992 resultados para Cochlear implantation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Personalized tissue engineering and regenerative medicine (TERM) therapies propose patient-oriented effective solutions, considering individual needs. Cell-based therapies, for example, may benefit from cell sources that enable easier autologous set-ups or from recent developments on IPS cells technologies towards effective personalized therapeutics. Furthermore, the customization of scaffold materials to perfectly fit a patientâ s tissue defect through rapid prototyping technologies, also known as 3D printing, is now a reality. Nevertheless, the timing to expand cells or to obtain functional in vitrotissue substitutes prior to implantation prevents advancements towards routine use upon patient´s needs. Thus, personalized therapies also anticipate the importance of creating off-the-shelf solutions to enable immediately available tissue engineered products. This paper reviews the main recent developments and future challenges to enable personalized TERM approaches and to bring these technologies closer to clinical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Evaluation of the role of transesophageal echocardiography in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Patients were selected for percutaneous closure of ASD by transesophageal echocardiography (TEE), which was also used to monitor the procedure, helping to select the appropriate size of the Amplatzer device, to verify its position, and to access the immediate results of the procedure. During the follow-up, TEE was used to evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiac chamber diameters. RESULTS: Twenty-two (40%) of a total of 55 studied patients were selected. Thirteen underwent Amplatzer device implantation, eight are still waiting for it, and one preferred the conventional surgical treatment. All procedures were successful, which was mainly due to proper patient selection. Six (23%) patients acutely developed RS, which spontaneously disapeared at the three-month follow-up examination in three patients. There was a significant reduction in the right ventricle diastolic diameter, from 27mm (average) to 24mm and 20mm, one and three months after the procedure, respectively (p<0.0076). CONCLUSION: With the aid of TEE, percutaneous closure of ASD can be successfully, safely, and effectively performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To report the authors' experience with the anomalous origin of the left coronary artery (AOLCA) from the pulmonary trunk, emphasizing preoperative data, surgical aspects and midterm results of the follow-up. METHODS: Retrospective analysis of 11 patients operated upon at the Royal Brompton Hospital from October, 84 to April, 97. RESULTS: Nine infants had heart failure (HF) and two other children presented with dyspnea and chest pain. All had ECG changes. The echocardiogram identified the anomalous origin of the coronary artery in 7 (64%) patients and hemodynamic studies were performed in 7 patients. All infants were operated upon between the 2nd and 10th month of life. Six patients were treated with aortic reimplantation of the left coronary artery, whereas five were operated upon according to the Takeuchi technique. All patients are alive, with clear improvement of the ECG changes and ventricular function, as evaluated by echocardiography. Two patients operated upon according to the Takeuchi technique required additional surgery due to severe supravalvular pulmonary stenosis. CONCLUSION: AOLCA is a rare disease. Most patients show early signs of severe HF associated with ECG findings. Surgical therapy must be instituted early in the disease, preferentially through aortic implantation of the anomalous coronary artery, with a high possibility of success. Shortly after surgery, clinical and ECG improvement, as well as normalization of left ventricular function, should be expected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the changes in ventricular evoked responses (VER) produced by the decrease in left ventricular outflow tract gradient (LVOTG) in patients with hypertrophic obstructive cardiomyopathy (HOCM) treated with dual-chamber (DDD) pacing. METHODS: A pulse generator Physios CTM (Biotronik, Germany) was implanted in 9 patients with severe drug-refractory HOCM. After implantation, the following conditions were assessed: 1) Baseline evaluation: different AV delay (ranging from 150ms to 50 ms) were sequentially programmed during 5 to 10 minutes, and the LVOTG (as determined by Doppler echocardiography) and VER recorded; 2) standard evaluation, when the best AV delay (resulting in the lowest LVOTG) programmed at the initial evaluation was maintained so that its effect on VER and LVOTG could be assessed during each chronic pacing evaluation. RESULTS: LVOTG decreased after DDD pacing, with a mean value of 59 ± 24 mmHg after dual chamber pacemaker, which was significantly less than the gradient before pacing (98 + 22mmHg). An AV delay >100ms produced a significantly lower decrease in VER depolarization duration (VER DD) when compared to an AV delay <=100ms. Linear regression analyses showed a significant correlation between the LVOTG values and the magnitude of VER (r=0.69; p<0.05) in the 9 studied patients. CONCLUSION: The telemetry obtained intramyocardial electrogram is a sensitive means to assess left ventricular dynamics in patients with HOCM treated with DDD pacing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE - This study compared the early and late results of the use of one single stent with those of the use of multiple stents in patients with lesions longer than 20mm. METHODS - Prospective assessment of patients electively treated with stents, with optimal stent deployment and followed-up for more than 3 months. From February '94 to January '98, 215 patients with lesions >20mm were treated. These patients were divided into 2 groups as follows: Group A - 105 patients (49%) with one stent implanted; Group B - 110 patients (51%) with multiple stents implanted. RESULTS - The mean length of the lesions was 26mm in group A (21-48mm) versus 29mm in group B (21-52mm) (p=0.01). Major complications occurred in one patient (0.9%) in group A (subacute thrombosis, myocardial infarctionand death) and in 2 patients (1.8%) in group B (one emergency surgery and one myocardial infarction) (p=NS). The results of the late follow-up period (>6 months) were similar for both groups (group A = 82% vs group B = 76%; p=NS), and we observed an event-free survical in 89% of the patients in group A and in 91% of the patients in group B (p=NS). Angina (group A = 11% vs group B = 7%) and lesion revascularization (group A = 5% vs group B = 6%; p=NS) also occurred in a similar percentage. No infarction or death was observed in the late follow-up period; restenosis was identified in 33% and 29% of the patients in groups A and B, respectively (p=NS). CONCLUSION - The results obtained using one stent and using multiple stents were similar; the greater cost-effectiveness of one stent implantation, however, seems to make this strategy the first choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the early outcome of mitral valve prostheses implantation and left ventricular remodeling in 23 patients with end-stage cardiomyopathy and secondary mitral regurgitation (NYHA class III and IV). METHODS: Mitral valvular prosthesis implantation with preservation of papillary muscles and chordae tendinae, and plasty of anteriun cuspid for remodeling of the left ventricle. RESULTS: The surgery was performed in 23 patients, preoperative ejection fraction (echocardiography) varied from 13% to 44% (median: 30%). In 13 patients associated procedures were performed: myocardial revascularization (9), left ventricle plicature repair (3) and aortic prosthese implantation (1). Early deaths (2) occurred on the 4th PO day (cardiogenic shock) and on the 20th PO day (upper gastrointestinal bleeding), and a late death in the second month PO (ventricular arrhythmia). Improvement occurred in NYHA class in 82.6% of the patients (P<0.0001), with a survival rate of 86.9% (mean of 8.9 months of follow-up). CONCLUSION: This technique offers a promising therapeutic alternative for the treatment of patients in refractory heart failure with cardiomyopathy and secondary mitral regurgitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare the outcome of balloon PTCA with final coronary stenosis diameter (SD) <=30%, with elective coronary stenting. METHODS: We performed a comparative analysis of the 6 month outcomes in patients treated with primary stenting and those who obtained an optimal balloon PTCA result treated during the first 12 hours of AMI onset included in the STENT PAMI randomized trial. RESULTS: The results were analysed into 3 groups: primary stenting (441 patients, SD=22±6%), optimal PTCA (245 patients), and nonoptimal PTCA (182 patients, SD= 37±5%). At the end of the 6 months primary stent group presented with the lowest restenosis(23 vs. 31 vs. 45%, p=0.001, respectively). Ischemia-driven target vessel revascularization rate (TVR) (7 vs. 15.5 vs. 19%, p=0.001, respectively). CONCLUSION: At the 6 month follow-up, primary stenting offered the lowest restenosis and ischemia-driven TVR rates. Compared to optimal balloon PTCA. Nonoptimal primary balloon PTCA pts (SD=31-50%), had the worst late angiographic outcomes and should be treated more actively with coronary stent implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Analysis of the in-hospital results, in progressively elderly patients who undergo primary percutaneous coronary intervention (PCI) in the first 24 hours of AMI. METHODS: The patients were divided into three different age groups (60/69, 70/79, and > or = 80 years) and were treated from 7/95 until 12/99. The primary success rate and the occurrence of major clinical events were analyzed at the end of the in-hospital phase. Coronary stent implantation and abciximab use were employed at the intervencionist discretion. RESULTS: We analyzed 201 patients with age ranging from 60 to 93 years, who underwent primary PCI. Patients with ages above 70 were more often female (p=.015). Those with ages above 80 were treated later with PCI (p=.054), and all of them presented with total occlusion of the infarct-related artery. Coronary stents were implanted in 30% of the patients. Procedural success was lower in > or = 80 year old patients (p=.022), and the death rate was higher in > or = 70 years olds (p=.019). Reinfarction and coronary bypass surgery were uncommon events. A trend occurred toward a higher combined incidence of major in-hospital events according to increased age (p=.064). CONCLUSION: Elderly patients ( > or = 70 years) presented with adverse clinical and angiographic profiles and patients > or = 80 years of age obtained reduced TIMI 3 flow success rates after primary PTCA, and those > or = 70 years had a higher death rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study was performed to observe the number of pacemakers that had never been reprogrammed after implantation, and the effect of optimised output programming on estimated longevity of pulse generators in patients with pacemaker METHODS: Sixty patients with Teletronics Reflex pacemakers were evaluated in a pacemaker clinic, from the time of the beginning of its activities, in June 1998, until March 1999. Telemetry was performed during the first clinic visit, and we observed how many pulse generators retained nominal output settings of the manufactures indicating the absence of reprogramming until that date. After evaluation of the capture threshold, reprogramming of pacemakers was performed with a safety margin of 2 to 2.5:1, and we compared the estimated longevity based on battery current at the manufacturer's settings with that based on settings achieved after reprogramming. RESULTS: In 95% of the cases, the original programmed setting was never reprogrammed before the patients attended the pacemaker clinic. Reprogramming the pacemaker prolonged estimated pulse generator life by 19.7±15.6 months (35.5%). CONCLUSION: The majority of the pacemakers evaluated had never been reprogrammed. Estimated pulse generator longevity can be prolonged significantly, using this simple, safe, efficacious, and cost-effective procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA) or stent implantation because of an acute myocardial infarction (AMI) related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC). From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3%) of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47%) patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The patient is a 54-year-old asymptomatic male with a tumor in the right atrium that was diagnosed on transesophageal echocardiography and confirmed as a lipoma of the right atrium on computerized tomography. The patient underwent surgical repair with extracorporeal circulation. The tumor was resected, and its base of implantation in the atrium was repaired with a flap of bovine pericardium. The diagnosis of lipoma was confirmed on histopathological examination. Locating of the tumor with the aid of transesophageal echocardiography was very useful in the strategy of cannulation of the venae cava for installation of the circuit of extracorporeal circulation. The patient had a good postoperative evolution.