species were S. mutans and Candida albicans in ECC (85.4% and 60.4%, respectively), independently of the sample site. S. mutans only was significantly associated with carious teeth, whether in early childhood caries or not. However, the frequency of C. albicans in ECC was higher when compared to caries and caries-free groups. There is a significant association between the presence of C. albicans and early childhood caries. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
OBJETIVO: comparar medidas de tamanhos dentários, suas reprodutibilidades e a aplicação da equação de regressão de Tanaka e Johnston na predição do tamanho dos caninos e pré-molares em modelos de gesso e digital. MÉTODOS: trinta modelos de gesso foram escaneados para obtenção dos modelos digitais. As medidas do comprimento mesiodistal dos dentes foram obtidas com paquímetro digital nos modelos de gesso e nos modelos digitais utilizando o software O3d (Widialabs). A somatória do tamanho dos incisivos inferiores foi utilizada para obter os valores de predição do tamanho dos pré-molares e caninos utilizando equação de regressão, e esses valores foram comparados ao tamanho real dos dentes. Os dados foram analisados estatisticamente, aplicando-se aos resultados o teste de correlação de Pearson, a fórmula de Dahlberg, o teste t pareado e a análise de variância (p < 0,05). RESULTADOS: excelente concordância intraexaminador foi observada nas medidas realizadas em ambos os modelos. O erro aleatório não esteve presente nas medidas obtidas com paquímetro, e o erro sistemático foi mais frequente no modelo digital. A previsão de espaço obtida pela aplicação da equação de regressão foi maior que a somatória dos pré-molares e caninos presentes nos modelos de gesso e nos modelos digitais. CONCLUSÃO: apesar da boa reprodutibilidade das medidas realizadas em ambos os modelos, a maioria das medidas dos modelos digitais foram superiores às do modelos de gesso. O espaço previsto foi superestimado em ambos os modelos e significativamente maior nos modelos digitais.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this study was to differentiate the dentoalveolar and skeletal effects to better understand orthodontic treatment. We evaluated the treatment changes associated with the bionator and the removable headgear splint (RHS). Methods: The sample comprised 51 consecutively treated Class II patients from 1 office who had all been successfully treated with either a bionator (n = 17) or an RHS appliance (n = 17). Class II patients waiting to start treatment later served as controls (n = 17). A modified version of the Johnston pitchfork analysis was used to quantify the dentoalveolar and skeletal contributions to the anteroposterior correction at the levels of the molars and the incisors. Results: Both appliances significantly improved anteroposterior molar relationships (2.15 mm for the bionator, 2.27 mm for the RHS), primarily by dentoalveolar modifications (1.49 and 2.36 mm for the bionator and the RHS, respectively), with greater maxillary molar distalization in the RHS group. Overjet relationships also improved significantly compared with the controls (3.11 and 2.12 mm for the bionator and the RHS, respectively), due primarily to retroclination of the maxillary incisors (2.2 and 2.38 mm for the bionator and the RHS, respectively). The differences between overall corrections and dentoalveolar modifications for both molar and overjet relationships were explained by skeletal responses, with the bionator group showing significantly greater anterior mandibular displacement than the RHS group. Conclusions: The bionator and the RHS effectively corrected the molar relationships and overjets of Class II patients primarily by dentoalveolar changes. (Am J Orthod Dentofacial Orthop 2008; 134: 732-41)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: To survey the current radiographic prescriptions in dental implant assessment amongst dentists in Brazil.Methods: Sixty-nine dentists were interviewed during a dental implant meeting by two calibrated graduate students, using a 19-question questionnaire, considering imaging modality options both for pre-operative implant site assessment and for follow-up, particularly with respect to cost, patient radiation dose, and broad coverage of facial bones and teeth. Epi-Info 6.04 software was used to analyse the database file.Results: Approximately 63.8% of the dentists prescribed only panoramic radiography for dental implant assessment and 28.9% ordered panoramic radiography plus periapical radiography and/or conventional tomography and/or computed tomography (CT). Only 7.2% of the dentists ordered conventional tomography or CT as a single examination, although 10.1% ordered it in combination with other imaging modalities. The main reasons given for prescribing panoramic radiography were broad coverage and cost (86.4%).Conclusions: This study has shown that most of the dentists in this study prescribe panoramic radiographs in dental implant assessment based on broad coverage and cost. They are not following the American Academy of Oral and Maxillofacial Radiology recommendations regarding cross-sectional imaging.
Resumo:
Background: the failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure.Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 +/- 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant.Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium.Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants.
Resumo:
To evaluate the influence of cyclosporin A (CsA) administration on bone around integrated dental implants assessed by a bone quality index and by quantitative subtraction radiography.A total of 36 machine surface commercial implants were placed in 18 adult rabbits. After a 3-month healing period without any disturbance, the animals were randomly divided into three groups of six animals each. Group A was sacrificed at this time. CsA was injected subcutaneously in an immunosuppressive dose of 10 mg/kg/day in a test group (Group T), and a Group B served as a control, receiving only vehicle. After 3 months of cyclosporin administration, the animals of both Groups B and T were sacrificed. Radiographs were obtained at implant surgery and at the day of sacrifice with a CMOS sensor. Bone quality around the implants was compared between the groups using a bone quality index and quantitative subtraction radiography.The bone analysis showed that in Group T, the bone quality changed dramatically from a dense cortical to a loose trabecular bone structure (P < 0.0001, chi(2) test) while in Groups A and B there were no significant differences. Quantitative digital subtraction radiography showed significantly (P < 0.05) lower gray shade values (radiographic density) in a region of bone formation around the implants in Group T (118 +/- 12) than in Groups A (161 +/- 6) and B (186 +/- 10).Within the limits of this study, CsA administration has a negative effect on the quality of bone around integrated dental implant.
Resumo:
Background: The aim of the present study was to evaluate clinical and radiographic changes that occur around dental implants inserted in different levels in relation to crestal bone under different restoration protocols.Methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1 mm below crestal bone), or Minus 2 (2 mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prosthesis was installed 120 days after implant placement, including 30 days with healing cap) or immediate (prosthesis was installed 24 hours after implant placement). Fixed partial prostheses were installed bilaterally in the same day. After 90 days, clinical and radiographic parameters were evaluated.Results: As long as the implants were inserted in more apical positions, the first bone-to-implant contact (fBIC) was positioned more apically (P<0.05). However, the apical positioning of the implants did not influence the ridge loss or the position of the soft tissue margin (PSTM) (P>0.05). In addition, in immediately restored sites, the PSTM was located significantly more coronally than that in conventionally restored sites (P=0.02).Conclusions: Despite the more apical positioning of the fBIC, the height of the peri-implant soft tissues and ridge was not jeopardized. Moreover, the immediate restoration protocol was beneficial to the maintenance of the PSTM. Further studies are suggested to evaluate the significance of these results in longer healing periods.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)