942 resultados para Comprehensive two-dimensional gas chromatography–time of flight mass spectrometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bottom-up approach is introduced to fabricate two-dimensional self-assembled layers of molecular spin-systems containing Mn and Fe ions arranged in a chessboard lattice. We demonstrate that the Mn and Fe spin states can be reversibly operated by their selective response to coordination/decoordination of volatile ligands like ammonia (NH3).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was to determine the effect of body mass index (BMI) on response to bacterial vaginosis (BV) treatment. A secondary analysis was conducted of two multicenter trials of therapy for BV and TRICHOMONAS VAGINALIS. Gravida were screened for BV between 8 and 22 weeks and randomized between 16 and 23 weeks to metronidazole or placebo. Of 1497 gravida with asymptomatic BV and preconceptional BMI, 738 were randomized to metronidazole; BMI was divided into categories: < 25, 25 to 29.9, and > or = 30. Rates of BV persistence at follow-up were compared using the Mantel-Haenszel chi square. Multiple logistic regression was used to evaluate the effect of BMI on BV persistence at follow-up, adjusting for potential confounders. No association was identified between BMI and BV rate at follow-up ( P = 0.21). BMI was associated with maternal age, smoking, marital status, and black race. Compared with women with BMI of < 25, adjusted odds ratio (OR) of BV at follow-up were BMI 25 to 29.9: OR, 0.66, 95% CI 0.43 to 1.02; BMI > or = 30: OR, 0.83, 95% CI 0.54 to 1.26. We concluded that the persistence of BV after treatment was not related to BMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was to determine the effect of body mass index (BMI) on response to bacterial vaginosis (BV) treatment. A secondary analysis was conducted of two multicenter trials of therapy for BV and TRICHOMONAS VAGINALIS. Gravida were screened for BV between 8 and 22 weeks and randomized between 16 and 23 weeks to metronidazole or placebo. Of 1497 gravida with asymptomatic BV and preconceptional BMI, 738 were randomized to metronidazole; BMI was divided into categories: < 25, 25 to 29.9, and > or = 30. Rates of BV persistence at follow-up were compared using the Mantel-Haenszel chi square. Multiple logistic regression was used to evaluate the effect of BMI on BV persistence at follow-up, adjusting for potential confounders. No association was identified between BMI and BV rate at follow-up ( P = 0.21). BMI was associated with maternal age, smoking, marital status, and black race. Compared with women with BMI of < 25, adjusted odds ratio (OR) of BV at follow-up were BMI 25 to 29.9: OR, 0.66, 95% CI 0.43 to 1.02; BMI > or = 30: OR, 0.83, 95% CI 0.54 to 1.26. We concluded that the persistence of BV after treatment was not related to BMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A micro-electrospray interface was developed specifically for the neurobiological applications described in this dissertation. Incorporation of a unique nano-flow liquid chromatography micro-electrospray "needle" into the micro-electrospray interface (micro-ES/MS) increased the sensitivity of the mass spectrometric assay by $\sim$1000 fold and thus permitted the first analysis of specific neuroactive compounds in brain extracellular fluid collected by in vivo microdialysis (Md).^ Initial in vivo data presented deals with the pharmacodynamics of a novel GABA$\sb{\rm B}$ antagonist and the availability of the compound in its parent (unmetabolized) form to the brain of the anesthetized rat. Next, the first structurally specific endogenous release of (Met) $\sp5$-enkephalin was demonstrated in unanesthetized freely-moving animals (release of $\sim$6.5 fmole of (Met) $\sp5$-enkephalin into the dialysate by direct neuronal depolarization). The Md/micro-ES/MS system was used to test the acute effects of drugs of abuse on the endogenous release of (Met) $\sp5$-enkephalin from the globus pallidus/ventral pallidum brain region in rats. Four drugs known to be abused by man (morphine, cocaine, methamphetamine and diazepam) were tested. Morphine and cocaine both elicited a two-fold or more increase in the release of (Met) $\sp5$-enkephalin over vehicle controls. Diazepam elicited a small decrease in (Met) $\sp5$-enkephalin levels and methamphetamine showed no significant effect on (Met) $\sp5$-enkephalin. These results imply that (Met) $\sp5$-enkephalin may be involved in the reward pathway of certain drugs of abuse. