934 resultados para Confocal laser scanning microscopy (CLSM)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The external morphology of eggs of the species Belminus corredori Galvao & Angulo, 2006, Belminus herreri Lent & Wygodzinsky, 1979 and Belminus ferroae Sandoval, Pabon, Jurberg & Galvao, 2007 is described for the first time using scanning electron microscopy (SEM). Females lay one egg at a time; the shape of the egg is oval with lateral flattening, a rounded caudal area and a true and simple convex operculum. The average size of the egg among these species is 0.51-0.58 mm in length and 0.36-0.4 mm in width. As a generic character we highlight the discovery of a chorion rim with one to four grooves always joined to the micropyles. All species present a clear polygonal pattern only in the operculum and in the egg's cephalic region, while the median and caudal regions show a smooth appearance, features that are shared only with the eggs of the genus Alberprosenia. A discriminant analysis of the polygonal design of the operculum proved to be useful for the identification of the species.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The stretch zone width (SZW) data for 15-5PH steel CTOD specimens fractured at -150 degrees C to + 23 degrees C temperature were measured based on focused images and 3D maps obtained by extended depth-of-field reconstruction from light microscopy (LM) image stacks. This LM-based method, with a larger lateral resolution, seems to be as effective for quantitative analysis of SZW as scanning electron microscopy (SEM) or confocal scanning laser microscopy (CSLM), permitting to clearly identify stretch zone boundaries. Despite the worst sharpness of focused images, a robust linear correlation was established to fracture toughness (KC) and SZW data for the 15-5PH steel tested specimens, measured at their center region. The method is an alternative to evaluate the boundaries of stretched zones, at a lower cost of implementation and training, since topographic data from elevation maps can be associated with reconstructed image, which summarizes the original contrast and brightness information. Finally, the extended depth-of-field method is presented here as a valuable tool for failure analysis, as a cheaper alternative to investigate rough surfaces or fracture, compared to scanning electron or confocal light microscopes. Microsc. Res. Tech. 75:11551158, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P. zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the important factors accounting for successful delayed replantation of avulsed teeth is seemingly the type of root surface treatment. Removal of necrotic cemental periodontal ligament remnants may prevent the occurrence of external root resorption, which is the major cause of loss of teeth replanted in such conditions. The purpose of this study was to compare the efficacy of two mechanical techniques for removal of root-adhered periodontal ligament. Preservation or removal of the cementum layer concomitantly with these procedures was also assessed. Forty-five roots of healthy premolars extracted for orthodontic purposes were selected. After extraction, the teeth were kept dry at room temperature for 1 h and then immersed in saline for rehydration for an additional 10 min. Thereafter, the roots were assigned to three groups, as follows: group 1 (control) - the cemental periodontal ligament was preserved; group 2 - removal of the periodontal ligament by scraping root surface with a scalpel blade (SBS); group 3 - periodontal ligament remnants were removed using a Robinson bristle brush at low-speed with pumice/water slurry (RBP). The specimens were analysed histomorphometrically and examined by scanning electron microscopy. The quantitative and qualitative analyses of the results showed that the RBP technique was significantly more effective than the SBS technique for removal of the periodontal ligament remnants adhered to root surface. Both techniques preserved the cementum layer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJETIVO: Estudar a superfície de implantes osseointegráveis utilizando discos de titânio irradiados com feixe de laser. MÉTODOS: A amostra foi irradiada com feixes de laser de alta intensidade (Nd-YAG), posteriormente depositado hidróxiapatita e submetido a tratamento térmico. Foi analisada sob MEV (Microscópio Eletrônico de Varredura) e realizada análise morfológica qualitativa com microfotografias em vários aumentos. RESULTADOS: A superfície irradiada com laser apresentou deformidade superficial e característica isomórfica; a aplicação de hidroxiapatita pelo método de biomimético aumentou quantitativamente a área da superfície de titânio. CONCLUSÃO: A deposição de hidroxiapatita apresentou melhor característica isomórfica e aumento quantitativo da área superficial estudada, a amostra demonstrou características não encontradas nos implantes disposto no mercado.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: the aim of the present study was to compare the effects of Er:YAG and diode laser treatments of the root surface on intrapulpal temperature after scaling and root planing with hand instruments.Methods: Fifteen extracted single-rooted teeth were scaled and root planed with hand instruments. The teeth were divided into 3 groups of 5 each and irradiated on their buccal and lingual surfaces: group A: Er:YAG laser, 2.94 mum/100 mJ/10 Hz/ 30 seconds; group B: diode laser, 810 nm/1.0 W/0.05 ms/30 seconds; group C: diode laser, 810 nm/1.4 W/0.05 ms/30 seconds. The temperature was monitored by means of a type T thermocouple (copper-constantan) positioned in the pulp chamber to assess pulpal temperature during and before irradiation. Afterwards, the specimens were longitudinally sectioned, and the buccal and lingual surfaces of each root were analyzed by scanning electron microscopy.Results: In the Er:YAG laser group, the thermal analysis revealed an average temperature of -2.2 +/- 1.5degreesC, while in the diode laser groups, temperatures were 1.6 +/- 0.8degreesC at 1.0 W and 3.3 +/- 1.0degreesC at 1.4 W. Electronic micrographs revealed that there were no significant morphological changes, such as charring, melting, or fusion, in any group, although the specimens were found to be more irregular in the Er:YAG laser group.Conclusions: the application of Er:YAG and diode lasers at the utilized parameters did not induce high pulpal temperatures. Root surface irregularities were more pronounced after irradiation with an Er:YAG laser than with a diode laser.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: the failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure.Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 +/- 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant.Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium.Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants.