914 resultados para Dean Adami


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Perspex Machine arose from the unification of computation with geometry. We now report significant redevelopment of both a partial C compiler that generates perspex programs and of a Graphical User Interface (GUI). The compiler is constructed with standard compiler-generator tools and produces both an explicit parse tree for C and an Abstract Syntax Tree (AST) that is better suited to code generation. The GUI uses a hash table and a simpler software architecture to achieve an order of magnitude speed up in processing and, consequently, an order of magnitude increase in the number of perspexes that can be manipulated in real time (now 6,000). Two perspex-machine simulators are provided, one using trans-floating-point arithmetic and the other using transrational arithmetic. All of the software described here is available on the world wide web. The compiler generates code in the neural model of the perspex. At each branch point it uses a jumper to return control to the main fibre. This has the effect of pruning out an exponentially increasing number of branching fibres, thereby greatly increasing the efficiency of perspex programs as measured by the number of neurons required to implement an algorithm. The jumpers are placed at unit distance from the main fibre and form a geometrical structure analogous to a myelin sheath in a biological neuron. Both the perspex jumper-sheath and the biological myelin-sheath share the computational function of preventing cross-over of signals to neurons that lie close to an axon. This is an example of convergence driven by similar geometrical and computational constraints in perspex and biological neurons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A robot mounted camera is useful in many machine vision tasks as it allows control over view direction and position. In this paper we report a technique for calibrating both the robot and the camera using only a single corresponding point. All existing head-eye calibration systems we have encountered rely on using pre-calibrated robots, pre- calibrated cameras, special calibration objects or combinations of these. Our method avoids using large scale non-linear optimizations by recovering the parameters in small dependent groups. This is done by performing a series of planned, but initially uncalibrated robot movements. Many of the kinematic parameters are obtained using only camera views in which the calibration feature is at, or near the image center, thus avoiding errors which could be introduced by lens distortion. The calibration is shown to be both stable and accurate. The robotic system we use consists of camera with pan-tilt capability mounted on a Cartesian robot, providing a total of 5 degrees of freedom.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Along-Track Scanning Radiometers (ATSRs) provide a long time-series of measurements suitable for the retrieval of cloud properties. This work evaluates the freely-available Global Retrieval of ATSR Cloud Parameters and Evaluation (GRAPE) dataset (version 3) created from the ATSR-2 (1995�2003) and Advanced ATSR (AATSR; 2002 onwards) records. Users are recommended to consider only retrievals flagged as high-quality, where there is a good consistency between the measurements and the retrieved state (corresponding to about 60% of converged retrievals over sea, and more than 80% over land). Cloud properties are found to be generally free of any significant spurious trends relating to satellite zenith angle. Estimates of the random error on retrieved cloud properties are suggested to be generally appropriate for optically-thick clouds, and up to a factor of two too small for optically-thin cases. The correspondence between ATSR-2 and AATSR cloud properties is high, but a relative calibration difference between the sensors of order 5�10% at 660 nm and 870 nm limits the potential of the current version of the dataset for trend analysis. As ATSR-2 is thought to have the better absolute calibration, the discussion focusses on this portion of the record. Cloud-top heights from GRAPE compare well to ground-based data at four sites, particularly for shallow clouds. Clouds forming in boundary-layer inversions are typically around 1 km too high in GRAPE due to poorly-resolved inversions in the modelled temperature profiles used. Global cloud fields are compared to satellite products derived from the Moderate Resolution Imaging Spectroradiometer (MODIS), Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) measurements, and a climatology of liquid water content derived from satellite microwave radiometers. In all cases the main reasons for differences are linked to differing sensitivity to, and treatment of, multi-layer cloud systems. The correlation coefficient between GRAPE and the two MODIS products considered is generally high (greater than 0.7 for most cloud properties), except for liquid and ice cloud effective radius, which also show biases between the datasets. For liquid clouds, part of the difference is linked to choice of wavelengths used in the retrieval. Total cloud cover is slightly lower in GRAPE (0.64) than the CALIOP dataset (0.66). GRAPE underestimates liquid cloud water path relative to microwave radiometers by up to 100 g m�2 near the Equator and overestimates by around 50 g m�2 in the storm tracks. Finally, potential future improvements to the algorithm are outlined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aerosol component of the Oxford-Rutherford Aerosol and Cloud (ORAC) combined cloud and aerosol retrieval scheme is described and the theoretical performance of the algorithm is analysed. ORAC is an optimal estimation retrieval scheme for deriving cloud and aerosol properties from measurements made by imaging satellite radiometers and, when applied to cloud free radiances, provides estimates of aerosol optical depth at a wavelength of 550 nm, aerosol effective radius and surface reflectance at 550 nm. The aerosol retrieval component of ORAC has several incarnations – this paper addresses the version which operates in conjunction with the cloud retrieval component of ORAC (described by Watts et al., 1998), as applied in producing the Global Retrieval of ATSR Cloud Parameters and Evaluation (GRAPE) data-set.