913 resultados para Continuation vs rupture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significantly more individuals and biomass of flying insects were present at the forest edge than in the understory throughout the year, as monitored by flight interception traps, in Central Amazonia. Numbers and biomass of flying insects increased at higher rates at the edge with rainfall, associated with termite swarming behavior and increased Homopteran density. The most abundant insects were Diptera, Coleoptera, Hymenoptera and Isoptera, whose ranked abundances varied with respect to forest edge and understory, as well as with season.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and inexpensive way to fabricate arrays of gold microelectrodes is proposed. Integrated circuit chips are sawed through their middle, normal to the longest axis, leading to destruction of the silicon circuit and rupture of the gold wires that interconnect it with the external terminals. Polishing the resulting rough surface converts the tips of the wires embedded in the chip halves into arrays of gold microdisks of about 25 mu m diameter. The number of active microelectrodes (MEs), of an array depends on the number of pins in the chip, n, being typically (n/2)-4. These MEs can be used individually or externally interconnected in any combination. X-ray images of the chips and micrographs of the resulting surface of the polished arrays have revealed variable distances between neighbor MEs, which are, however, larger than 10 times the radius of the disks. This feature of the MEs prevents diffusional cross-talk between electrodes. The use of these microdisk electrodes for analytical purposes exhibits sigmoidal voltammograms, and chronoamperometric experiments confirm the nonlinear i vs. t(1/2) plots, typical for processes where radial diffusion prevails. Satisfactory uniformity was observed for the response of each electrode of an array, indicating similarity of geometry and disk areas. The potentialities of these MEs were demonstrated by the determination of cadmium at ppb levels using square wave voltammetry with preconcentration. Due to the relative ease with which these MEs can be manufactured and their good performance in (chemical) analysis, wide applications in electrochemistry and electroanalysis is envisioned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the proposal was to study the presence of immunoglobulin A (IgA) in the chorioamniotic membrane of healthy postpartum women with premature rupture of the chorioamniotic membrane (FROM). Method: A single radial immunodiffusion technique was used to quantify the IgA in the chorioamniotic membrane tissues. Results: the level of IgA was approximately 10 times higher in patients whose membranes had been ruptured for > 10 h (24.58 mg/dl). These results were compared with those of a previously published study where the mean of amount of IgA was 2.52 mg/dl in membranes of patients with rupture < 10 h. Our results show that IgA began to rise after 10-15 h following rupture. Conclusion: Although more studies need to be performed our data indicate that the increasing IgA in our patients after 10 h of latency probably represents the beginning of an ascending colonization of bacteria which could be the source of future infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional Newton's method is considered to be inadequate for the computation of the maximum loading point (MLP) of power systems since: (i) it encounters difficulties in the vicinity of the MLP: and (ii) the load flow Jacobian matrix becomes singular at the MLP. It is well known that continuation methods are powerful and useful tools that are able to trace the solution PV curve without experiencing such diffculties. However, continuation methods require a parameterisation so that a modified, well conditioned set of load flow equations is obtained. In particular, the Jacobian matrix associated with this modified set of equations should not be singular at the MLP. The authors propose that the actual power losses in transmission branches (lines and transformers) are used to parameterise the approach. Specific procedures for the automatic determination of the most appropriate parameter (branch) are proposed. Such procedures include the utilisation of fast voltage-stability indices. Simulation results are presented to show that the proposed method is able to trace the whole solution PV curve very efficiently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional power flow method is considered to be inadequate to obtain the maximum loading point because of the singularity of Jacobian matrix. Continuation methods are efficient tools for solving this kind of problem since different parameterization schemes can be used to avoid such ill-conditioning problems. This paper presents the details of new schemes for the parameterization step of the continuation power flow method. The new parameterization options are based on physical parameters, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and transmission line power losses (real and reactive). The simulation results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are not only preserved but also improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New parameterization schemes have been proposed by the authors in Part I of this paper. In this part these new options for the parameterization of power flow equations are tested, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and the transmission line power losses (real and reactive). These different parameterization schemes can be used to obtain the maximum loading point without ill-conditioning problems, once the singularity of Jacobian matrix is avoided. The results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) show that the characteristics of the conventional method are not only preserved but also improved. In addition, it is shown that the proposed method and the conventional one can be switched during the tracing of PV curves to determine, with few iterations, all points of the PV curve. Several tests were also carried out to compare the performance of the proposed parameterization schemes for the continuation power flow method with the use of both the secant and tangent predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adult Swiss (susceptible) and BALB/c (non-susceptible) mice were inoculated by the intravenous route with 1 x 10(6) yeast cells of Paracoccidioides brasiliensis, strain 18. Immunologic parameters, histopathology and features of the bronchoalveolar lavage (BAL) were evaluated at week 2, 4, 8 and 16 post-infection. The pulmonary infection was progressive in Swiss mice and regressive in BALB/c mice. The numbers of total cells, lymphocytes and polymorphonuclear neutrophils increased in BAL, as well as the percentages of giant cells, and CD4 and CD8 positive cells. The ultrastructural study of BAL cells revealed a predominance of macrophages and a frequency of 13.2% of type II pneumocytes. As the infection progressed, the number of fungal cells and spreading macrophages, as well as the stimulated release of H2O2 by macrophages, increased. The animals exhibited an exacerbation of the humoral immune response and a depression of cellular immunity during the infection. There was a good correlation between the intensity and the pattern of the pulmonary histopathology and the cellular findings in the BAL. The present model reproduces some anatomoclinical patterns of the human disease and shows that BAL may be a useful tool in monitoring the pulmonary infection caused by P. brasiliensis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuation methods have been shown as efficient tools for solving ill-conditioned cases, with close to singular Jacobian matrices, such as the maximum loading point of power systems. Some parameterization techniques have been proposed to avoid matrix singularity and successfully solve those cases. This paper presents a new geometric parameterization scheme that allows the complete tracing of the P-V curves without ill-conditioning problems. The proposed technique associates robustness to simplicity and, it is of easy understanding. The Jacobian matrix singularity is avoided by the addition of a line equation, which passes through a point in the plane determined by the total real power losses and loading factor. These two parameters have clear physical meaning. The application of this new technique to the IEEE systems (14, 30, 57, 118 and 300 buses) shows that the best characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2006 Elsevier B.V. All rights reserved.