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A quantum simulator of U(1) lattice gauge theories can be implemented with superconducting circuits. This allows the investigation of confined and deconfined phases in quantum link models, and of valence bond solid and spin liquid phases in quantum dimer models. Fractionalized confining strings and the real-time dynamics of quantum phase transitions are accessible as well. Here we show how state-of-the-art superconducting technology allows us to simulate these phenomena in relatively small circuit lattices. By exploiting the strong non-linear couplings between quantized excitations emerging when superconducting qubits are coupled, we show how to engineer gauge invariant Hamiltonians, including ring-exchange and four-body Ising interactions. We demonstrate that, despite decoherence and disorder effects, minimal circuit instances allow us to investigate properties such as the dynamics of electric flux strings, signaling confinement in gauge invariant field theories. The experimental realization of these models in larger superconducting circuits could address open questions beyond current computational capability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In continuation of the long tradition of mass spectrometric research at the University of Bern, our group focuses on the characterization of nucleic acids as therapeutic agents and as drug targets. This article provides a short overview of our recent work on platinated single-stranded and higher-order nucleic acids. Nearly three decades ago the development of soft ionization techniques opened a whole new chapter in the mass spectrometric analysis of not only nucleic acids themselves, but also their interactions with potential drug candidates. In contrast to modern next generation sequencing approaches, though, the goal of the tandem mass spectrometric investigation of nucleic acids is by no means the complete sequencing of genetic DNA, but rather the characterization of short therapeutic and regulatory oligonucleotides and the elucidation of nucleic acid–drug interactions. The influence of cisplatin binding on the gas-phase dissociation of nucleic acids was studied by the means of electrospray ionization tandem mass spectrometry. Experiments on native and modified DNA and RNA oligomers confirmed guanine base pairs as the preferred platination site and laid the basis for the formulation of a gas-phase fragmentation mechanism of platinated oligonucleotides. The study was extended to double stranded DNA and DNA quadruplexes. While duplexes are believed to be the main target of cisplatin in vivo, the recently discovered DNA quadruplexes constitute another promising target for anti-tumor drugs owing to their regulatory functions in the cell cycle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Species of the family Pasteurellaceae play an important role as primary or opportunistic, predominantly respiratory, pathogens in domestic and wild animals. Some of them cause severe disease with high economic losses in commercial animal husbandry. Hence, rapid and accurate differentiation of Pasteurellaceae is important and signifies a particular challenge to diagnostic laboratories. Identification and differentiation of Pasteurellaceae is mostly done using phenotypic tests or genetic identification based on sequence similarity of housekeeping genes, such as the rrs gene encoding the 16S ribosomal RNA (16S rRNA). Both approaches are time consuming, laborious, and costly, therefore often delaying the final diagnosis of disease or epidemics. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry represents an alternative rapid and reliable method for the differentiation of most members of the family Pasteurellaceae. It is able to differentiate within a few minutes the currently known 18 genera and most of the over 60 species and subspecies of Pasteurellaceae including many members encountered in veterinary diagnostic laboratories. A few closely related species and subspecies that cannot be discriminated by MALDI-TOF are easily identified further by complementary simple tests, such as hemolysis done simultaneously or routinely during pathogen isolation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous studies of the sediments of Lake Lucerne have shown that massive subaqueous mass movements affecting unconsolidated sediments on lateral slopes are a common process in this lake, and, in view of historical reports describing damaging waves on the lake, it was suggested that tsunamis generated by mass movements represent a considerable natural hazard on the lakeshores. Newly performed numerical simulations combining two-dimensional, depth-averaged models for mass-movement propagation and for tsunami generation, propagation and inunda- tion reproduce a number of reported tsunami effects. Four analysed mass-movement scenarios—three based on documented slope failures involving volumes of 5.5 to 20.8 9 106 m3—show peak wave heights of several metres and maximum runup of 6 to [10 m in the directly affected basins, while effects in neighbouring basins are less drastic. The tsunamis cause large-scale inundation over distances of several hundred metres on flat alluvial plains close to the mass-movement source areas. Basins at the ends of the lake experience regular water-level oscillations with characteristic periods of several minutes. The vulnerability of potentially affected areas has increased dramatically since the times of the damaging historical events, recommending a thorough evaluation of the hazard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A measurement of the mass difference between top and anti-top quarks is presented. In a 4.7 fb−14.7 fb−1 data sample of proton–proton collisions at View the MathML