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Global Retrieval of ATSR Cloud Parameters and Evaluation (GRAPE) project has produced a global data-set of cloud and aerosol properties from the Along Track Scanning Radiometer-2 (ATSR-2) instrument, covering the time period 1995�2001. This paper presents the validation of aerosol optical depths (AODs) over the ocean from this product against AERONET sun-photometer measurements, as well as a comparison to the Advanced Very High Resolution Radiometer (AVHRR) optical depth product produced by the Global Aerosol Climatology Project (GACP). The GRAPE AOD over ocean is found to be in good agreement with AERONET measurements, with a Pearson's correlation coefficient of 0.79 and a best-fit slope of 1.0±0.1, but with a positive bias of 0.08±0.04. Although the GRAPE and GACP datasets show reasonable agreement, there are significant differences. These discrepancies are explored, and suggest that the downward trend in AOD reported by GACP may arise from changes in sampling due to the orbital drift of the AVHRR instruments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cleft lip and palate is the most common of the congenital conditions affecting the face and cranial bones and is associated with a raised risk of difficulties in infant-caregiver interaction; the reasons for such difficulties are not fully understood. Here, we report two experiments designed to explore how adults respond to infant faces with and without cleft lip, using behavioural measures of attractiveness appraisal (‘liking’) and willingness to work to view or remove the images (‘wanting’). We found that infants with cleft lip were rated as less attractive and were viewed for shorter durations than healthy infants, an effect that was particularly apparent where the cleft lip was severe. Women rated the infant faces as more attractive than men did, but there were no differences in men and women's viewing times of these faces. In a second experiment, we found that the presence of a cleft lip in domestic animals affected adults' ‘liking’ and ‘wanting’ responses in a comparable way to that seen for human infants. Adults' responses were also remarkably similar for images of infants and animals with cleft lip, although no gender difference in attractiveness ratings or viewing times emerged for animals. We suggest that the presence of a cleft lip can substantially change the way in which adults respond to human and animal faces. Furthermore, women may respond in different ways to men when asked to appraise infant attractiveness, despite the fact that men and women ‘want’ to view images of infants for similar durations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine the prevalence and nature of prescribing errors in general practice; to explore the causes, and to identify defences against error. Methods: 1) Systematic reviews; 2) Retrospective review of unique medication items prescribed over a 12 month period to a 2% sample of patients from 15 general practices in England; 3) Interviews with 34 prescribers regarding 70 potential errors; 15 root cause analyses, and six focus groups involving 46 primary health care team members Results: The study involved examination of 6,048 unique prescription items for 1,777 patients. Prescribing or monitoring errors were detected for one in eight patients, involving around one in 20 of all prescription items. The vast majority of the errors were of mild to moderate severity, with one in 550 items being associated with a severe error. The following factors were associated with increased risk of prescribing or monitoring errors: male gender, age less than 15 years or greater than 64 years, number of unique medication items prescribed, and being prescribed preparations in the following therapeutic areas: cardiovascular, infections, malignant disease and immunosuppression, musculoskeletal, eye, ENT and skin. Prescribing or monitoring errors were not associated with the grade of GP or whether prescriptions were issued as acute or repeat items. A wide range of underlying causes of error were identified relating to the prescriber, patient, the team, the working environment, the task, the computer system and the primary/secondary care interface. Many defences against error were also identified, including strategies employed by individual prescribers and primary care teams, and making best use of health information technology. Conclusion: Prescribing errors in general practices are common, although severe errors are unusual. Many factors increase the risk of error. Strategies for reducing the prevalence of error should focus on GP training, continuing professional development for GPs, clinical governance, effective use of clinical computer systems, and improving safety systems within general practices and at the interface with secondary care.