976 resultados para Concreto - Tecnologia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Informação - FFC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper discusses the application of High Strength Concrete (HSC) technology for concrete production with the incorporation of Rice Husk Ash (RHA) residues by replacing a bulk of the material caking and rubber tires with partial aggregate volume, assessing their influence on the mechanical properties and durability. For concrete with RHA and rubber, it was possible to reduce the brittleness by increasing the energy absorbing capacity. With respect to abrasion, the RHA and rubber concretes showed lower mass loss than the concrete without residues, indicating that this material is attractive to be used in paving. It is thus hoped that these residues may represent a technological and ecological alternative for the production of concrete in construction works.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigated the influence of the amount of superplasticizer and mineral adding - silica fume and basaltic filer - in plastic shrinkage and cracking of self-compacting concrete (SCC) mortars. Initially analysis was performed of the rheological behavior of cement paste and mortars phases of the compositions of SCC. Then the deformations of mortars were measured by the effect of shrinkage and evaluation of cracking. On plastic shrinkage and cracking, the composition with silica fume showed superior results, independent of wind and superplasticizer content, relative to the composition with addition of basalt filler. However, the composition with silica fume showed superior results only in the tests with imposed ventilation at vertical plastic deformation. The rheological behavior affected directly the plastic shrinkage and cracking at early ages, fact confirmed by the analysis of capillary pressures of mortars tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The bond between steel and concrete is essential for the existence of reinforced concrete structures, as both materials act together to absorb structural strain. The bond phenomenon is considered to be complex regarding many factors that affect it. Several types of bond tests have been proposed over years. One is the modified proposed of pull-out test, which was elaborated by Lorrain and Barbosa [1] called APULOT test (Appropriete pull-out-test). Based on experimental results obtained by Vale Silva[2] either by conventional pull-out tests, or by modified pull-out test, APULOT, seeks to know the numeric behavior of bond steel-concrete through a numerical simulation using a calculation code ATENA which is based on the Finite Element Method (FEM). The numerical simulation provided better evaluate the stress distribution and cracking that occurs during the test, thereby becoming a valuable tool to support the experimental project that aims to validation, validation partially or not recommend the modified bond test steel-concrete - APULOT test - as quality control test of structural concrete. The numerical results showed good representation compared to experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the following aspects regarding a soakaway, i.e. an infiltration well: i) entrance filter device; ii) permeability of the geotextile; and iii) emptying time. The 3.6 m³ infiltration well drains a roof area of 241.8 m². The entrance device is made up of layers of sand, gravel and geotextile set on a metal structure. The concrete rings that form the lateral walls were covered with geotextile, and bricks were laid between the soil and concrete rings. The infiltration well remained in operation during the entire testing period, and specific events were simulated to measure the emptying time. Permeability and fine particle tests were carried out after eight months of operation. Samples of geotextile taken from the bottom, the walls and the entrance device presented average permeability reductions of approximately 50.7%, 7.7% and 21.2%, respectively. The sand in the entrance device retained around 34.8% of fine particles and the gravel retained 0.13% in the same period. The infiltration rate was approximately 34.7 mm/h. The R2 coefficient for measured and calculated times was 0.97.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)