988 resultados para Composite resins


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A process of laser cladding Ni-CF-C-CaF2 mixed powders to form a multifunctional composite coatingd on gamma-TiAl substrate was carried out. The microstructure of the coating was examined using XRD, SEM and EDS. The coating has a unique microstructure consisting of primary dendrite or short-stick TiC and block Al4C3 carbides reinforcement as well as fine isolated spherical CaF2 solid lubrication particles uniformly dispersed in the NiCrAlTi (gamma) matrix. The average microhardness of the composite coatings is approximately HV 650 and it is 2-factor greater than that of the TiAl substrate. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of constitution of precursor mixed powders and scan speed on microstructure and wear properties were designed and investigated during laser clad gamma/Cr7C3/TiC composite coatings on gamma-TiAl intermetallic alloy substrates with NiCr-Cr3C2 precursor mixed powders. The results indicate that both the constitution of the precursor mixed powders and the beam scan rate have remarkable influence on microstructure and attendant hardness as well as wear resistance of the formed composite coatings. The wear mechanisms of the original TiAl alloy and laser clad composite coatings were investigated. The composite coating with an optimum compromise between constitution of NiCr-Cr3C2 precursor mixed powders as well as being processed under moderate scan speed exhibits the best wear resistance under dry sliding wear test conditions. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most space applications require deployable structures due to the limiting size of current launch vehicles. Specifically, payloads in nanosatellites such as CubeSats require very high compaction ratios due to the very limited space available in this typo of platform. Strain-energy-storing deployable structures can be suitable for these applications, but the curvature to which these structures can be folded is limited to the elastic range. Thanks to fiber microbuckling, high-strain composite materials can be folded into much higher curvatures without showing significant damage, which makes them suitable for very high compaction deployable structure applications. However, in applications that require carrying loads in compression, fiber microbuckling also dominates the strength of the material. A good understanding of the strength in compression of high-strain composites is then needed to determine how suitable they are for this type of application.

The goal of this thesis is to investigate, experimentally and numerically, the microbuckling in compression of high-strain composites. Particularly, the behavior in compression of unidirectional carbon fiber reinforced silicone rods (CFRS) is studied. Experimental testing of the compression failure of CFRS rods showed a higher strength in compression than the strength estimated by analytical models, which is unusual in standard polymer composites. This effect, first discovered in the present research, was attributed to the variation in random carbon fiber angles respect to the nominal direction. This is an important effect, as it implies that microbuckling strength might be increased by controlling the fiber angles. With a higher microbuckling strength, high-strain materials could carry loads in compression without reaching microbuckling and therefore be suitable for several space applications.

A finite element model was developed to predict the homogenized stiffness of the CFRS, and the homogenization results were used in another finite element model that simulated a homogenized rod under axial compression. A statistical representation of the fiber angles was implemented in the model. The presence of fiber angles increased the longitudinal shear stiffness of the material, resulting in a higher strength in compression. The simulations showed a large increase of the strength in compression for lower values of the standard deviation of the fiber angle, and a slight decrease of strength in compression for lower values of the mean fiber angle. The strength observed in the experiments was achieved with the minimum local angle standard deviation observed in the CFRS rods, whereas the shear stiffness measured in torsion tests was achieved with the overall fiber angle distribution observed in the CFRS rods.

High strain composites exhibit good bending capabilities, but they tend to be soft out-of-plane. To achieve a higher out-of-plane stiffness, the concept of dual-matrix composites is introduced. Dual-matrix composites are foldable composites which are soft in the crease regions and stiff elsewhere. Previous attempts to fabricate continuous dual-matrix fiber composite shells had limited performance due to excessive resin flow and matrix mixing. An alternative method, presented in this thesis uses UV-cure silicone and fiberglass to avoid these problems. Preliminary experiments on the effect of folding on the out-of-plane stiffness are presented. An application to a conical log-periodic antenna for CubeSats is proposed, using origami-inspired stowing schemes, that allow a conical dual-matrix composite shell to reach very high compaction ratios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of a carbon nanotube microneedle array is explored in this thesis from multiple perspectives including microneedle fabrication, physical aspects of transdermal delivery, and in vivo transdermal drug delivery experiments. Starting with standard techniques in carbon nanotube (CNT) fabrication, including catalyst patterning and chemical vapor deposition, vertically-aligned carbon nanotubes are utilized as a scaffold to define the shape of the hollow microneedle. Passive, scalable techniques based on capillary action and unique photolithographic methods are utilized to produce a CNT-polymer composite microneedle. Specific examples of CNT-polyimide and CNT-epoxy microneedles are investigated. Further analysis of the transport properties of polymer resins reveals general requirements for applying arbitrary polymers to the fabrication process.

The bottom-up fabrication approach embodied by vertically-aligned carbon nanotubes allows for more direct construction of complex high-aspect ratio features than standard top-down fabrication approaches, making microneedles an ideal application for CNTs. However, current vertically-aligned CNT fabrication techniques only allow for the production of extruded geometries with a constant cross-sectional area, such as cylinders. To rectify this limitation, isotropic oxygen etching is introduced as a novel fabrication technique to create true 3D CNT geometry. Oxygen etching is utilized to create a conical geometry from a cylindrical CNT structure as well as create complex shape transformations in other CNT geometries.

CNT-polymer composite microneedles are anchored onto a common polymer base less than 50 µm thick, which allows for the microneedles to be incorporated into multiple drug delivery platforms, including modified hypodermic syringes and silicone skin patches. Cylindrical microneedles are fabricated with 100 µm outer diameter and height of 200-250 µm with a central cavity, or lumen, diameter of 30 µm to facilitate liquid drug flow. In vitro delivery experiments in swine skin demonstrate the ability of the microneedles to successfully penetrate the skin and deliver aqueous solutions.

