945 resultados para Computerized Axial Tomography
Resumo:
The purpose of this study was to compare inter-observer agreement of Stratus™ OCT versus Spectralis™ OCT image grading in patients with neovascular age-related macular degeneration (AMD). Thirty eyes with neovascular AMD were examined with Stratus™ OCT and Spectralis™ OCT. Four different scan protocols were used for imaging. Three observers graded the images for the presence of various pathologies. Inter-observer agreement between OCT models was assessed by calculating intra-class correlation coefficients (ICC). In Stratus™ OCT highest interobserver agreement was found for subretinal fluid (ICC: 0.79), and in Spectralis™ OCT for intraretinal cysts (IRC) (ICC: 0.93). Spectralis™ OCT showed superior interobserver agreement for IRC and epiretinal membranes (ERM) (ICC(Stratus™): for IRC 0.61; for ERM 0.56; ICC(Spectralis™): for IRC 0.93; for ERM 0.84). Increased image resolution of Spectralis™ OCT did improve the inter-observer agreement for grading intraretinal cysts and epiretinal membranes but not for other retinal changes.
Resumo:
Detailed knowledge of cervical canal and transverse foramens' morphometry is critical for understanding the pathology of certain diseases and for proper preoperative planning. Lateral x-rays do not provide the necessary accuracy. A retrospective morphometric study of the cervical canal was performed at the authors' institution to measure mean dimensions of sagittal canal diameter (SCD), right and left transverse foramens' sagittal (SFD) and transverse (TFD) diameters and minimum distance between spinal canal and transverse foramens (dSC-TF) for each level of the cervical spine from C1-C7, using computerized tomographic scans, in 100 patients from the archives of the Emergency Room.
Resumo:
To demonstrate the potential benefits of biochemical axial T2 mapping of intervertebral discs (IVDs) regarding the detection and grading of early stages of degenerative disc disease using 1.5-Tesla magnetic resonance imaging (MRI) in a clinical setting.
Resumo:
This study sought to assess stent strut coverage, malapposition, protrusion, and coronary evaginations as markers of healing 5 years after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), by optical coherence tomography (OCT).
Resumo:
Arterio-venous malformations (AVMs) are congenital vascular malformations (CVMs) that result from birth defects involving the vessels of both arterial and venous origins, resulting in direct communications between the different size vessels or a meshwork of primitive reticular networks of dysplastic minute vessels which have failed to mature to become 'capillary' vessels termed "nidus". These lesions are defined by shunting of high velocity, low resistance flow from the arterial vasculature into the venous system in a variety of fistulous conditions. A systematic classification system developed by various groups of experts (Hamburg classification, ISSVA classification, Schobinger classification, angiographic classification of AVMs,) has resulted in a better understanding of the biology and natural history of these lesions and improved management of CVMs and AVMs. The Hamburg classification, based on the embryological differentiation between extratruncular and truncular type of lesions, allows the determination of the potential of progression and recurrence of these lesions. The majority of all AVMs are extra-truncular lesions with persistent proliferative potential, whereas truncular AVM lesions are exceedingly rare. Regardless of the type, AV shunting may ultimately result in significant anatomical, pathophysiological and hemodynamic consequences. Therefore, despite their relative rarity (10-20% of all CVMs), AVMs remain the most challenging and potentially limb or life-threatening form of vascular anomalies. The initial diagnosis and assessment may be facilitated by non- to minimally invasive investigations such as duplex ultrasound, magnetic resonance imaging (MRI), MR angiography (MRA), computerized tomography (CT) and CT angiography (CTA). Arteriography remains the diagnostic gold standard, and is required for planning subsequent treatment. A multidisciplinary team approach should be utilized to integrate surgical and non-surgical interventions for optimum care. Currently available treatments are associated with significant risk of complications and morbidity. However, an early aggressive approach to elimiate the nidus (if present) may be undertaken if the benefits exceed the risks. Trans-arterial coil embolization or ligation of feeding arteries where the nidus is left intact, are incorrect approaches and may result in proliferation of the lesion. Furthermore, such procedures would prevent future endovascular access to the lesions via the arterial route. Surgically inaccessible, infiltrating, extra-truncular AVMs can be treated with endovascular therapy as an independent modality. Among various embolo-sclerotherapy agents, ethanol sclerotherapy produces the best long term outcomes with minimum recurrence. However, this procedure requires extensive training and sufficient experience to minimize complications and associated morbidity. For the surgically accessible lesions, surgical resection may be the treatment of choice with a chance of optimal control. Preoperative sclerotherapy or embolization may supplement the subsequent surgical excision by reducing the morbidity (e.g. operative bleeding) and defining the lesion borders. Such a combined approach may provide an excellent potential for a curative result. Conclusion. AVMs are high flow congenital vascular malformations that may occur in any part of the body. The clinical presentation depends on the extent and size of the lesion and can range from an asymptomatic birthmark to congestive heart failure. Detailed investigations including duplex ultrasound, MRI/MRA and CT/CTA are required to develop an appropriate treatment plan. Appropriate management is best achieved via a multi-disciplinary approach and interventions should be undertaken by appropriately trained physicians.
Resumo:
Advances in diagnostic imaging and the introduction of damage control strategy in trauma have influenced our approach to treating liver trauma patients. The objective of the present study was to investigate the impact of change in liver trauma management on outcome.
Resumo:
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Resumo:
The vascular-stromal compartment of lymph nodes is important for lymph node function, and high endothelial venules (HEVs) play a critical role in controlling the entry of recirculating lymphocytes. In autoimmune and autoinflammatory diseases, lymph node swelling is often accompanied by apparent HEV expansion and, potentially, targeting HEV expansion could be used therapeutically to limit autoimmunity. In previous studies using mostly flow cytometry analysis, we defined three differentially regulated phases of lymph node vascular-stromal growth: initiation, expansion, and the re-establishment of vascular quiescence and stabilization. In this study, we use optical projection tomography to better understand the morphologic aspects of HEV growth upon immunization with ovalbumin/CFA (OVA/CFA). We find HEV elongation as well as modest arborization during the initiation phase, increased arborization during the expansion phase, and, finally, vessel narrowing during the re-establishment of vascular quiescence and stabilization. We also examine acutely enlarged autoinflammatory lymph nodes induced by regulatory T cell depletion and show that HEVs are expanded and morphologically similar to the expanded HEVs in OVA/CFA-stimulated lymph nodes. These results reinforce the idea of differentially regulated, distinct phases of vascular-stromal growth after immunization and suggest that insights gained from studying immunization-induced lymph node vascular growth may help to understand how the lymph node vascular-stromal compartment could be therapeutically targeted in autoimmune and autoinflammatory diseases.
Resumo:
Whole-body computed tomography (WBCT) plays an important role in the management of severely injured patients. We evaluated the radiation exposure of WBCT scans using different positioning boards and arm positions.
Resumo:
To demonstrate the feasibility and potential usefulness of an offline fusion of matched optical coherence tomography (OCT) and intravascular ultrasound (IVUS)/virtual histology (IVUS-VH) images.
Resumo:
The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease.
Resumo:
To quantify the circumferential healing process at 6 and 12 months following scaffold implantation.
Resumo:
To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.
Resumo:
To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.