sources=7 TeV recorded with the ATLAS detector at the LHC, events consistent with View the MathML sourcett¯ production and decay into a single charged lepton final state are reconstructed. For each event, the mass difference between the top and anti-top quark candidate is calculated. A two b -tag requirement is used in order to reduce the background contribution. A maximum likelihood fit to these per-event mass differences yields View the MathML sourceΔm≡mt−mt¯=0.67±0.61(stat)±0.41(syst) GeV, consistent with CPT invariance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An autonomous energy source within a human body is of key importance in the development of medical implants. This work deals with the modelling and the validation of an energy harvesting device which converts the myocardial contractions into electrical energy. The mechanism consists of a clockwork from a commercially available wrist watch. We developed a physical model which is able to predict the total amount of energy generated when applying an external excitation. For the validation of the model, a custom-made hexapod robot was used to accelerate the harvesting device along a given trajectory. We applied forward kinematics to determine the actual motion experienced by the harvesting device. The motion provides translational as well as rotational motion information for accurate simulations in three-dimensional space. The physical model could be successfully validated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little is known about the noble gas abundances in comets. These highly volatile atoms are possible tracers of the history of cometary matter including the thermal evolution. They can help quantify the contribution of cometary impacts to terrestrial oceans and help elucidate on the formation history of comets and their role in the formation and evolution of planetary atmospheres. This paper focuses on argon and the capabilities to measure this noble gas with in situ mass spectrometry at comet 67P/Churyumov–Gerasimenko, the target of the European Space Agency׳s spacecraft Rosetta. Argon may have been detected by remote sensing in a single Oort cloud comet but to date nothing is known about the isotopic abundances of argon in comets. Furthermore, no detection of argon in a Jupiter-family comet has been reported. Comet 67P/Churyumov–Gerasimenko belongs to the group of Jupiter-family comets and originates most likely in the Kuiper belt. Onboard Rosetta is ROSINA/DFMS (Rosetta Orbiter Spectrometer for Ion and Neutral Analysis/Double Focusing Mass Spectrometer). DFMS has unprecedented mass resolution and high sensitivity and is designed to measure isotopic ratios including argon (Balsiger et al., 2007). Argon measurements using the DFMS lab model (identical to the flight model) demonstrate this capability. At very least, this mass spectrometer has the resolution and sensitivity to reduce the upper limit on the argon outgassing rate relative to water by more than three orders of magnitude (for 38Ar). Most likely, ROSINA/DFMS will provide the first detection of argon in a Jupiter-family comet together with the first determination of the ³⁶Ar/³⁸Ar ratio at a comet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiocarbon dating by means of accelerator mass spectrometry (AMS) is a well-established method for samples containing carbon in the milligram range. However, the measurement of small samples containing less than 50 lg carbon often fails. It is difficult to graphitise these samples and the preparation is prone to contamination. To avoid graphitisation, a solution can be the direct measurement of carbon dioxide. The MICADAS, the smallest accelerator for radiocarbon dating in Zurich, is equipped with a hybrid Cs sputter ion source. It allows the measurement of both, graphite targets and gaseous CO2 samples, without any rebuilding. This work presents experiences dealing with small samples containing 1-40 lg carbon. 500 unknown samples of different environmental research fields have been measured yet. Most of the samples were measured with the gas ion source. These data are compared with earlier measurements of small graphite samples. The performance of the two different techniques is discussed and main contributions to the blank determined. An analysis of blank and standard data measured within years allowed a quantification of the contamination, which was found to be of the order of 55 ng and 750 ng carbon (50 pMC) for the gaseous and the graphite samples, respectively. For quality control, a number of certified standards were measured using the gas ion source to demonstrate reliability of the data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heating of a pink two-dimensional Co(II) coordination network {[Co2(μ2-OH2)(bdc)2(S-nia)2(H2O)(dmf)]·2(dmf)·(H2O)}n (1) built from 1,4-benzenedicarboxylic acid (H2bdc) residues and thionicotinamide (S-nia) ligands initiates a single-crystal-to-single-crystal transition accompanied by removal of both coordinated and co-crystallized solvents. In the dry blue form, [Co(bdc)(S-nia)]n (dry_1), the Co(II) centers changed from an octahedral to a square pyramidal configuration.