An in vivo study was performed to assess the ability of the CNT-polymer microneedles to deliver drugs transdermally. CNT-polymer microneedles are attached to a hand actuated silicone skin patch that holds a liquid reservoir of drugs. Fentanyl, a potent analgesic, was administered to New Zealand White Rabbits through 3 routes of delivery: topical patch, CNT-polymer microneedles, and subcutaneous hypodermic injection. Results demonstrate that the CNT-polymer microneedles have a similar onset of action as the topical patch. CNT-polymer microneedles were also vetted as a painless delivery approach compared to hypodermic injection. Comparative analysis with contemporary microneedle designs demonstrates that the delivery achieved through CNT-polymer microneedles is akin to current hollow microneedle architectures. The inherent advantage of applying a bottom-up fabrication approach alongside similar delivery performance to contemporary microneedle designs demonstrates that the CNT-polymer composite microneedle is a viable architecture in the emerging field of painless transdermal delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part I. Novel composite polyelectrolyte materials were developed that exhibit desirable charge propagation and ion-retention properties. The morphology of electrode coatings cast from these materials was shown to be more important for its electrochemical behavior than its chemical composition.

Part II. The Wilhelmy plate technique for measuring dynamic surface tension was extended to electrified liquid-liquid interphases. The dynamical response of the aqueous NaF-mercury electrified interphase was examined by concomitant measurement of surface tension, current, and applied electrostatic potential. Observations of the surface tension response to linear sweep voltammetry and to step function perturbations in the applied electrostatic potential (e.g., chronotensiometry) provided strong evidence that relaxation processes proceed for time-periods that are at least an order of magnitude longer than the time periods necessary to establish diffusion equilibrium. The dynamical response of the surface tension is analyzed within the context of non-equilibrium thermodynamics and a kinetic model that requires three simultaneous first order processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na Odontologia, ao se confeccionar peças restauradoras dentárias, pela técnica indireta, o processo mais rotineiramente empregado utiliza um modelo de gesso, obtido a partir de um molde de elastômero, tomado de um dente preparado. Vários fatores podem influenciar na boa precisão de ajustes destas peças como o escoamento do material de vazamento dentro da moldagem, a compatibilidade do material de vazamento com o da moldagem, o tempo de presa, a estabilidade dimensional, a resistência mecânica do material quando da separação moldagem/modelo, a resistência a abrasão e a fidelidade de reprodução de detalhes. Materiais foram introduzidos na odontologia para utilização na confecção de troquéis no intuito de minimizar as desvantagens do gesso, como baixa resistência a abrasão e ligeira expansão de presa. Dentre eles os troquéis metalizados e as resinas epóxicas, que tem vantagens em relação às propriedades mecânicas, porém o primeiro exige técnica demorada e de alto custo e o segundo apresenta contração. O presente trabalho se propõe a testar uma nova composição de poliéster insaturado com estireno adicionado ao carbonato de cálcio em diferentes proporções (10, 20, 30, 40, 50, 60 e 70%) e compará-la ao gesso tipo IV e a resina epoxídica com óxido de alumínio, através de ensaios mecânicos, de abrasão e de alteração dimensional, para avaliar a possibilidade de sua utilização como material de confecção de troquéis para a construção de restaurações indiretas. Para caracterização dos materiais foram feitas análises de espectrometria no infravermelho, Calorimetria de varredura diferencial, termogravimétrica e Microscopia eletrônica de varredura. O compósito a base de poliéster insaturado com 50% de carbonato de cálcio se mostrou viável para utilização como material para troquel. Quando comparado aos materiais de controle mostrou propriedades mecânicas próximas as da resina epoxídica e bem superiores ao gesso, resistência a abrasão superior ao gesso e inferior a resina epoxídica e alteração dimensional próxima a resina epoxídica e maior ao gesso. Sendo a formulação do poliéster/carbonato de cálcio apenas constituída de polímero, catalisador e carga, é possível melhorar a formulação modificando a carga e/ou acrescentando aditivos visando minimizar a contração de polimerização.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nesta dissertação, duas resinas reticuladas comerciais (denominadas, AmberliteGT73 e AmberliteIRC748) foram empregadas para suportar partículas de prata. Os grupos tiol da GT73 e ácido iminodiacético da IRC748 presentes nessas resinas foram empregados para a fixação de íons Ag+ a partir de solução aquosa. Posteriormente, os íons Ag+ foram reduzidos pelo emprego de três redutores diferentes em pH alcalino, denominados hidrazina, hidroxilamina e formaldeído (pH  12). A morfologia e a impregnação de prata dos materiais binários assim obtidos foram avaliadas por meio de microscópio eletrônico de varredura equipado com detector de elétrons retro-espalhados (SEM-BSE). O detector de espectrometria de energia dispersiva de raios-X (EDAX) acoplado ao SEM permitiu a observação de partículas de prata. Os espectros de raios-X revelaram a presença do metal nas superfícies interna e externa das microesferas dos compósitos. A quantidade de prata incorporada foi determinada pelo método titulométrico, empregando solução padrão de tiocianato de potássio. As características antibactericidas dos compósitos foram avaliadas em colunas contendo pérolas de resina por onde foram percoladas suspensões da bactéria Escherichia coli auxotrópica AB1157 (tipo selvagem) nas concentrações de 103 a 107 células/mL. A avaliação biocida mostrou que estes materiais foram completamente bactericidas, sendo efetivos na eliminação da bactéria em poucos minutos. Esta ação biocida foi atribuída à combinação da atuação da prata e dos grupos funcionais das resinas