952 resultados para Basal-plane
Resumo:
Ethanol-dependent individuals who reduce or discontinue its use may present Alcohol Withdrawal Syndrome, which is characterized by unpleasant signs and symptoms, such as anxiety, that may trigger relapses. Ethanol, a psychotropic drug, is able to promote behavioral and neurophysiological changes, acting on different neurotransmitter systems, including the serotonergic, which has also been directly associated with aversive states, including anxiety. This study aimed to investigate the participation of type 7 serotonin receptor (5-HT7) of the dorsal periaqueductal gray (DPAG) on basal experimental anxiety and that caused by ethanol withdrawal. For this, 75-100 days old Wistar rats were subjected to two experiments. On the first one, animals underwent stereotactic surgery for implantation of guide cannulas used for administration of the drug directly into the DPAG. After seven days, the animals received doses of 2.5; 5 and 10 nmols of type 7 receptor antagonist SB269970 (SB) or vehicle intra-DPAG and, ten minutes after, they were exposed to elevated plus maze (EPM). In the following day, the animals were submitted to the same treatment and tested in the open field (OF). In the second experiment, animals received increasing concentrations (2%, 4%, 6%) of ethanol as the only source of liquid diet or water (control group), both with free access to chow. Seventy two hours and ninety six hours after the ethanol withdrawal, animals received SB (2.5 and 5.0 nmols) intraDPAG ten minutes before the test in the LCE and OF, respectively. In experiment 1, the dose of antagonist 10 nmols was able of reversing the anxiety generated by EPM. In the experiment 2, ineffective SB doses on the LCE (2.5 and 5.0 nmol) were not able to reverse the anxiety caused by the ethanol withdrawal in the EPM, although the dose of 2.5 nmols of SB has reversed its hipolocomotor effect in this test. This result suggests that the 5-HT7 receptor is involved in the modulation of the basal experimental anxiety in rats, but not in the anxiety caused by ethanol withdrawal in the DPAG.
Resumo:
This dissertation presents a calibration procedure for a pressure velocity probe. The dissertation is divided into four main chapters. The first chapter is divided into six main sections. In the firsts two, the wave equation in fluids and the velocity of sound in gases are calculated, the third section contains a general solution of the wave equation in the case of plane acoustic waves. Section four and five report the definition of the acoustic impedance and admittance, and the practical units the sound level is measured with, i.e. the decibel scale. Finally, the last section of the chapter is about the theory linked to the frequency analysis of a sound wave and includes the analysis of sound in bands and the discrete Fourier analysis, with the definition of some important functions. The second chapter describes different reference field calibration procedures that are used to calibrate the P-V probes, between them the progressive plane wave method, which is that has been used in this work. Finally, the last section of the chapter contains a description of the working principles of the two transducers that have been used, with a focus on the velocity one. The third chapter of the dissertation is devoted to the explanation of the calibration set up and the instruments used for the data acquisition and analysis. Since software routines were extremely important, this chapter includes a dedicated section on them and the proprietary routines most used are thoroughly explained. Finally, there is the description of the work that has been done, which is identified with three different phases, where the data acquired and the results obtained are presented. All the graphs and data reported were obtained through the Matlab® routine. As for the last chapter, it briefly presents all the work that has been done as well as an excursus on a new probe and on the way the procedure implemented in this dissertation could be applied in the case of a general field.
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Unacylated ghrelin (UAG) is the predominant ghrelin isoform in the circulation. Despite its inability to activate the classical ghrelin receptor, preclinical studies suggest that UAG may promote β-cell function. We hypothesized that UAG would oppose the effects of acylated ghrelin (AG) on insulin secretion and glucose tolerance. AG (1 µg/kg/h), UAG (4 µg/kg/h), combined AG+UAG, or saline were infused to 17 healthy subjects (9 men and 8 women) on four occasions in randomized order. Ghrelin was infused for 30 min to achieve steady-state levels and continued through a 3-h intravenous glucose tolerance test. The acute insulin response to glucose (AIRg), insulin sensitivity index (SI), disposition index (DI), and intravenous glucose tolerance (kg) were compared for each subject during the four infusions. AG infusion raised fasting glucose levels but had no effect on fasting plasma insulin. Compared with the saline control, AG and AG+UAG both decreased AIRg, but UAG alone had no effect. SI did not differ among the treatments. AG, but not UAG, reduced DI and kg and increased plasma growth hormone. UAG did not alter growth hormone, cortisol, glucagon, or free fatty acid levels. UAG selectively decreased glucose and fructose consumption compared with the other treatments. In contrast to previous reports, acute administration of UAG does not have independent effects on glucose tolerance or β-cell function and neither augments nor antagonizes the effects of AG.
Resumo:
Travaux d'études doctorales réalisées conjointement avec les travaux de recherches doctorales de Nicolas Leduc, étudiant au doctorat en génie informatique à l'École Polytechnique de Montréal.
Resumo:
Aims The pubococcygeal line (PCL) is an important reference line for determining measures of pelvic organ support on sagittal-plane magnetic resonance imaging (MRI); however, there is no consensus on where to place the posterior point of the PCL. As coccyx movement produced during pelvic floor muscle (PFM) contractions may affect other measures, optimal placement of the posterior point is important. This study compared two methods for measuring the PCL, with different posterior points, on T2-weighted sagittal MRI to determine the effect of coccygeal movement on measures of pelvic organ support in older women. Methods MRI of the pelvis was performed in the midsagittal plane, at rest and during PFM contractions, on 47 community-dwelling women 60 and over. The first PCL was measured to the tip of the coccyx (PCLtip) and the second to the sacrococcygeal joint (PCLjnt). Four measures of pelvic organ support were made using each PCL as the reference line: urethrovesical junction height, uterovaginal junction height, M-line and levator plate angle. Results During the PFM contraction the PCLtip shortened and lifted (P < 0.001); the PCLjnt did not change (P > 0.05). The changes in the four measures of pelvic organ support were smaller when measured relative to the PCLtip as compared to those to the PCLjnt (P < 0.001). Conclusions Coccyx movement affected the length and position of the PCLtip, which resulted in underestimates of the pelvic-organ lift produced by the PFM contraction. Therefore, we recommend that the PCL be measured to the sacrococcygeal joint and not to the tip of the coccyx
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
This paper presents novel ultra-compact waveguide bandpass filters that exhibit pseudo elliptic responses with ability to place transmission zeros on both sides of the passband to form sharp roll offs. The filters contain E plane extracted pole sections cascaded with cross-coupled filtering blocks. Compactness is achieved by the use of evanescent mode sections and closer arranged resonators modified to shrink in size. The filters containing non-resonating nodes are designed by means of the generalized coupling coefficients (GCC) extraction procedure for the cross-coupled filtering blocks and extracted pole sections. We illustrate the performance of the proposed structures through the design examples of a third and a fourth order filters with center frequencies of 9.2 GHz and 10 GHz respectively. The sizes of the proposed structures suitable for fabricating using the low cost E plane waveguide technology are 38% smaller than ones of the E plane extracted pole filter of the same order.